S'abonner

Clinical and radiological outcomes with the Durom™ acetabular cup for large-diameter total hip arthroplasty: 177 implants after a mean of 80 months - 21/05/15

Doi : 10.1016/j.otsr.2015.02.008 
D. Saragaglia , B. Belvisi, B. Rubens-Duval, R. Pailhé, R.C. Rouchy, R. Mader
 Clinique universitaire de chirurgie orthopédique et de traumatologie du sport, hôpital Sud, CHU de Grenoble, avenue de Kimberley, BP 338, 38130 Échirolles, France 

Corresponding author. Tel.: +33 476 765 434.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Large-diameter metal-on-metal hip prostheses are no longer used, but their outcomes after more than 5years are unknown. We conducted a retrospective study with a 6.8-year mean follow-up to assess clinical outcomes after Durom™ cup implantation, including the dislocation rate, comparatively to the reference metal-on-polyethylene bearing. We determined the rate of failure ascribable to Durom™ cup use. We also looked for a sharp drop in the implant survival curve during the follow-up period and for factors associated with adverse reactions to metal debris (ARMDs).

Hypothesis

We hypothesised that clinical outcomes after Durom™ cup implantation were similar to those seen with a metal-on-polyethylene bearing, except for a lower rate of dislocation.

Patients and methods

We included 177 consecutive THA procedures that were performed between 2005 and 2008 in 165 patients with a mean age of 57.6±9.4years (range, 31–76years) and involved the implantation of a Durom™ cup, a femoral head greater than 36mm in diameter, and a PF® femoral stem (Zimmer, Etupes, France). The mini-posterior approach was used, with 2mm of acetabular overreaming in 82% of cases, a short femoral neck in 75% of cases, and a mean cup inclination of 34±5° (range, 21–50°).

Results

Outcomes were assessed for 156 THA procedures in 146 patients after a mean follow-up of 6years 8months. The mean Postel-Merle d’Aubigné score improved from 9.7±2.7 (range, 4–14) to 17.4±1.7 (range, 15–18) and the mean Harris hip score from 45.2±15.3 (range, 9–83) to 96.3±7 (75–100). No episodes of dislocation were recorded. We identified 7 failures ascribable to the Durom™ cup including 6 due to ARMD and 1 to aseptic loosening. Implant survival after a mean of 80months was 95.5% (95% CI, 93.1–99.2), with no sharp drop in the survival curve.

Conclusion

The Durom™ cup eliminates the risk of hip dislocation and produces similar functional outcomes to those seen with metal-on-polyethylene bearings after a mean follow-up of 80months. Nevertheless, given the difficulty in predicting ARMD and hypersensitivity reactions, the Durom™ cup has been discarded and patients carrying it are monitored closely.

Level of evidence

IV, retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Metal-on-metal, Large-diameter head, Total hip arthroplasty, Durom™


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 4

P. 437-441 - juin 2015 Retour au numéro
Article précédent Article précédent
  • Is there any advantage in placing an additional calcar screw in locked nailing of proximal humeral fractures?
  • J.C. Katthagen, M. Schwarze, L. Bauer, J. Meyer-Kobbe, C. Voigt, C. Hurschler, H. Lill
| Article suivant Article suivant
  • Sulcus deepening trochleoplasty for patellofemoral instability: A series of 34 cases after 15 years postoperative follow-up
  • T. Rouanet, F. Gougeon, J.M. Fayard, F. Rémy, H. Migaud, G. Pasquier

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.