Abstract

Purpose

In revision anterior cruciate ligament reconstruction (ACLR), the single-stage technique and the over-the-top route (OTTR) procedure were usually selected for cases where the bone tunnel cannot be created at an anatomical position due to tunnel enlargement and overlap with the mal-positioned tunnel of primary reconstruction. The purpose of this study was to evaluate the clinical results of revision single-bundle ACL reconstruction using OTTR procedure and to compare the clinical results of OTTR procedure with those of anatomical single-bundle revision reconstruction (SBR).

Hypothesis

The results of OTTR procedure are equivalent to that of SBR.

Methods

Seventy-six revision ACL reconstruction knees from April 2002 to December 2012 were involved in our study. We focused on 21 knees which underwent surgery with SBR and 22 knees with OTTR using hamstring tendon. The clinical results were evaluated by means of the Lysholm score and the knee stability was assessed by the Lachman test, pivot-shift test and side-to-side difference by KT-2000 pre-operatively and after 1 year post-operatively. AP translation and rotational laxity using a navigation system were evaluated before and after revision ACL reconstruction under anesthesia in 8 cases of OTTR and in 6 cases of SBR.

Results

There was no statistically significant difference between the OTTR and SBR regarding Lysholm score, Lachman test, pivot-shift test, ATT by KT-2000, and AP translation and rotational laxity with a navigation system.

Conclusions

The clinical results of OTTR are almost equivalent to those of SBR. For the cases in which it is impossible to create the femoral tunnel in an anatomical position, OTTR is a valuable revision ACL reconstruction method.

Level of evidence

Case-control study. Level III.

Le texte complet de cet article est disponible en PDF.

Keywords : Revision anterior cruciate ligament reconstruction, Over-the-top procedure, Single-bundle, Knee stability


Plan


© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 1

P. 71-75 - février 2015 Retour au numéro
Article précédent Article précédent
  • Medial patellofemoral ligament reconstruction: Clinical and radiographic results in a series of 90 cases
  • T. Neri, R. Philippot, O. Carnesecchi, B. Boyer, F. Farizon
| Article suivant Article suivant
  • Surgical management of knee dislocations with ligament reconstruction associated with a hinged external fixator
  • F.J. Angelini, C.P. Helito, M.B. Bonadio, R.F. da Mota e Albuquerque, J.R. Pecora, G.L. Camanho

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.