Abstract

Introduction

In some clinical situations such as when the Long Head of the Biceps (LHB) is unstable or with an “hourglass biceps”, treatment is required. Tenodesis is an alternative to tenotomy to prevent the Popeye sign. Although sutures, anchors or interference screws may be used, they all have complications and drawbacks. Moreover, the number of failures is underestimated because it only considers the visible deformities of the arm. MRI provides more accurate assessment, but is more expensive. We hypothesized that Froimson's “keyhole technique” which has been described in open surgery could be performed arthroscopically with similar clinical outcomes to conventional techniques and without the complications or drawbacks. We also propose an objective and less expensive assessment of treatment failure.

Materials and methods

This 12-month prospective study was performed by a single surgeon. All patients requiring LHB tenodesis underwent arthroscopic “keyhole technique” surgery performed at the upper edge of the Pectoralis major in the bicipital groove. The LHB was externalised, pulled back on itself and the intra-articular portion was resected. A metal marker was placed in the tendon. The latter was introduced into the keyhole and hangs spontaneously. The follow-up evaluation was performed during the third month with a clinical examination and a plain X-ray. Distal migration of the metal marker was the sign of the failure of tenodesis.

Results

Between January 1st and December 31st, 2013, 123 patients were included. There were 87 men (70.7%) and 36 women (29.3%) and mean age was 52.2 (27–71). Eighty-eight patients underwent arthroscopic rotator cuff repair. Twenty-three patients (18.5%) had tenodesis failure shown by distal migration of the metal marker on plain X-rays. There were 21 men and 2 women. Only 13 had a visible Popeye sign and 1 was severe. None of the patients felt any discomfort, fatigue or painful cramping. There was no difference in flexion and supination strength from the healthy side. No complications were noted.

Discussion and conclusion

We confirm the hypothesis that this arthroscopic technique is feasible and reproducible with clinical outcomes similar to conventional techniques but without the complications. The metal marker implanted in the LHB confirms the exact number of failures, which is a significant element in this study.

Level of evidence

IV.

Le texte complet de cet article est disponible en PDF.

Keywords : Biceps, Tenodesis, Arthroscopy, Keyhole, SLAP lesion


Plan


© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 1

P. 31-34 - février 2015 Retour au numéro
Article précédent Article précédent
  • Finite element analysis of posterior cervical fixation
  • Y. Duan, H.H. Wang, A.M. Jin, L. Zhang, S.X. Min, C.L. Liu, S.J. Qiu, X.Q. Shu
| Article suivant Article suivant
  • Open Latarjet procedure for failed arthroscopic Bankart repair
  • T. Flinkkilä, K. Sirniö

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.