S'abonner

Protocole donneur unique : pratiques transfusionnelles et facteurs de risque des transfusions multiples en réanimation néonatale - 16/08/16

Doi : 10.1016/j.arcped.2016.06.006 
C. Dollat a, , C. Pierron a, A. Keslick a, E. Billoir b, A. François c, P.-.H. Jarreau a
a DHU « risques et grossesse », service de médecine et réanimation néonatales de Port-Royal, université Paris Descartes, 53, avenue de l’Observatoire, 75679 Paris, France 
b CNRS UMR 7360 (LIEC), université de Lorraine, 8, rue du Général-Delestraint, 57070 Metz, France 
c Site transfusionnel de l’HEGP EFS Île-de-France, 20, rue Leblanc, 75015 Paris, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 4
Vidéos 0
Autres 0

Résumé

Le protocole donneur unique (PDU) pour la transfusion en culots globulaires consiste en l’attribution à un enfant de 4 unités pédiatriques issues d’un même don de sang. Son utilisation est recommandée pour les nouveau-nés prématurés afin de diminuer les risques infectieux et d’allo-immunisation. Cependant, il conduit à la transfusion de sang stocké, dont certaines études remettent en cause l’innocuité. À la veille des nouvelles recommandations de la Haute Autorité de santé en 2015, nous avons effectué une enquête nationale de pratique auprès des réanimations néonatales afin d’évaluer l’utilisation du PDU ainsi qu’une étude des caractéristiques des enfants transfusés au sein de notre unité afin de mieux en identifier les bénéficiaires. L’enquête de pratique a révélé que 30 % des réanimations néonatales ne l’utilisaient plus en 2014, en raison de problèmes logistiques, financiers ou d’inquiétudes face à la transfusion de sang stocké. Dans notre unité, le PDU entraînait l’utilisation de sang stocké depuis plus de 20jours dans la moitié des cas à partir de la 3e unité transfusée. Deux facteurs étaient prédictifs de polytransfusion : la faiblesse du terme de naissance et la hauteur du score Clinical Risk Index for Babies (CRIB). Ces variables intégrées dans un modèle statistique permettaient de prédire le risque de polytransfusion. D’après ce modèle, un seuil de 50 % de risque de polytransfusion permet de cibler au mieux les enfants devant bénéficier d’un PDU en limitant le nombre de poches utilisées.

Le texte complet de cet article est disponible en PDF.

Summary

In France since 2002, the single-donor transfusion protocol, using four pediatric units from the same adult donor's packed red blood cells (PRBCs) in multiply transfused newborns, is recommended in preterm neonates to reduce the risks of infection and alloimmunization. This protocol is controversial, however, because it causes the transfusion of stored blood, which could have adverse consequences. Before the new recommendations of the French Haute Autorité de santé (National authority for health) in 2015, we conducted a national practice survey in 63 neonatal intensive care units (NICU) and a retrospective study of the characteristics of 103 children transfused within our unit, to better target beneficiaries. The practice survey showed that 30 % of French NICUs no longer used the protocol in 2014, due to logistical or financial problems, or concerns about the transfusion of stored blood. The practices were heterogeneous. Few NICUs used a written protocol. In our NICU, the use of single-donor protocol involved the use of units stored for more than 20 days in half of the cases beginning with the third unit used. Six-term newborns were mainly transfused once, which does not seem to warrant the single-donor transfusion protocol. The use of this protocol caused the loss of 50 % of the manufactured units, which go unused. In multivariate analysis, two factors were predictive of multiple transfusion within our population of 95 premature neonates undergoing transfusion: low-term and a high Clinical Risk Index for Babies (CRIB) score. The risk of multiple transfusions would be reduced by about 15 % for each additional week of gestation and approximately 16 % per point within the CRIB score. These variables integrated into a statistical model predict the risk of multiplying transfusions. According to the ROC curve, a calculated risk higher than 50 % is the appropriate cut-off value to transfuse with the single-donor transfusion protocol. This would limit its indications, saving more than 130 pediatric units of blood for 100 transfused children. A prospective study in our department will allow internal validation of this test.

Le texte complet de cet article est disponible en PDF.

Plan


© 2016  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 23 - N° 9

P. 935-943 - septembre 2016 Retour au numéro
Article précédent Article précédent
  • Devenir à l’âge de 3 ans d’une cohorte d’enfants nés à moins de 26 semaines d’aménorrhée
  • O. Delmas, P. Garcia, V. Bernard, M. Fabre, R. Vialet, F. Boubred, L. Fayol
| Article suivant Article suivant
  • Limit of viability: The Swiss experience
  • T.M. Berger, M. Roth-Kleiner

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.