Volume 110, n° 11
pages 580-589 (novembre 2017)
Doi : 10.1016/j.acvd.2016.12.015
Received : 29 August 2016 ;  accepted : 21 December 2016
Performance of new automated transthoracic three-dimensional echocardiographic software for left ventricular volumes and function assessment in routine clinical practice: Comparison with 3 Tesla cardiac magnetic resonance
Performance d’un nouveau logiciel automatisé d’évaluation des volumes et de la fonction ventriculaire gauches en échocardiographie tridimensionnelle transthoracique en routine clinique. Comparaison avec l’IRM cardiaque 3 Tesla
 
(515 Ko)
 Supplementary Figure 1 
Supplementary Figure 1. 

A. Left ventricular end-diastolic volume (EDV). B. Left ventricular end-systolic volume (ESV). C. Left ventricular ejection fraction (EF), using different methods: two-dimensional transthoracic echocardiography (2D); three-dimensional transthoracic echocardiography with HeartModelA.I. (HM), with different border detection settings (HM 70–30, HM 80–40 and HM 90–50); and cardiac magnetic resonance (CMR). Solid horizontal line indicates median values; hatched box, quartiles; and vertical line, highest and lowest values. Mean values are indicated above each box.

(752 Ko)
 Supplementary Figure 2 
Supplementary Figure 2. 

Comparison of different default settings for the automated border detection of the HeartModelA.I. (HM 90–50 and HM 70–30) with the “standard” 80-40 setting for: (A) left ventricular end-diastolic volume (EDV); (B) left ventricular end-systolic volume (ESV); and (C) left ventricular ejection fraction (EF), using Bland-Altman analyses.

(1.51 Mo)
 Supplementary Figure 3 
Supplementary Figure 3. 

Comparison of different default settings for the automated border detection of the HeartModelA.I. (HM 90–50, HM 80–40 and HM 70–30) with cardiac magnetic resonance (CMR) for: (A) left ventricular end-diastolic volume (EDV); (B) left ventricular end-systolic volume (ESV); and (C) left ventricular ejection fraction (EF), using Bland-Altman analyses.

EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline