S'abonner

Randomized controlled pilot study of the preoperative use of brimonidine 0.33% topical gel for hemostasis in Mohs micrographic surgery - 23/11/17

Doi : 10.1016/j.jaad.2017.08.022 
Edward Chen, BA a, b, Raj Ajay Patel, MD b, Young Jin Kwak, MD b, Conway C. Huang, MD b,
a University of Alabama School of Medicine, Birmingham, Alabama 
b Department of Dermatology, University of Alabama at Birmingham, Birmingham, Alabama 

Reprint requests: Conway C. Huang, MD, Department of Dermatology, University of Alabama at Birmingham, 1720 2nd Ave S, EFH 414, Birmingham, AL 35294-0009.Department of DermatologyUniversity of Alabama at Birmingham1720 2nd Ave S, EFH 414BirminghamAL35294-0009

Abstract

Background

Brimonidine topical gel may be useful in cutaneous surgical procedures because of its vasoconstricting properties.

Objective

Assess the hemostatic effect of topically applied brimonidine in patients being treated with anticoagulants and undergoing Mohs micrographic surgery (MMS).

Methods

Subjects undergoing MMS were randomly assigned to the control (n = 10) or study arm (n = 14). Controls received standard-of-care MMS, whereas the study arm received the same and preoperative application of brimonidine. Evaluations included rate of blood flow, percentage of wound bed surface area needing electrocautery, and changes in skin colorimeter readings.

Results

The treatment arm had 68% less blood loss over 30 seconds versus the control arm (P < .05). No patient in the brimonidine arm had more than 50% of the wound bed cauterized versus 80% in the controls. Erythema in the treatment arm was decreased by 3.89 times (P < .01) versus in the control arm.

Limitations

Limitations were small sample size; sites limited to the face; the fact that measurement of bleeding did not account for anesthetic mixed with blood; visual estimation of percentage of wound surface area requiring cauterization; and no measurement of volume of anesthesia, wound depth, or postoperative complications.

Conclusion

Preoperative application of brimonidine 0.33% gel may help decrease blood loss and the need for electrocautery during MMS for patients taking anticoagulants.

Le texte complet de cet article est disponible en PDF.

Key Words : anticoagulants, brimonidine, electrocautery, hemostasis, Mohs micrographic surgery, nonmelanoma skin cancer

Abbreviations used : BCC, MMS, SCC


Plan


 Funding sources: None.
 Conflicts of interest: None declared.


© 2017  American Academy of Dermatology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 77 - N° 6

P. 1114-1118 - décembre 2017 Retour au numéro
Article précédent Article précédent
  • Gefitinib for patients with incurable cutaneous squamous cell carcinoma: A single-arm phase II clinical trial
  • William N. William, Lei Feng, Renata Ferrarotto, Lawrence Ginsberg, Merrill Kies, Scott Lippman, Bonnie Glisson, Edward S. Kim
| Article suivant Article suivant
  • Fontana-Masson stain in fungal infections
  • Kelly Leigh West, Alan D. Proia, Puja Kumari Puri

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.