Article

7 Iconography
Access to the text (HTML) Access to the text (HTML)
PDF @@113110@@
Service d'aide à la décision clinique
Advertising


Access to the full text of this article requires a subscription.
  • If you are a subscriber, please sign in 'My Account' at the top right of the screen.

  • If you want to subscribe to this journal, see our rates



Neurochirurgie
Vol 49, N° 2-3  - mai 2003
pp. 215-225
Doi : NCHIR-05-2003-49-2-3C2-0028-3770-101019-ART10
Analyse de la marche spastique
Contribution du laboratoire d'analyse du mouvement
 

O. RÉMY-NÉRIS [1], S. BOUILLAND [1], B. BUSSEL [2]
[1]  Groupe Hopale, Laboratoire d'Analyse du Mouvement, Berck-sur-Mer.
[2]  Service de Médecine Physique et Réadaptation, Hôpital Raymond-Poincaré, Garches.

Tirés à part : O. Rémy-Néris [2]

[3]  Groupe hopale, Centre Calvé, 62600 Berck-sur-Mer.

Abstract
Spastic gait analysis. Contribution of the motion lab

Étienne-Jules Marey introduced gait motion analysis at the end of the xixth century. It was rapidly adopted by clinicians and Charcot used it at the beginning of the xxth century in La Salpêtrière. Motion analysis was widely used after the first optoelectronic system was built by Furné in 1968. The optoelectronic system calculates the orientation of each body segment in the space after the determination of the space co-ordinates of cutaneous markers placed over them. It is particularly useful for spastic gait. Many disturbances of kinematics and kinetics have been described during spastic gait. They are the consequences of spasticity and other motor and sensory deficits of central nervous system lesions. Motion analysis must be coupled with electromyographic recording of spastic muscles activity which, with kinetic analysis, enables distinguishing the mechanisms underlying gait disturbances. Motion analysis provides clinicians with an indispensable tool for understanding spasticity and evaluating therapeutic efficacy.

Keywords: spasticity , hypertonia , gait , motion analysis






© 2003 Elsevier Masson SAS. Tous droits réservés.
EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline
You can move this window by clicking on the headline