S'abonner

Adjustable stemmed shoulder hemiarthroplasty: Ten-year results of a prospective multicentre study - 08/03/19

Doi : 10.1016/j.otsr.2018.09.017 
Ulrich Irlenbusch a, , Peter Zenz b, Georges Blatter c, Alexander Berth d
a Sportklinik Erfurt, Am Urbicher Kreuz 7, 99099 Erfurt, Germany 
b Otto Wagner Hospital, 1140 Vienna, Austria 
c Rosenberg Clinic, Orthopaedic Surgery, 9410 Heiden, Switzerland 
d Department of Orthropaedic Surgery, Otto von Guericke University, 39106 Magdeburg, Germany 

Corresponding author. Sportklinik Erfurt, Am Urbicher Kreuz 7, 99099 Erfurt, Germany.Sportklinik Erfurt, Am Urbicher Kreuz 7Erfurt99099Germany
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 08 March 2019
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

Adjustable shoulder hemiarthroplasty (HA) allows the complex anatomy of the proximal humerus, including its centre of rotation, to be restored. However, whether better anatomical adaptation improves clinical outcomes and long-term survival remains unclear. Therefore long-term clinical and radiographic results of an eccentric adjustable hemiprosthesis were examined, focusing on the longevity and fixation of the humeral stem.

Hypothesis

Adjustable shoulder HA enhances long-term functional outcomes and reduces complications.

Materials and methods

In this prospective multicentre study, 120 HAs were performed using a stemmed hemiprosthesis on 115 patients. The clinical and radiologic outcomes were measured at 3, 6, 12, and 24 months, and thereafter at 4, 7, and 10 years with a median follow-up period of 7.7 years (92.3 months, range 2.6–148.5 months). Revision-free survival rates were calculated up to 10 years postoperatively.

Results

The mean Constant-Murley score increased over the first 24 months from 26.2±9.0 to 61.0±17.3 points, then levelled off until the final follow-up. Patients with humeral head necrosis had the best clinical outcomes, while patients with fracture sequelae and rheumatoid arthritis had the worst. Although radiolucent lines were more frequent after cemented fixation, lines of>2mm only occurred after uncemented fixation. Finally, five cases required secondary glenoid implantation, and survival free from stem revision was 99.0% (95% confidence interval [CI], 92.8%–99.9%) at 4 years, 97.6 (95% CI, 90.6%–99.4%) at 7 years, and 92.2% (95% CI, 81.9%–96.8%) at 10 years.

Discussion

The study showed that adjustable shoulder HA is a safe and effective treatment option for various degenerative disorders of the shoulder joint. Functional scores first increased, then levelled off after 24 months. Moreover, revision-free survival compared well with previously reported values. Observed stable long-term results confirm that adjustable shoulder HA has beneficial clinical outcomes and a low complication rate.

Le texte complet de cet article est disponible en PDF.

Keywords : Shoulder prosthesis, Hemiarthroplasty, Adjustable stem, Shoulder arthroplasty, Shoulder joint, Joint diseases


Plan


© 2018  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.