Mismatch between rod bending and actual post-operative lordosis in lumbar arthrodesis with poly axial screws - 29/03/19

Doi : 10.1016/j.otsr.2019.03.003 
Abdollah Yassine Moufid a, , Thibault Cloche b, Soufiane Ghailane c, Amine Ounajim d, Tanguy Vendeuvre a, Olivier Gille c
a Université de Poitiers, Poitiers university hospital, centre hospitalo-universitaire de Poitiers Unité rachis, 1, rue de la Milétrie, 86021 Poitiers, France 
b Polyclinique Bordeaux Nord Aquitaine, 15–35, rue Claude-Boucher, 33300 Bordeaux, France 
c Université de Bordeaux, Bordeaux university hospital, centre hospitalo-universitaire de Bordeaux, Spine Unit 1, place Amélie-Raba Léon, 33076 Bordeaux, France 
d Centre hospitalo-universitaire de Poitiers Prismatics, 1, rue de la Milétrie, 86021 Poitiers, France 

Corresponding author at: Université de Poitiers, Poitiers University Hospital, orthopedic Department, CHU de Poitiers, 1, rue de la Milétrie, 86021 Poitiers, France.Université de Poitiers, Poitiers University Hospital, orthopedic Department, CHU de Poitiers1, rue de la MilétriePoitiers86021France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 29 March 2019
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

The question of rod bending is essential during posterior lumbar fusion. The role of posterior instrumentation during spinal surgery remains to be defined. Despite an appropriate bending, a mismatch between rod lordosis and lumbar lordosis can occur. There is no study on the link between rod bending and lordosis. The purpose of this study was to evaluate parameters that explain the mismatch between lumbar lordosis and rod bending in lumbar surgery using polyaxial screws.

Hypothesis

Radiological parameters explain the mismatch between the rod and the lordosis.

Methods

This study was monocentric, retrospective, descriptive and analytic. All patients with posterior L3L5 fusion in an university-affiliated hospital in 2017 were included. Patients with past surgical history of anterior fusion on the levels L3L5, Coronal malalignment with a Cobb angle superior to 5°, the use of dynamic fixation systems were excluded. We measured on immediate post-operative standing profile x-ray: pelvic incidency, lumbar lordosis, lordosis of the instrumented segment, the distance between posterior wall and rod (EcarT) which reflect how homogeneously the screws are put in depth, the angle between screw and rod (thetaMA), the angle between screw and superior endplate (lambdaMA), the rod lordosis. Univariate and multivariate analysis were conducted to see if there was a link between all those parameters and the mismatch: vertebral lordosis-rod lordosis.

Results

A total of 74 patients were included, mean age was 67. Eighteen were 360° fusion and 56 were postero-lateral fusions. There was no statistical association between demographic data, pelvic parameters, use of interbody devices and the mismatch. There was a statistical association between thetaMA, lambdaMA, EcarT and the mismatch (P<0,0001). A multivariate linear regression model was developed to create a new index: Mismatch analysis index.

Conclusion

Our study is the first on the link between rod bending and lumbar lordosis. Three radiologic factors are involved in not obtaining the planned lordosis in short lumbar fusion with polyaxial screws. Two factors depend on the way the surgeon positions screw parallel to the superior vertebral endplate(lambdaMA), and with a homogeneous depth (EcarT). And the last factor: ThetaMA is depending on the surgical technique (compression on screws, osteotomies, monoaxial screws, use of interbody devices).

Level of evidence

IV.

Le texte complet de cet article est disponible en PDF.

Keywords : Rod bending/contouring, Mismatch, Lordosis, Poly axial screw, Mono axial screw


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.