S'abonner

Description of the potential of an arthrometer for standard and reduced radiographs suitable to measurement of angles and segments of hip, knee, foot and joint space widths - 01/01/02

Michel  Lequesne 1 * ,  Gérard  Morvan 2 *Correspondence and reprints: 33 rue Guilleminot 75014 Paris, France

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 11
Iconographies 15
Vidéos 0
Autres 0

Résumé

Background. Primary osteoarthritis is usually selected in either epidemiological or therapeutic studies. This implies exclusions. Among cases of secondary osteoarthritis considered for either stratification or exclusion - or for prognosis and treatment in daily practice - are those due to architectural defects. Parameters of the latter should be measured to ascertain diagnosis. At present, measurements have to be performed either on digitized reduced films or standard radiographs. Objective. To finalize an instrument capable of measuring the main angles and segments characteristic of the main dysmorphisms of the hip, knee and foot on different sizes of films. Methods. An arthrometer drawn on transparent material to be placed on radiographs was designed, involving several appropriate protractors and millimetric scales; it was tested on 60 hip, 35 knee and 17 foot radiographs with various architectural defects. Angles and segments most often used according to literature were measured. Reduction rates of films were various, reflecting the range of radiograph sizes currently used in everyday practice. Results. Measurements were easily performed on radiographs from standard (100%) up to 50% of reduction rate. So the arthrometer allows the recognition, especially in moderate, not obvious forms, of the following developmental or acquired dysmorphisms: hip congenital dysplasia and subluxation, including coxa valga and neck excess of anteversion; acetabular protrusion and coxa vara; tilt deformity; knee: patellar height abnormalities, patellar maltracking, trochlear depth insufficiency; foot: pes cavus, flat foot. Angle and segment ratios do not change in reduced film, whereas segments (absolute lengths) obviously should be converted according to the reduction rate for retrieving the classical values established for decades. Conclusion. The arthrometer allows us to measure the relevant parameters of various dysmorphisms without drawing lines over the films themselves. It is suitable to reduced as well to standard radiographs. However, only the instrument and its ability to be used in various films sizes are here presented. Study of reproducibility of measurements - especially concerning the joint space width - remain to be performed.

Mots clés  : arthrometer ; dysmorphisms ; foot ; hip ; joint space width ; knee ; radiographic measurements.

Plan



© 2002  Éditions scientifiques et médicales Elsevier SAS. Tous droits réservés.

Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 69 - N° 3

P. 282-292 - mai 2002 Retour au numéro
Article précédent Article précédent
  • Use of disease-modifying antirheumatic drugs in patients with psoriatic arthritis
  • Laurent Marguerie, René-Marc Flipo, Bruno Grardel, Didier Beaurain, Bernard Duquesnoy, Bernard Delcambre
| Article suivant Article suivant
  • Muscle performance in patients with fibromyalgia
  • Didier Maquet, Jean-Louis Croisier, Cindy Renard, Jean-Michel Crielaard

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.