Automated function imaging: a new operator-independent strain method for assessing left ventricular function - 14/05/08

Doi : ACVD-03-2008-101-3-1875-2136-101019-200803515 

H. Belghitia,

S. Brette,

S. Lafitte,

P. Reant,

F. Picard,

K. Serri,

M. Lafitte,

M. Courregelongue,

P. Dos Santos,

H. Douard,

R. Roudaut,

A. DeMaria

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Justification. — L’imagerie de Speckle est une nouvelle technique basée sur une échelle de gris, en imagerie 2D, avec acquisition permettant le calcul de la déformation segmentaire. Afin de faciliter l’application clinique, le coutourage et la technique de Speckle ont été intégrés dans la plupart des appareils récents d’échocardiographie, pour une évaluation rapide et automatique de la fonction ventriculaire gauche (Automated function Imaging, AFI).

Objectif. — Évaluer la stabilité, le temps d’évaluation, la pertinence et la reproductibilité d’une méthode globale de détermination du strain longitudinal (GLS) à partir de la technique AFI, dans la détermination de la fonction ventriculaire gauche, en comparaison à une référence échographique et angiographique, quelle que soit l’expérience de l’opérateur.

Méthodes. — L’échographie a été réalisée chez 65 patients, planifiés pour une exploration hémodynamique cardiaque en utilisant un système Vivid 7. Le groupe de patients a été divisé en 3, en fonction de la valeur de la fraction d’éjection ventriculaire gauche (> 55 %, entre 35 et 55 %, et < 35 %). La qualité d’image, les paramètres de fonction globale du ventricule gauche (FEVG), du flux aortique (dp/dt) et de contraction segmentaire ont été analysés par un observateur expérimenté et un débutant. Le strain global longitudinal a été obtenu en incidences apicales 2, 3 et 4 cavités. Ce paramètre a été comparé à la valeur de la fraction d’éjection échographique et angiographique, ainsi qu’aux autres paramètres échographiques.

Résultats. – Le strain longitudinal global a été obtenu chez 97 % des patients. Le temps de calcul moyen, incluant le calcul de corrélation pour la détection endocardique, a été inférieur à 60 secondes. Le strain longitudinal global était significativement différent dans les trois groupes, respectivement -18,1 ± 2,5 %, -11,5 ± 2,1 % et -6,0 ± 1,2 % (p < 0,01). Des corrélations significatives ont été observées entre le strain longitudinal global et la fonction ventriculaire gauche (r variant entre 0,68 et 0,87), avec un haut niveau de reproductibilité. Il n’y avait pas de différence entre l’observateur expérimenté et débutant (inexpérimenté).

Conclusion — La technique AFI est donc applicable en clinique et pourrait constituer un outil performant pour l’évaluation de la fonction ventriculaire gauche, lié à un temps d’acquisition court, à une bonne faisabilité, et à une performance diagnostique, quelle que soit l’expérience de l’observateur.

Background. — Speckle tracking is a new technique based on pure 2D grayscale ultrasound acquisition allowing calculation of segmental strains. To facilitate clinical application, speckle tracking has been integrated into the most recent echocardiographic systems for quick, automated evaluation of left ventricular function (Automated Function Imaging, AFI).

Objective. — To evaluate the feasibility, calculation time, accuracy and reproducibility of global longitudinal strain (GLS) from AFI in determining LV function in comparison to reference echocardiographic and angiographic methods—whatever the operator’s experience.

Methods. — Echocardiography was performed in 65 patients scheduled for cardiac catheterization using a Vivid 7 system. They were divided into 3 groups according to EF (>55%, 35≤EF≤55%, <35%). Image quality, global LV function parameters (ejection fraction, aortic flow, dp/dt) and segmental contraction were analyzed by one experienced operator and one beginner. GLS was obtained from apical 2, 3 and 4 chamber views. GLS was compared to both echocardiographic and angiographic EF, as well as to other echocardiographic parameters.

Results. — GLS was obtained successfully in 97% of patients. Mean calculation time including correction of endocardial detection was less than 60 seconds. GLS was significantly different between the 3 groups, respectively -18.1±2.5 %, -11.5±2.1% and -6.0±1.2% (p<0.01). Strong correlations were observed between GLS and LV function (r from 0.68 to 0.87) with a high level of reproducibility. No difference was observed between experienced and inexperienced operators.

Conclusion. — AFI is clinically applicable and an effective means of assessing LV function due to its short acquisition time, feasibility and accuracy, whatever the experience of the operator.


Mots clés : Imagerie Speckle , Fonction myocardique régionale , Déformation , AFI

Keywords: Speckle tracking , Regional left ventricular function , Strain , AFI


Plan



© 2008 Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 3

P. 163-169 - mars 2008 Retour au numéro

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.