Gynécologie Obstétrique & Fertilité
Volume 31, n° 1
pages 29-42 (janvier 2003)
Doi : 10.1016/S1297-9589(02)00013-9
Dégradation in utero des DIU au cuivre en fonction du temps. Le phénomène de corrosion métallique. Étude au microscope électronique à balayage
Degradation of copper IUDs in utero. The process of metallic corrosion. A scanning electron microscope study

J.  Berthou a ,  F.C.  Chrétien b * ,  P.A.  Driguez c
aLaboratoire de minéralogie-cristallographie, université Pierre-et-Marie-Curie, 4, place Jussieu, 75230 Paris cedex 5, France 
bLaboratoire de physiopathologie de l'implantation et du développement, université Pierre-et-Marie-Curie, 12, rue Cuvier, 75230 Paris cedex 5, France 
cLaboratoire de physiopathologie de l'implantation et du développement, université Pierre-et-Marie-Curie, 7, rue Chernoviz, 75016 Paris, France 

*Auteur correspondant.
@@#100979@@

Objectif. - La présente étude a été réalisée dans le but de mieux comprendre le phénomène de corrosion du métal armant les DIU au cuivre sous l'influence des sécrétions utérines, d'en préciser les étapes et la localisation sur le DIU et de mieux cerner l'influence sur le phénomène d'éventuelles concrétions calcaires recouvrant les surfaces métalliques.

Matériel et méthodes. - Un total de 461 stérilets au cuivre de quatre modèles courants a fait l'objet d'un choix préalable à la loupe binoculaire et les spécimens considérés comme les plus spécifiques ont été étudiés au microscope électronique à balayage. Une analyse statistique a été appliquée aux données obtenues.

Résultats. - L'étude du processus de corrosion du cuivre métallique en fonction du temps a permis de montrer qu'il affecte essentiellement la partie basse du DIU sans variations significatives entre les modèles. Il a en outre été possible de préciser les étapes du processus de corrosion et d'en décrire les aspects les plus caractéristiques.

Discussion et conclusions. - La corrosion du cuivre d'un DIU in utero est un phénomène normal qui se développe préférentiellement dans la partie basse du stérilet et peut entraîner la disparition totale du métal. L'initiation du processus comme son évolution dans le temps montrent une grande variation interindividuelle. Elle peut être contrariée, au moins en cas de calcification drastique et rapide par d'épais dépôts de vatérite isolant précocement la partie basse du dispositif.

Mots clés  : DIU ; Cuivre ; Corrosion ; Microscope électronique à balayage.

Abstract

Objective. - The present investigation was carried out in order to study the process of metallic corrosion of copper IUD's in utero, to precise its dynamics and location along the IUD and to appraise the influence of eventual calcareous deposition.

Material and methods. - A total of 461 copper IUDs representing four standard models were screened by means of optical microscopy. Especially typical samples were studied at higher magnifications under the scanning electron microscope. The obtained data were considered in terms of statistics.

Results. - It was possible to demonstrate a preferential corrosive activity in the lower part of the IUD without significant variations between the models. It was also possible to precise the steps of the process, to describe its most characteristic aspects and to study the eventual effect of severe calcareous deposition on corroded copper.

Discussion and conclusions. - Intrauterine copper corrosion is a normal process which occurs preferentially in the cervical portion of an IUD and can lead to the total metal loss. Both its initiation and evolution are submitted to strong individual variations. Thick and compact vaterite deposits may thwart copper erosion in case of drastic and rapid deposition.

Mots clés  : IUD ; Copper ; Corrosion ; Scanning electron microscope.




© 2003  Éditions scientifiques et médicales Elsevier SAS. All Rights Reserved.

EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline