Archives of cardiovascular diseases
Volume 102, n° 10
pages 711-720 (octobre 2009)
Doi : 10.1016/j.acvd.2009.06.005
Received : 2 July 2008 ;  accepted : 18 June 2009
Sleep apnoea in patients with heart failure: Part II: Therapy
Apnée du sommeil et insuffisance cardiaque : partie II : thérapeutique
 

Philippe Bordier
Hôpital cardiologique du Haut-Lévêque, avenue de Magellan, 33604 Pessac cedex, France 

Fax: +33 5 56 04 38 49.
Summary

Nasal continuous positive airway pressure (CPAP) is generally recommended for the treatment of obstructive sleep apnoea. CPAP lowers the cardiovascular morbidity and mortality associated with severe obstructive sleep apnoea. At least 50% of patients presenting with chronic heart failure (HF) have sleep apnoea; a subset of these patients may have obstructive sleep apnoea and may derive a survival benefit from CPAP. However, this population is also prone to developing central sleep apnoea, Cheyne-Stokes respiration or both (CSA/CSR), for which CPAP lowers the apnoea-hypopnoea index only partially and for which the overall effect of CPAP on survival remains to be determined, particularly as it has been observed to increase the mortality rate in subsets of patients. Other treatments may prove effective in patients with chronic HF and CSA/CSR, although none, thus far, has been found to confer a survival benefit. New ventilatory modes include bi-level positive airway pressure and automated adaptive servoventilation, the latter being most effective against CSA/CSR. Measures that can alleviate CSA/CSR indirectly include beta-adrenergic blockers and renin-angiotensin-aldosterone system inhibitors, nocturnal supplemental oxygen and cardiac resynchronization therapy (CRT). The effects of theophylline, acetazolamide and nocturnal CO2 have also been studied. The second part of this review describes the applications and effects of therapies that are available for sleep apnoea in patients with chronic HF.

The full text of this article is available in PDF format.
Résumé

La ventilation en pression positive continue (VPPC) par masque faciale est généralement recommandée pour traiter l’apnée du sommeil obstructive (ASO). Ce mode de ventilation réduit la morbidité et la mortalité cardiovasculaires associées aux ASO sévères. Chez les sujets souffrant d’insuffisance cardiaque chronique, plus de la moitié ont une apnée du sommeil. Ceux atteints d’ASO semblent avoir un pronostic vital amélioré par la VPPC. Cependant, les patients insuffisants cardiaques ont souvent une apnée du sommeil d’origine centrale et/ou une respiration de Cheyne-Stokes (ASC/RCS). Chez eux, la VPPC améliore l’ASC/RCS de façon inconstante et l’impact sur l’espérance de vie reste à préciser, d’autant plus que la VPPC a pu être responsable d’une surmortalité chez certains de ces patients. D’autres traitements s’avèrent efficaces contre l’ASC/RCS chez l’insuffisant cardiaque, mais à ce jour, aucun n’a montré qu’il apportait un bénéfice en termes de survie. Il s’agit d’appareils de ventilation pouvant délivrer deux niveaux de pression positive ou bien de servoventilateurs ayant des capacités d’adaptation automatique des pressions inspiratoires et expiratoires particulièrement efficaces contre l’ASC/RCS. D’autres thérapeutiques peuvent améliorer indirectement l’ASC/RCS, comme les β-bloquants, les inhibiteurs du système rénine-angiotensine-aldostérone, l’oxygénothérapie nocturne et la resynchronisation du myocarde par stimulation cardiaque. Les effets de la théophylline, de l’acétazolamide et de l’enrichissement de l’air inspiré en dioxide de carbone pendant le sommeil ont également été étudiés. La seconde partie de cette revue décrit les applications et les effets des thérapeutiques disponibles contre l’apnée du sommeil chez les patients atteints d’insuffisance cardiaque chronique.

The full text of this article is available in PDF format.

Keywords : Sleep apnoea, Heart failure

Mots clés : Apnée du sommeil, Insuffisance cardiaque


Abbreviations

AHI : apnoea-hypopnoea index
HF : heart failure
CPAP : continuous positive airway pressure
CRT : cardiac resynchronization therapy
CSA : central sleep apnoea
CSR : Cheyne-Stokes respiration
LVEF : left ventricular ejection fraction
OSA : obstructive sleep apnoea
PaCO2  : partial pressure of carbon dioxide in the arterial blood
PCO2  : partial pressure of carbon dioxide

Introduction

Nasal CPAP is generally recommended for the treatment of OSA, including for patients presenting with cardiovascular disorders [1]. CPAP lowers the cardiovascular morbidity and mortality associated with severe OSA [2]. At least half of the patients who present with chronic HF have sleep apnoea; a subset of these patients may have OSA, i.e., greater or equal 50% of abnormal respiratory events during sleep are of obstructive pattern [3, 4], and may derive a survival benefit from CPAP [5, 6, 7, 8]. However, this population is also prone to developing CSA, CSR or both (CSA/CSR) [3, 4], for which CPAP lowers the apnoea-hypopnoea index (AHI; defined as the number of apnoeas and hypopnoeas per hour of sleep) only partially. The overall effect of CPAP on survival remains to be determined, particularly as it has been observed to increase the mortality rate in subsets of patients with chronic HF and CSA/CSR [9, 10]. Other treatments may prove effective in patients with chronic HF and CSA/CSR, although none, thus far, has been found to confer a survival benefit. New ventilatory modes include bi-level positive airway pressure and automated adaptive servoventilation. Measures that can alleviate CSA/CSR indirectly include beta-adrenergic blockers and renin-angiotensin-aldosterone system inhibitors, nocturnal supplemental oxygen and CRT. The effects of theophylline, acetazolamide and nocturnal CO2 have also been studied. The second part of this review describes the therapies currently available for sleep apnoea in patients presenting with chronic HF. The impact of these treatments on functional status, cardiac performance, morbidity and mortality is still being evaluated.

Therapies with direct effects on abnormal sleep-related respiratory events

Alleviation of sleep apnoea by ventilation systems may improve cardiac performance.

Continuous and bi-level positive airway pressure

CPAP is the treatment recommended for OSA in patients presenting with chronic HF [5, 6, 7, 8]. The continuous insufflation of air under pressure through a nasal or facial mask opposes the flaccidity and collapsibility of the upper airways during inspiration, maintaining the patency of the pharyngeal duct. In these patients, CPAP may improve cardiac function. In a randomized study of 24 patients, 1 month of CPAP increased the mean LVEF from 25.0 to 33.8% [5]. These observations, however, were not confirmed by Smith et al., who noted that OSA was alleviated in the absence of changes in indices of cardiac function or functional status [7]. CPAP has been found to lower morbidity and mortality in patients with chronic HF and OSA, with no serious adverse cardiovascular effects [6, 8]. However, although data are scarce, the treatment of OSA with CPAP appears to aggravate myocardial dysfunction in patients presenting with chronic HF and atrial fibrillation [1]. Measurements made during cardiac catheterization in one study showed a fall in cardiac index in six patients with atrial fibrillation, compared with in five patients in sinus rhythm, when up to 10cm H2 O of CPAP was applied for 30minutes [11]. However, this short-term study was performed in only a few patients presenting with chronic HF, in the absence of sleep apnoea and while they were awake. With non-permanent atrial fibrillation, the risk of myocardial intolerance of CPAP seems lower. One study reported fewer recurrences of atrial fibrillation after cardioversion in patients with OSA treated with CPAP, compared with in patients with untreated OSA [12]. Patients with chronic HF were not excluded and greater than 50% were in New York Heart Association functional class II, III or IV, with a mean LVEF of 52±13%. After 12 months of treatment with CPAP, the only significant difference found between patients with and without recurrences of atrial fibrillation was correctly applied treatment in the latter group. While no adverse effect of CPAP has been reported, lack of compliance with treatment may be a challenging issue. Furthermore, in OSA, the severity of nocturnal O2 desaturation seems to be an independent risk factor for the development of atrial fibrillation [13]. The restoration of proper O2 saturation might therefore explain the lower rate of recurrence of atrial fibrillation associated with CPAP treatment.

Although CPAP acts via anatomical changes at the pharyngeal level, it may also correct CSA/CSR [9, 10]. In chronic HF due to systolic or diastolic dysfunction, the left ventricular end-diastolic pressure is usually elevated. The insufflation of air by the CPAP device maintains a constantly positive intrathoracic pressure, narrowing the pressure difference between the left intraventricular and intrathoracic pressures [14, 15, 16]. The resulting decrease in left ventricular end-diastolic pressure facilitates the filling of the failing left ventricle and increases its stroke volume. In addition, by raising the intrathoracic pressure, CPAP decreases the venous return to the right heart and alleviates pulmonary interstitial and myocardial congestion. The decrease in left ventricular preload may also contribute to an increase in cardiac output. The improvement in cardiac performance in turn restores the central respiratory drive, which alleviates CSA/CSR [17]. Fewer apnoeas are associated with a decrease in sympathetic activity, fewer surges in heart rate and blood pressure, less peripheral vasoconstriction and a decrease in left ventricular afterload [16]. In addition, the decrease in apnoeic-hypopnoeic events produced by CPAP limits the number of dips in blood O2 saturation, which may increase the cardiac output by relieving myocardial ischaemia.

In clinical studies, CPAP alleviated the manifestations of chronic HF, improved the cardiac loading conditions, increased LVEF and mitigated the severity of CSA/CSR [9, 10, 18], although these changes have not been observed systematically [9, 10, 19]. In contrast to OSA, the effects of CPAP on CSA/CSR in patients presenting with chronic HF are less prominent, in the order of a 40 to 60% decrease in apnoeic events [10, 20, 21].

Sin et al. reported a higher survival rate among patients with chronic HF and CSA/CSR treated with CPAP than among untreated patients [18]. However, in a similar patient population, the randomized CANPAP study found an early increase in mortality in the group of patients assigned to CPAP compared with untreated controls, perhaps because of a decreased cardiac output due to the effects of CPAP on left ventricular preload and filling; at 2 years, however, the death and transplantation rates were similar in both study groups [10]. In both the control and the CPAP-treated groups, mortality was due predominantly to progressive chronic HF and sudden death. A more detailed post-hoc analysis of the CANPAP study found that patients in whom the AHI had decreased below 15 after 3 months of CPAP had a greater increase in LVEF and a higher cardiac transplantation-free survival rate than the control group [9]. In that subgroup, LVEF increased by an average of 3.6% within 3 months, from a mean baseline value of 25.6% – an increase significantly greater (p <0.001) than that observed in the group not treated with CPAP. In contrast, no significant difference was observed in LVEF and heart transplant-free survival, between the group of patients whose AHI had remained greater or equal to 15 after 3 months of CPAP and the control group. Therefore, when CPAP is prescribed for the management of CSA/CSR in patients with chronic HF, its effects on AHI need to be closely monitored during the first 3 months of treatment, and it should be discontinued if its effects are unapparent or weak.

Between 1998 and 2004, the death and cardiac transplantation rate in the combined CPAP and control groups of the CANPAP trial fell from 20 per 100 person-years to four per 100 person-years (p =0.003) [10]. This profound decrease in the rate of the primary study endpoint, observed in both groups, was independent of CPAP, and attributable to changes in medications prescribed during the study. In particular, the proportion of patients treated with beta-adrenergic blockers and spironolactone increased from 58 to 86% (p <0.001) and from 14 to 41% (p =0.001), respectively, while the prescription of digoxin decreased from 72 to 36% (p =0.002). The role played by pharmaceuticals in CSA/CSR will be further discussed later.

Because the air is simply insufflated continuously, CPAP should a priori be ineffective in the absence of spontaneous respiratory efforts, as in CSA/CSR, although this may not be the case, as discussed earlier. Bi-level ventilation systems have been tested in CSA/CSR, as they can ventilate a patient in the absence of breathing efforts, corresponding to non-invasive assisted ventilation with a nasal or facial mask as well as CPAP [22, 23]. In addition, if the pressure applied by CPAP during expiration is identical to that applied during inspiration, bi-level ventilation allows the setting of a low positive expiratory pressure for patients who are uncomfortable when exhaling against a high positive pressure. The spontaneous/timed mode is usually selected [22, 23]. Bi-level ventilation in the spontaneous mode can be effective in OSA and is best implemented with a backup rate (timed mode) for CSA/CSR. For example, during spontaneous breathing, the patient is ventilated in an assisted mode at a fixed inspired pressure, which is two to three times lower and fixed during expiration. Should CSA/CSR occur, the ventilator switches, in a few seconds, to controlled delivery of the same pressures as during assisted ventilation and with a breathing rate preset at 12 to 15 breaths/minute. Upon the return of spontaneous breathing, assisted ventilation resumes. Bi-level ventilation has been found to be as effective as CPAP in alleviating CSA/CSR in patients with chronic HF [21, 22, 23, 24]. In a study of 16 patients, a 14-day delivery of CPAP, set at 8.5 mbar, was compared with the delivery of bi-level ventilation, set at 8.5/3 mbar, each for 14 days [23]. AHI was similarly and significantly lowered, from 26.7±10.7 at baseline to 7.7±5.6 and 6.5±6.6 by CPAP and bi-level ventilation, respectively. Another study reported an increase in LVEF from 36.3±2.9% to 46.0±4.0% (p =0.02) in seven patients with chronic HF and CSA/CSR treated with 3 months of bi-level ventilation, compared with a non-significant decrease from 34.1±3.7% to 32.7±3.2% in seven control patients who remained treated with medications only [22]. In that study, the final mean positive inspiratory/expiratory settings of bi-level ventilation were 13.6±3.6/7.9±3.0cm H2 O and the respiratory rate was 15.7±0.5 breaths/minute. As in the case of CPAP, the decrease in central apnoea burden by bi-level ventilation in this population of patients with chronic HF was attributed mostly to the therapeutic effects of the increased intrathoracic pressures on the failing myocardium.

The highest compliance with and efficacy of the system is achieved by titrating the pressures of CPAP or bi-level ventilation, which can be performed manually, adjusting the air pressures to lower the number of apnoeas-hypopnoeas to a maximum tolerated by the patient [21]. These adjustments in ventilation settings can be made at the bedside by a sleep technician, in a single session or over several nocturnal sessions, during pulse-finger oxymetric or polygraphic/polysomnographic monitoring. In the absence of a sleep technician, these preliminary recordings can be reviewed the following day, and the pressure re-adjusted for the next night. In case of OSA, the device can be titrated automatically by algorithms based on an automated analysis of the upper airway resistance to airflow. Autotitrating is theoretically contraindicated in patients with chronic HF, who might not tolerate the pressure levels applied automatically, particularly when at home and unattended [1]. In practice, however, no adverse event was observed in a recent study of patients with chronic HF and OSA, in whom CPAP was autotitrated [7].

Automated adaptive servoventilation

Nocturnal automated adaptive servoventilation with a facial mask is available for the treatment of CSA/CSR, and mixed and complex sleep apnoea. Its advantages are being studied, in particular in patients with chronic HF [19, 20, 21, 24, 25, 26]. With a 91% decrease in central apnoeas in a single night, servoventilators have been found to be more effective than CPAP, bi-level ventilation and nocturnal O2 supplementation, for the management of CSA/CSR in patients with chronic HF [21]. Other small studies in patients with chronic HF have found unequivocally positive effects of servoventilators on CSA/CSR [20, 24, 25], mixed sleep apnoea [20] and complex sleep apnoea [20, 24] in acute settings. The efficacy of servoventilators in the management of CSA/CSR has been confirmed at 1 month [26] and 6 months [19].

The physical characteristics of servoventilators are similar to those of CPAP or bi-level ventilation apparatuses. However, they include their own specific algorithms of assisted-controlled inspiration and controlled positive expiratory pressure. The algorithms are based on continuous, cycle-by-cycle measurements of ventilation amplitude and airflow pressure. A volume of air is delivered automatically through the facial mask, at a pressure that compensates for the incomplete tidal volume amplitude. The system smoothes the CSR cycles, during which the ventilatory amplitude increases and decreases in phases separated by apnoea or hypopnoea. Therapeutic ventilation can begin with the default settings of the device manufacturer; for example, an end-expiratory pressure set at 5cm H2 O, sufficient to control any obstructive apnoea, and an inspiratory pressure support between 3 and 10cm H2 O. The support setting is the difference between end-inspiratory and end-expiratory pressures, with a minimum setting of 3cm H2 O and a maximum setting of 10cm H2 O. The default backup respiratory rate is 15 breaths/minute, above or below which the device tracks the patient’s spontaneous rate automatically [21, 26]. Populations of patients with chronic HF and CSA/CSR in whom servoventilators have been tested, presented with a large majority of central respiratory events, as opposed to obstructive or mixed respiratory events [21, 26].

Compared with the improvement in quality of life provided by CPAP in patients with common OSA, the effects of CPAP [10] or servoventilation [19, 24, 26] in patients presenting with chronic HF and CSA/CSR are more modest. This is probably due to the mild or absent sleep apnoea-induced symptoms reported by these patients [19]. Trials are in progress to examine the effects of servoventilation on the morbidity and mortality of patients with chronic HF and CSA/CSR. The impact of servoventilation on cardiac function has been examined in a single randomized study of 25 patients [19]. After 6 months of treatment, a 6% increase in LVEF was observed in seven patients assigned to servoventilation, as opposed to an approximately 3% decrease in six patients assigned to CPAP – a statistically significant difference. It is noteworthy that, in that randomized study, and in contrast to other studies in similar patient populations [9, 10], CPAP was not associated with an increase in LVEF at 6 months [19].

The long-term compliance with this cumbersome and constraining therapy remains to be determined. The sensation of suffocation associated with a facial mask is a major issue in patients with chronic HF, whose original chief complaint is discomfort due to dyspnoea. In studies of CPAP for OSA, patient compliance was limited mainly by the mask and by local discomfort and complications.

Therapies with indirect effects on abnormal sleep-related respiratory events

When these therapies improve cardiac performance, they may alleviate sleep apnoea.

Medications for chronic congestive heart failure

The prominent effects of beta-adrenergic blockers and spironolactone on the survival rate of patients enrolled in the CANPAP trial [10] were reminiscent of earlier observations in patients with chronic HF treated with beta-adrenergic blockers, angiotensin-converting enzyme inhibitors and spironolactone, in whom the positive effects on morbidity and mortality became apparent after 3 to 6 months of treatment. A positive effect of angiotensin-converting enzyme inhibitors on sleep apnoea has been reported [27], as well as the alleviation of CSA/CSR by beta-adrenergic blockers in patients with chronic HF [28]. A mean AHI of 14±11 was measured in 27 patients treated with carvedilol 5 to 10mg/day, vs 33±17 (p <0.0001) in 18 similar patients who did not receive a beta-adrenergic blocker. In another study, a decrease in mean AHI from 34±13 before, to 14±13 after 6 months of treatment with carvedilol 10mg twice daily (p =0.003), was measured in 16 patients [29]. In both studies, the decrease in AHI conferred by carvedilol was due to an alleviation of central apnoea. The alleviation of CSA/CSR conferred by these drugs might be viewed as a marker of their beneficial effects on the myocardium.

Nocturnal oxygen supplementation

A 45% decrease in the number of central apnoeic events has been reported in response to the acute delivery of O2 (2L/min) in patients with chronic HF who have sleep apnoea, with no effect on obstructive events [21]. As mentioned earlier, in that overnight study, the decreases in central apnoeas associated with CPAP, bi-level ventilation and servoventilation were 48, 76 and 91%, respectively. Another study in patients with chronic HF reported a 66% decrease in central AHI by CPAP, and a 70% decrease by O2 delivered at 2 L/min, each for 3 months [30]. In that study, increases in LVEF and exercise capacity were treatment benefits conferred by CPAP, which were not observed in patients treated with O2 . After 3 months of nocturnal O2 delivered at a rate of 3 L/min, AHI decreased from 21.0±10.8 to 10.0±11.6 (p <0.001) [31] – a 50% decrease in CSA/CSR burden consistent with previous observations, which was confirmed recently [32]. Furthermore, in these same studies, LVEF increased after 3 months of O2 supplementation from 34.7±10.4% to 38.2±13.6% (p =0.002) [31] and from 27±9% to 37±10% (p <0.01), respectively [32], and this was associated with a modest improvement in quality of life. This delayed effect of nocturnal O2 is attributed to a higher cardiac performance, associated with fewer abnormal respiratory events of central origin. The delivery of sufficient supplemental O2 [31] prevents or limits the dips in O2 during apnoea, hypopnoea (Figure 1) and secondary myocardial hypoxia. It also prevents the increase in myocardial O2 demand due to the bursts of central sympathetic activity occurring at the end of obstructive or central respiratory events [14, 15, 33]. Supplemental nocturnal O2 may also:

limit myocardial reperfusion injury due to the oxidative stress caused by periodic hypoxia-normoxia occurring during sleep apnoea [34];
increase partial pressure of carbon dioxide in the arterial blood (PaCO2 ), which decreases the severity of CSA/CSR, because hypocapnoea is a key factor in its development [17, 35];
mitigate hyperventilation and shorten the circulation time in patients with chronic HF, limiting the severity of hypocapnoea;
modulate the sensitivity of the chemoreceptors in the respiratory control system, interfering with the CO2 and O2 ventilatory drive;
promote the formation of oxyhaemoglobin instead of carboxyhaemoglobin, which increases PaCO2 ;
counteract hypoxia, which participates in the prolongation of apnoea when vagal afferent activity is stimulated by pulmonary congestion, resulting in inhibitory respiratory reflex.



Figure 1




Figure 1. 

Nocturnal O2 supplementation in chronic heart failure and sleep apnoea. Patient with an apnoea-hypopnoea index (AHI: number of apnoeas and hypopnoeas per hour of sleep)=39.2, O2 desaturation index (ODI: number of dips in O2 per hour of sleep)=35.4 and mean nocturnal blood oxygen saturation (SaO2 )=90.7% on baseline nocturnal ventilation polygraphy. 1A and 1B. Baseline recordings, showing mixed and obstructive apnoeas, respectively, with profound dips in O2 . 1C and 1D. Recordings during 3 L/min of nocturnal O2 supplementation; AHI=4.5, ODI=0.3 and mean nocturnal SaO2 =97.9%. 1C. Mixed residual apnoeas with very mild O2 desaturation. The heart rate is stable in this pacemaker recipient, with pacing at a backup rate of 70 bpm. Pacemaker programming was similar during baseline polygraphy. This indicates that the elimination of O2 desaturation during apnoeic events may suppress the autonomic nervous system instability. 1D. Prolonged, residual, abnormal respiratory event with obstructive hypopnoea progressing toward apnoea; note that the dips in O2 remain shallow. ECG: electrocardiogram.

Zoom

The ultimate health and survival benefits conferred by nocturnal O2 supplementation in patients with chronic HF and sleep apnoea remain to be established.

Cardiac pacing

The results of an initial study suggesting that cardiac pacing might alleviate sleep apnoea [36] were not confirmed by a subsequent study, in which atrial overdrive pacing was delivered by dual chamber pacemakers implanted for the management of bradyarrhythmias, in patients presenting with OSA and without chronic HF [37]. During overdrive atrial pacing, the backup dual chamber pacing rate was programmed between seven and 20 bpm above the mean spontaneous nocturnal heart rate, for 24hours and for 1 month. Furthermore, in a crossover study, 15 patients with OSA in absence of chronic HF who had no indication for cardiac pacing, derived no benefit from 1 night of overdrive atrial pacing [38]. In contrast, a decrease in AHI from 29.3±12.1 to 12.3±4.0 (p <0.004) was measured after 1 week of overdrive atrial pacing in 7/19 (37%) patients presenting with OSA and no chronic HF [39]. These conflicting observations were not explained. Another study of 15 patients presenting with chronic HF and mixed sleep apnoea found a decrease in AHI from 41±20 to 27±15 (p <0.005) in seven patients (47%) during nocturnal overdrive atrial pacing with a dual chamber system [40]. The patients in whom AHI had decreased had a greater proportion of central events than the patients in whom overdrive was ineffective. Importantly, that study, as well as another study that found no effect on OSA and mixed sleep apnoea conferred by up to 7 months of dynamic atrial overdrive pacing in patients with chronic HF [41], had recruited patients with clinical manifestations of OSA.

By contrast, all studies of the effects of CRT on CSA/CSR in patients with chronic HF have shown a significant decrease in AHI, 3 to 6 months after implantation of the system [42, 43, 44, 45, 46, 47]. With respect to the effects of CRT on obstructive respiratory events, the results have been mixed, with either no change [42, 43, 44, 46, 47] or a decrease in AHI [48]. When CRT has alleviating effects on OSA in patients with chronic HF, it might be because the obstructive events are due to haemodynamic fragility instead of pure obstruction of the upper airways. After 3 to 6 months of CRT applied in patients presenting with sleep apnoea, the increase in LVEF ranged between 4 and 14% [42, 43, 44, 45, 46, 47, 48]. The improvement in cardiac function appeared to enhance the respiratory drive, an effect that may decrease the rate of abnormal central respiratory events, which, in turn, increases left ventricular contractility. A correlation has been noted between decrease in CSA/CSR and pulmonary arterial systolic pressure, and increase in LVEF after 3 months of CRT [47]. A decrease in AHI associated with CRT has also been observed in an acute setting [49].

Most studies of CRT and sleep apnoea have been performed without atrial overdrive pacing [42, 44, 45, 46, 47, 49]. When atrial overdrive pacing was applied overnight after 6 months of CRT, in patients with OSA, it conferred no additional therapeutic benefits to those obtained with CRT [48]. Recently, a modest, though significant, additional decrease in AHI of central origin (23.8±16.9 vs 21.5±16.9; p <0.01) was observed when nocturnal atrial overdrive pacing at 15 bpm was added after 3 months of successful CRT [43]. In that study, a decrease in central AHI was measured, from 33.6±14.3 before, to 23.8±16.9 during CRT (p <0.01), before the addition of atrial overdrive pacing. It is noteworthy that neither the new onset nor the worsening of sleep apnoea has been reported during CRT [42, 43, 44, 45, 46, 47, 48, 49]. While CSA/CSR in patients with chronic HF is not, in itself, an indication for CRT, cardiac desynchronization in the presence of CSA/CSR is a strong indication for implanting a CRT system, and the alleviation of sleep apnoea by CRT may be a valid criterion in the evaluation of the response to CRT [50].

Other therapeutic trials

In a randomized, crossover study of 15 patients presenting with chronic HF and CSA/CSR, theophylline, administered in an average dose of 3.3mg/kg for 5 days (mean plasma concentration=11±2mg/mL) decreased mean AHI from 37±23 during placebo treatment, to 18±17 during active treatment (p =0.001) [51]. This therapeutic effect was attributed to a theophylline-induced acceleration of the heart rate, a valid hypothesis as tachycardia is one of the main compensatory mechanisms activated by cardiac insufficiency. Theophylline also activates the central respiratory drive. Its systematic prescription is limited by a high incidence of adverse events, and, while its long-term effects on chronic HF are unknown, cardiac arrhythmias and sudden death associated with the use of theophylline have been reported previously.

Acetazolamide is a diuretic and respiratory stimulant used to treat idiopathic and high-altitude CSA. While other diuretics usually cause metabolic alkalosis, acetazolamide causes metabolic acidosis. The decrease in pH and [HCO3 ] stimulates the chemoreceptors, eliciting respiratory compensation and hypocapnoea due to hyperventilation. The short-term effects of acetazolamide were tested for the treatment of CSA/CSR in 12 patients with chronic HF [52]. The drug was administered in a dose of 3.5 to 4.0mg/kg, 1 hour before bedtime for 6 nights, with a goal of decreasing total venous CO2 by approximately 5mmol/L, as evidence of its effect. This regimen was associated with a mean AHI of 34±20 versus 57±28 during the administration of placebo (p =0.002). Acetazolamide lowered the number of central apnoeas despite the persistence of hypocapnoea. Its administration was associated with a decrease in venous and arterial CO2 and an increase in arterial (H+), along with a decrease in pH and a decrease in arterial (HCO3 ). It was hypothesised that the decrease in PCO2 -driven apnoeic threshold was proportionally greater than the decrease in blood PCO2 . In that study, other effects of acetazolamide, including diuresis and alleviation of pulmonary congestion, were minimal. As is the case with nearly all diuretics, acetazolamide increases the urinary excretion of potassium, and may cause life-threatening hypokalaemia, particularly in patients with chronic HF. The administration of acetazolamide raises other issues, such as the stimulation of the respiratory muscles and hyperventilation, which might accentuate the hypocapnoea observed in patients with chronic HF, who may already be hyperventilating. Furthermore, by inducing metabolic acidosis, acetazolamide may activate the sympathetic nervous system. Finally, because its long-term effects are unknown, acetazolamide cannot be recommended as a routine treatment.

The supplementation of inhaled air by CO2 during sleep-alleviated CSA/CSR in patients with chronic HF, an observation related to the key role played by hypocapnoea in CSA/CSR [53]. In that study, the effects of inhaling room air, CO2 or O2 mixtures were studied in ten patients during stage 2 of a single overnight sleep study. Once the patient was asleep, air was delivered through a facial mask coupled with a three-bag system allowing the selection of one of the three gas mixtures. In a first trial, 10minutes after the onset of central apnoea, a mixture of 4% CO2 , 21% O2 and 76% N2 was delivered. The fraction of inspired CO2 was increased slowly until central apnoeas and hypopnoeas were suppressed. The CO2 inhalation was continued for at least 10minutes before switching the circuit to room air for 10minutes. Thereafter, random trials of CO2 - or O2 -enriched gas mixtures were separated by 10minutes of room air inhalation. O2 was administered in a sufficiently high concentration to increase blood O2 saturation to the level reached during CO2 inhalation. When the patients were not in stage 2 sleep, the system was switched to room air. Transcutaneous PCO2 , closely correlated with PaCO2 , was measured continuously. In the baseline, awake state, arterial PaO2 was 89.8±18.5 mmHg and PaCO2 was 34.3±5.1 mmHg. AHI during room air was 38.7±17.0 versus 2.3±2.9 during CO2 inhalation (p <0.0001). Only six patients underwent both CO2 and O2 inhalation trials, in whom a significant 38% decrease (9.4±7.0) in the apnoea index occurred during O2 inhalation, compared with room air inhalation, which was less pronounced than the 100% decrease (24.9±7.3) caused by CO2 inhalation. Although the inhalation of O2 decreased the apnoea index, it had no significant effect on AHI, indicating either an absence of effect on hypopnoeas, or the progression from apnoeas to hypopnoeas. The time occupied by central respiratory events was 82.9±10.1% during inhalation of room air versus 6.1±9.5% (p =0.01) during CO2 inhalation and 84.5±17.1% during O2 inhalation. The main value of these studies pertain to the physiopathology of CSA/CSR in chronic HF and the role played by hypocapnoea; the routine therapeutic use of supplemental CO2 is not currently recommended. CO2 supplementation may stimulate the sympathetic system prominently, which is undesirable in patients with chronic HF. While increasing the fraction of inspired CO2 by increasing the space of the mask-tube of ventilatory devices is a simple manoeuvre, it is neither suggested nor currently available in clinical practice.

Conclusions

The therapeutic options available for the alleviation of sleep apnoea in patients presenting with chronic HF are summarized in Figure 2. Their ability to decrease AHI is either unpredictable or partial, and, except in the case of OSA, evidence of their effect on morbidity and mortality in this patient population is lacking. The modest improvements in cardiac performance that might be observed during the treatment of sleep apnoea in patients with chronic HF are unlikely to systematically prolong life. In addition, the tolerance of systems using a nasal or facial mask remains a frequent complicating factor, justifying the consideration of all available options in each individual patient.



Figure 2


Figure 2. 

Treatment algorithm for sleep apnoea (SA) in patients with heart failure (HF). SA is considered to be obstructive (OSA), central (CSA) or mixed according to the predominant type of apnoea and hypopnoea. ACEI: angiotensin-converting enzyme inhibitor; CSR: Cheyne-Stokes respiration; CPAP: continuous positive airway pressure; CRT: cardiac resynchronization therapy.

Zoom

Conflicts of interest

None.

References

Morgenthaler T.I., Aurora R.N., Brown T., and al. Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report Sleep 2008 ;  31 : 141-147
Marin J.M., Carrizo S.J., Vicente E., and al. Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study Lancet 2005 ;  365 : 1046-1053 [cross-ref]
Oldenburg O., Lamp B., Faber L., and al. Sleep-disordered breathing in patients with symptomatic heart failure: a contemporary study of prevalence in and characteristics of 700 patients Eur J Heart Fail 2007 ;  9 : 251-257 [cross-ref]
Sin D.D., Fitzgerald F., Parker J.D., and al. Risk factors for central and obstructive sleep apnea in 450 men and women with congestive heart failure Am J Respir Crit Care Med 1999 ;  160 : 1101-1106
Kaneko Y., Floras J.S., Usui K., and al. Cardiovascular effects of continuous positive airway pressure in patients with heart failure and obstructive sleep apnea N Engl J Med 2003 ;  348 : 1233-1241
Kasai T., Narui K., Dohi T., and al. Prognosis of patients with heart failure and obstructive sleep apnea treated with continuous positive airway pressure Chest 2008 ;  133 : 690-696 [cross-ref]
Smith L.A., Vennelle M., Gardner R.S., and al. Auto-titrating continuous positive airway pressure therapy in patients with chronic heart failure and obstructive sleep apnoea: a randomized placebo-controlled trial Eur Heart J 2007 ;  28 : 1221-1227 [cross-ref]
Wang H., Parker J.D., Newton G.E., and al. Influence of obstructive sleep apnea on mortality in patients with heart failure J Am Coll Cardiol 2007 ;  49 : 1625-1631 [cross-ref]
Arzt M., Floras J.S., Logan A.G., and al. Suppression of central sleep apnea by continuous positive airway pressure and transplant-free survival in heart failure: a post hoc analysis of the Canadian Continuous Positive Airway Pressure for Patients with Central Sleep Apnea and Heart Failure Trial (CANPAP) Circulation 2007 ;  115 : 3173-3180 [cross-ref]
Bradley T.D., Logan A.G., Kimoff R.J., and al. Continuous positive airway pressure for central sleep apnea and heart failure N Engl J Med 2005 ;  353 : 2025-2033 [cross-ref]
Kiely J.L., Deegan P., Buckley A., and al. Efficacy of nasal continuous positive airway pressure therapy in chronic heart failure: importance of underlying cardiac rhythm Thorax 1998 ;  53 : 957-962 [cross-ref]
Kanagala R., Murali N.S., Friedman P.A., and al. Obstructive sleep apnea and the recurrence of atrial fibrillation Circulation 2003 ;  107 : 2589-2594
Gami A.S., Hodge D.O., Herges R.M., and al. Obstructive sleep apnea, obesity, and the risk of incident atrial fibrillation J Am Coll Cardiol 2007 ;  49 : 565-571 [cross-ref]
Bradley T.D., Floras J.S. Obstructive sleep apnoea and its cardiovascular consequences Lancet 2009 ;  373 : 82-93 [cross-ref]
Romero-Corral A., Somers V.K., Pellikka P.A., and al. Decreased right and left ventricular myocardial performance in obstructive sleep apnea Chest 2007 ;  132 : 1863-1870 [cross-ref]
Shivalkar B., Van de Heyning C., Kerremans M., and al. Obstructive sleep apnea syndrome: more insights on structural and functional cardiac alterations, and the effects of treatment with continuous positive airway pressure J Am Coll Cardiol 2006 ;  47 : 1433-1439 [cross-ref]
Eckert D.J., Jordan A.S., Merchia P., and al. Central sleep apnea: Pathophysiology and treatment Chest 2007 ;  131 : 595-607 [cross-ref]
Sin D.D., Logan A.G., Fitzgerald F.S., and al. Effects of continuous positive airway pressure on cardiovascular outcomes in heart failure patients with and without Cheyne-Stokes respiration Circulation 2000 ;  102 : 61-66
Philippe C., Stoica-Herman M., Drouot X., and al. Compliance with and effectiveness of adaptive servoventilation versus continuous positive airway pressure in the treatment of Cheyne-Stokes respiration in heart failure over a six month period Heart 2006 ;  92 : 337-342
Morgenthaler T.I., Gay P.C., Gordon N., and al. Adaptive servoventilation versus noninvasive positive pressure ventilation for central, mixed, and complex sleep apnea syndromes Sleep 2007 ;  30 : 468-475
Teschler H., Dohring J., Wang Y.M., and al. Adaptive pressure support servo-ventilation: a novel treatment for Cheyne-Stokes respiration in heart failure Am J Respir Crit Care Med 2001 ;  164 : 614-619
Kasai T., Narui K., Dohi T., and al. Efficacy of nasal bi-level positive airway pressure in congestive heart failure patients with cheyne-stokes respiration and central sleep apnea Circ J 2005 ;  69 : 913-921 [cross-ref]
Kohnlein T., Welte T., Tan L.B., and al. Assisted ventilation for heart failure patients with Cheyne-Stokes respiration Eur Respir J 2002 ;  20 : 934-941 [cross-ref]
Allam J.S., Olson E.J., Gay P.C., and al. Efficacy of adaptive servoventilation in treatment of complex and central sleep apnea syndromes Chest 2007 ;  132 : 1839-1846 [cross-ref]
Kasai T., Narui K., Dohi T., and al. First experience of using new adaptive servo-ventilation device for Cheyne-Stokes respiration with central sleep apnea among Japanese patients with congestive heart failure: report of four clinical cases Circ J 2006 ;  70 : 1148-1154 [cross-ref]
Pepperell J.C., Maskell N.A., Jones D.R., and al. A randomized controlled trial of adaptive ventilation for Cheyne-Stokes breathing in heart failure Am J Respir Crit Care Med 2003 ;  168 : 1109-1114 [cross-ref]
Walsh J.T., Andrews R., Starling R., and al. Effects of captopril and oxygen on sleep apnoea in patients with mild to moderate congestive cardiac failure Br Heart J 1995 ;  73 : 237-241 [cross-ref]
Tamura A., Kawano Y., Naono S., and al. Relationship between beta-blocker treatment and the severity of central sleep apnea in chronic heart failure Chest 2007 ;  131 : 130-135 [cross-ref]
Tamura A., Kawano Y., Kadota J. Carvedilol reduces the severity of central sleep apnea in chronic heart failure Circ J 2009 ;  73 : 295-298 [cross-ref]
Arzt M., Schulz M., Wensel R., and al. Nocturnal continuous positive airway pressure improves ventilatory efficiency during exercise in patients with chronic heart failure Chest 2005 ;  127 : 794-802 [cross-ref]
Sasayama S., Izumi T., Seino Y., and al. Effects of nocturnal oxygen therapy on outcome measures in patients with chronic heart failure and cheyne-stokes respiration Circ J 2006 ;  70 : 1-7 [cross-ref]
Sasayama S., Izumi T., Matsuzaki M., and al. Improvement of quality of life with nocturnal oxygen therapy in heart failure patients with central sleep apnea Circ J 2009 ;  73 : 1255-1262 [cross-ref]
Xie A., Skatrud J.B., Puleo D.S., and al. Exposure to hypoxia produces long-lasting sympathetic activation in humans J Appl Physiol 2001 ;  91 : 1555-1562
Jelic S., Padeletti M., Kawut S.M., and al. Inflammation, oxidative stress, and repair capacity of the vascular endothelium in obstructive sleep apnea Circulation 2008 ;  117 : 2270-2278 [cross-ref]
Andreas S., Plock E.H., Heindl S., and al. Nasal oxygen effects on arterial carbon dioxide pressure and heart rate in chronic heart failure Am J Cardiol 1999 ;  83 : 795-798A10.  [cross-ref]
Garrigue S., Bordier P., Jais P., and al. Benefit of atrial pacing in sleep apnea syndrome N Engl J Med 2002 ;  346 : 404-412 [cross-ref]
Simantirakis E.N., Schiza S.E., Chrysostomakis S.I., and al. Atrial overdrive pacing for the obstructive sleep apnea-hypopnea syndrome N Engl J Med 2005 ;  353 : 2568-2577 [cross-ref]
Krahn A.D., Yee R., Erickson M.K., and al. Physiologic pacing in patients with obstructive sleep apnea: a prospective, randomized crossover trial J Am Coll Cardiol 2006 ;  47 : 379-383 [cross-ref]
Melzer C., Fietze I., Duru F., and al. Nocturnal overdrive pacing for the treatment of sleep apnea syndrome Sleep 2006 ;  29 : 1197-1202
Sharafkhaneh A., Sharafkhaneh H., Bredikus A., and al. Effect of atrial overdrive pacing on obstructive sleep apnea in patients with systolic heart failure Sleep Med 2007 ;  8 : 31-36 [cross-ref]
Sinha A.M., Bauer A., Skobel E.C., and al. Long-term effects of dynamic atrial overdrive pacing on sleep-related breathing disorders in pacemaker or cardioverter defibrillator recipients Pacing Clin Electrophysiol 2009 ;  32 (Suppl. 1) : S219-S222 [cross-ref]
Gabor J.Y., Newman D.A., Barnard-Roberts V., and al. Improvement in Cheyne-Stokes respiration following cardiac resynchronisation therapy Eur Respir J 2005 ;  26 : 95-100 [cross-ref]
Luthje L., Renner B., Kessels R., and al. Cardiac resynchronization therapy and atrial overdrive pacing for the treatment of central sleep apnoea Eur J Heart Fail 2009 ;  11 : 273-280 [cross-ref]
Oldenburg O., Faber L., Vogt J., and al. Influence of cardiac resynchronisation therapy on different types of sleep disordered breathing Eur J Heart Fail 2007 ;  9 : 820-826 [cross-ref]
Sinha A.M., Skobel E.C., Breithardt O.A., and al. Cardiac resynchronization therapy improves central sleep apnea and Cheyne-Stokes respiration in patients with chronic heart failure J Am Coll Cardiol 2004 ;  44 : 68-71 [cross-ref]
Skobel E.C., Sinha A.M., Norra C., and al. Effect of cardiac resynchronization therapy on sleep quality, quality of life, and symptomatic depression in patients with chronic heart failure and Cheyne-Stokes respiration Sleep Breath 2005 ;  9 : 159-166 [cross-ref]
Yiu K.H., Lee K.L., Lau C.P., and al. Alleviation of pulmonary hypertension by cardiac resynchronization therapy is associated with improvement in central sleep apnea Pacing Clin Electrophysiol 2008 ;  31 : 1522-1527 [cross-ref]
Stanchina M.L., Ellison K., Malhotra A., and al. The impact of cardiac resynchronization therapy on obstructive sleep apnea in heart failure patients: a pilot study Chest 2007 ;  132 : 433-439 [cross-ref]
Kara T., Novak M., Nykodym J., and al. Short-term effects of cardiac resynchronization therapy on sleep-disordered breathing in patients with systolic heart failure Chest 2008 ;  134 : 87-93 [cross-ref]
Sredniawa B., Lenarczyk R., Kowalski O., and al. Sleep apnoea as a predictor of mid- and long-term outcome in patients undergoing cardiac resynchronization therapy Europace 2009 ;  11 : 106-114
Javaheri S., Parker T.J., Wexler L., and al. Effect of theophylline on sleep-disordered breathing in heart failure N Engl J Med 1996 ;  335 : 562-567 [cross-ref]
Javaheri S. Acetazolamide improves central sleep apnea in heart failure: a double-blind, prospective study Am J Respir Crit Care Med 2006 ;  173 : 234-237
Lorenzi-Filho G., Rankin F., Bies I., and al. Effects of inhaled carbon dioxide and oxygen on cheyne-stokes respiration in patients with heart failure Am J Respir Crit Care Med 1999 ;  159 : 1490-1498



© 2009  Elsevier Masson SAS. All Rights Reserved.
EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline