Mesure de l'angle de couverture antérieure de la tête fémorale chez 102 volontaires
The anterior center edge angle: a study of 102 volunteers

Abtullah  Milcan a * ,  Altan  Yildiz b ,  Volkan  Öztuna MD a ,  Metin Manouchehr  Eskandari a ,  Güscedil;a  Scedil;ahin c ,  Fehmi  Kuyurtar a
a Service de chirurgie orthopédique et traumatologique, école de médecine, université de Mersin, Turquie 
b Service de radiologie, école de médecine, université de Mersin, Turquie 
c Service de médecine physique et réadaptation, école de médecine, université de Mersin, Turquie 

*Auteur correspondant. Barbaros mahallesi, 2186 sok; Kadioglu apt. no 2, Daire 13, 33150 Mersin,Turkey (Turquie).
@@#100979@@

Objectif. - Mesurer la valeur de l'angle de couverture antérieure de la tête fémorale, appelée ici VCE, dans une population témoin.

Patients et méthodes. - La mesure de l'angle VCE sur le faux profil de Lequesne a été effectuée, entre octobre 2000 et octobre 2001, aux 2 hanches dans une population témoin de 102 volontaires comprenant 79 femmes et 23 hommes. Les radiographies montrant une coxopathie dégénérative et celles de mauvaise qualité ont été exclues de l'étude. En conséquence, 181 radiographies ont été analysées.

Résultats. - Chacune des 181 radiographies a été analysée par 2 examinateurs, un chirurgien orthopédiste et un radiologue, et dans chaque cas à 2 reprises à 24 h d'intervalle ; ceci, selon une même méthodologie standardisée avec le même rapporteur. La valeur moyenne de l'angle VCE était de 49,27 ± 7,77° (extrêmes : 24,75 et 68,75). Cette valeur moyenne est différente de celles observées dans les études antérieures. Nous n'avons pas trouvé de différence significative inter- ou intra-observateur.

Conclusion. - Nos résultats pourraient servir à déterminer un nouveau paramètre pour évaluer la couverture antérieure de la tête fémorale. Chez les patients ayant une dysplasie cotyloïdienne avec un défaut de couverture antérieure, ce paramètre pourrait être utile pour porter les indications opératoires, pour déterminer la technique opératoire et pour évaluer les résultats postopératoires.

Mots clés  : Faux profil de Lequesne ; Dysplasie acétabulaire ; Dysplasie de hanche.

Abstract

Objectives. - To measure the anterior center edge (VCE) angle that reflects anterior coverage of the femoral head.

Patients and methods. - False profile views of both hips of 102 volunteers, 23 male and 79 female, were taken between october 2000 and october 2001. Radiographs with evidence of degenerative hip disease and those with poor image quality were excluded from the study. This left 181 radiographs.

Results. - An orthopedic surgeon and a radiologist used a standard protractor to examine each of the 181 radiographs twice, at an interval of 24 h. The mean VCE angle was 49.27 ± 7.77° (range, 24.75-68.75), a value different from those found in previous studies. No significant intra-observer or interobserver differences were found.

Conclusions. - Our findings may contribute to the determination of a new parameter for evaluating anterior femoral head covering. In patients with acetabular dysplasia and deficient anterior coverage, this parameter may prove useful for selecting patients for surgery, planning the procedure, and evaluating postoperative results.

Mots clés  : False profile view ; Acetabular dysplasia ; Hip dysplasia.


1  Pour citer cet article, utiliser ce titre en anglais et sa référence dans le même volume de Joint Bone Spine.




© 2003  Elsevier SAS. All Rights Reserved.

EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline