Spatial distribution of neo-intimal hyperplasia 6 months after zotarolimus-eluting stent implantation, analysed by optical coherence tomography
Distribution spatiale de l’hyperplasie néo-intimale six mois après implantation de stents actifs au zotarolimus analysée par tomographie par cohérence optique
 

Figure 1




Figure 1 : 

Stent analysis on optical coherence tomography millimetric images: (a) qualitative strut analysis (A. covered; B. non-covered; C. malapposed; D. facing collateral); (b) quantitative analysis (neointimal hyperplasia area [green]; lumen area [red]; coverage thickness per strut [red arrows]); (c) longitudinal analysis in five segments of equal length (P2: proximal; P1: proximal-medial; M: medial; D1: distal-medial; D2: distal).


Figure 2




Figure 2 : 

Relationship between strut coverage thickness (μm), neointimal hyperplasia (NIH) obstruction (%) and non-covered strut ratio, studied on 745 optical coherence tomography slices (699 slices with all struts covered; 28 slices with non-covered strut [NCS] ratio<0.15; 12 slices with NCS ratio between 0.15 and 0.30; six slices with NCS ratio>0.30).


Figure 3




Figure 3 : 

Spatial distribution of neointimal hyperplasia (NIH) and strut coverage, 6 months after zotarolimus-eluting stent implantation (n =42), from quantitative optical coherence tomography analysis. A. Mean stent area, NIH area (NIHA) and lumen area (LA) (mm2) in all 745 slices; mean areas in five longitudinal stent segments (P2: proximal; P1: proximal-medial; M: medial; D1: distal-medial; D2: distal). B. Mean strut coverage thickness (μm) in all cross sections and in five longitudinal stent segments (bars), and neointimal hyperplasia (NIH) percentage obstruction (points). C. Mean non-covered strut ratio in all cross sections and in five longitudinal stent segments.


Figure 4




Figure 4 : 

Relationship between mean strut coverage thickness, neointimal hyperplasia (NIH) obstruction measured by optical coherence tomography and stent length (A, B) and stent diameter (C, D), 6 months after zotarolimus-eluting stent implantation (n =42).

EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline