Biomécanique de la rupture des membranes fœtales. Les membranes fœtales sont plus résistantes avant terme qu’à terme - 04/06/11

Doi : 10.1016/j.gyobfe.2011.04.007 
N. Rangaswamy a, A. Abdelrahim a, R.M. Moore a, L. Uyen c, B.M. Mercer b, J.M. Mansour c, D. Kumar a, J. Sawady d, J.J. Moore a, , b
a Department of pediatrics, MetroHealth medical center, Case Western Reserve University, 2500 MetroHealth-Drive, Cleveland, Ohio, États-Unis 
b Reproductive biology, MetroHealth medical center, Case Western Reserve University, 2500 MetroHealth-Drive, Cleveland, Ohio, États-Unis 
c Mechanical and aerospace engineering, MetroHealth medical center, Case Western Reserve University, 2500 MetroHealth-Drive, Cleveland, Ohio, États-Unis 
d The department of pathology, MetroHealth medical center, Case Western Reserve University, 2500 MetroHealth-Drive, Cleveland, Ohio, États-Unis 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 4
Vidéos 0
Autres 0

Résumé

Le but de cette étude était de déterminer les caractéristiques biomécaniques des membranes fœtales humaines (FM) durant la gestation. Ces propriétés, notamment la force et le travail, produisant la rupture ont été déterminées pour 115 d’entre elles de 23–41 semaines de gestation. Les domaines de FM à proximité immédiate des zones les plus et les moins résistantes testées ont été échantillonnés pour l’analyse histomorphométrique. Les données cliniques sur les patientes dont les FM ont été examinées ont également été recueillies. Les FM de moins de 28 semaines de gestation sont associées à une incidence plus élevée de décollement placentaire et de chorioamniotite. Sur le plan topographique, les FM à tous les stades de gestation ont des caractéristiques biomécaniques hétérogènes distinctes des zones fragiles quant à leur résistance. La plupart des membranes de préterme a une plus forte résistance. La force et le travail de rupture des FM diminuent avec l’âge gestationnel. Cette diminution est spectaculaire à plus de 38 semaines de gestation. La couche amnio-choriale est plus mince dans les zones fragiles par rapport aux zones résistantes. Les FM de préterme sont plus résistantes mais elles sont aussi très hétérogènes. L’augmentation progressive de la fragilité des FM avec la gestation atteint un maximum à 38 semaines. Les zones de faiblesses sont plus minces que les parties les plus résistantes. On ne peut affirmer que la différence d’épaisseur soit suffisante pour expliquer des différences de résistance des MF.

Le texte complet de cet article est disponible en PDF.

Abstract

The purpose of this study was to determine the biomechanical characteristics of human fetal membranes (FM) throughout gestation. Biomechanical properties were determined for 115 FM of 23–41weeks gestation using our previously described methodology. The areas of membrane immediately adjacent to the strongest and weakest tested spots were sampled for histomorphometric analysis. Clinical data on the patients whose FM were examined were also collected. FM less than 28 weeks gestation were associated with higher incidence of abruption and chorioamnionitis. Topographically FM at all gestations had heterogeneous biomechanical characteristics over their surfaces with distinct weak areas. The most premature membranes were the strongest. FM strength represented by rupture force and work to rupture decreased with increasing gestation in both weak and strong regions of FM. This decrease in FM strength was most dramatic at more than 38 weeks gestation. The FM component amnion-chorion sublayers were thinner in the weak areas compared to strong areas. Compared to term FM, preterm FM are stronger but have similar heterogeneous weak and strong areas. Following a gradual increase in FM weakness with increasing gestation, there is a major drop-off at term 38 weeks gestation. The FM weak areas are thinner than the stronger areas. Whether the difference in thickness is enough to account for the strength differences is unknown.

Le texte complet de cet article est disponible en PDF.

Mots clés : Membranes fœtales, Grossesse, Rupture, Prématurité, Terme, Biomécanique

Keywords : Fetal membranes, Pregnancy, Rupture, Prematurity, Term, Biomechanics


Plan


 Support : NIH HD 48476 to JJM.
 Article traduit de l’anglais par J.-C. Challier.


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 39 - N° 6

P. 373-377 - juin 2011 Retour au numéro
Article précédent Article précédent
  • Étude de la voie des rétinoïdes au sein des membranes fœtales humaines : mise en évidence de gènes cibles
  • L. Blanchon, G. Marceau, V. Borel, C. Prat, A. Herbet, D. Bouvier, D. Gallot, V. Sapin
| Article suivant Article suivant
  • Traitement de la rupture iatrogène des membranes fœtales par « patch » amniotique
  • J. Deprest, T. Van Mieghem, M.-P. Emonds, J. Richter, P. De Koninck, S. Zia, J. Van Keirsbilck, I. Sandaite, L. Olde Damink, L. Lewi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.