S'abonner

Morphologic Validation of Reperfused Hemorrhagic Myocardial Infarction by Cardiovascular Magnetic Resonance - 16/08/11

Doi : 10.1016/j.amjcard.2007.05.062 
Cristina Basso, MD, PhD a, Francesco Corbetti, MD b, , Caterina Silva, MD, PhD c, Aierken Abudureheman, MD, PhD a, Carmelo Lacognata, MD b, Luisa Cacciavillani, MD c, Giuseppe Tarantini, MD, PhD c, Martina Perazzolo Marra, MD c, Angelo Ramondo, MD c, Gaetano Thiene, MD a, Sabino Iliceto, MD a
a Department of Medic-Diagnostic Sciences and Special Therapies, University of Padua Medical School, Padua, Italy 
b Service of Radiology, University of Padua Medical School, Padua, Italy 
c Department of Cardio, Thoracic, and Vascular Sciences, University of Padua Medical School, Padua, Italy. 

Corresponding author: Tel: 0039-049-8211982; fax: 0039-049-8272284.

Résumé

The purposes of this study were to assess the ex vivo cardiovascular magnetic resonance (CMR) signals of pathologically proved hemorrhagic myocardial infarction (MI) and to correlate these with in vivo CMR findings. Late gadolinium hypoenhancement within a hyperenhanced area in reperfused acute MI is ascribed to severe microvascular obstruction. The hearts of 2 patients, who died from cardiogenic shock after acute MIs and who had undergone coronary recanalization and in vivo CMR, were examined by T2 and T1 late enhancement sequences as well as by gross and histologic investigation. Four corresponding short-axis slices of each cardiac specimen from the base to the left ventricular apex were selected to assess the extent of MI and hemorrhage and were compared with the in vivo T2 and late enhancement CMR scans. On pathologic examination, the extent of MI was 57 ± 30% and 44 ± 24%, and the extent of hemorrhage was 23 ± 13% and 19 ± 8% of the left ventricular area, respectively, showing progressive increases from the base to the apex. The low-signal intensity areas observed by ex vivo T2 CMR strongly correlated with the hemorrhage quantified on histology (R = 0.93, p = 0.0007). Using ex vivo late gadolinium sequences, bright areas surrounded by thin dark rims, consistent with magnetic susceptibility effects, were detected, corresponding with hemorrhage. On in vivo CMR images, low-signal intensity and hyperintense areas with peripheral susceptibility artifacts were observed within the MI core on T2 and late gadolinium sequences, respectively. In conclusion, in reperfused MI, CMR hypointense T2 signal and susceptibility effects within the late gadolinium hypoenhanced areas are consistent with interstitial hemorrhage due to irreversible vascular injury, as proved by pathologic study.

Le texte complet de cet article est disponible en PDF.

Plan


 This work was supported by the Registry of Cardio-Cerebrovascular Pathology, Veneto Region, Venice, Italy.


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 100 - N° 8

P. 1322-1327 - octobre 2007 Retour au numéro
Article précédent Article précédent
  • A Prescription for Improving National Health Care
  • Fred Hassan
| Article suivant Article suivant
  • Aneurysms of Sinus of Valsalva
  • Tsung O. Cheng

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.