The Association of Contact Lens Solution Use and Acanthamoeba Keratitis - 21/08/11

Doi : 10.1016/j.ajo.2007.05.029 
Charlotte E. Joslin a, b, , Elmer Y. Tu a, Megan E. Shoff c, Gregory C. Booton d, Paul A. Fuerst c, Timothy T. McMahon a, Robert J. Anderson b, Mark S. Dworkin b, Joel Sugar a, Faith G. Davis b, Leslie T. Stayner b
a Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, Illinois 
b Division of Epidemiology and Biostatistics, School of Public Health, University of Illinois at Chicago, Chicago, Illinois. 
c The Departments of Evolution, Ecology, and Organismal Biology, The Ohio State University, Department of Columbus, Columbus, Ohio 
d Molecular Genetics, The Ohio State University, Department of Columbus, Columbus, Ohio. 

Inquiries to Charlotte E. Joslin, University of Illinois at Chicago, Department of Ophthalmology and Visual Sciences, 1855 W. Taylor Street, Ste. 3164, Chicago, IL 60612

Résumé

Purpose

To investigate Acanthamoeba keratitis (AK) risk factors. Diagnosis of AK, a rare but serious corneal infection, has recently increased significantly at the University of Illinois at Chicago (UIC) Cornea Service.

Design

Retrospective case-control study.

Methods

settings: University, tertiary care hospital. patients: Fifty-five AK cases with contact lens use were diagnosed between May 1, 2003 and September 15, 2006. Clinic-matched controls with contact lens use were recruited. Subjects completed surveys targeting lens hygiene, contact lens solution use, and water exposure. main outcome measure: Acanthamoeba keratitis.

Results

Thirty-nine (73.6%) cases and 113 (65.3%) controls participated; 38 cases had complete contact lens data. Thirty-five of 38 cases (92.1%) and 47 of 100 controls (47.0%) used soft lenses. Analysis was performed on 30 cases and 39 controls with matched pairs with soft lens use. Exclusive use of Advance Medical Optics (AMO) Complete MoisturePlus Multi-Purpose Solution was independently associated with AK in multivariable analysis (55.2% vs 10.5%; odds ratio [OR], 16.67; 95% confidence interval [CI] 2.11 to 162.63; P = .008). However, 38.8% of cases reported no use of AMO Complete MoisturePlus Multi-Purpose Solution either alone or in combination with other solutions. Although not statistically significant, additional hygiene-related variables (solution “reuse,” lack of “rubbing,” and showering with lenses) suggest a pattern of risk.

Conclusions

AMO Complete MoisturePlus Multi-Purpose Solution use is independently associated with AK among soft contact lens users. However, it does not explain all cases, suggesting additional factors. Further research into environmental risk factors and hygiene practices is warranted, especially considering this is the second outbreak of an atypical, contact lens-related infection.

Le texte complet de cet article est disponible en PDF.

Plan


 See accompanying Editorial on page 292.


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 144 - N° 2

P. 169 - août 2007 Retour au numéro
Article précédent Article précédent
  • Table of Contents
| Article suivant Article suivant
  • Long-term Results of Thin Corneas After Refractive Laser Surgery
  • George D. Kymionis, Dimitrios Bouzoukis, Vasilios Diakonis, Nikolaos Tsiklis, Eirineos Gkenos, Aristofanis I. Pallikaris, JoAnn A. Giaconi, Sonia H. Yoo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.