S'abonner

Enhanced renal parenchymal cryoablation with novel 17-gauge cryoprobes - 23/08/11

Doi : 10.1016/j.urology.2004.02.033 
Caroline D Ames a, Richard Vanlangendonck b, Ramakrishna Venkatesh a, Froylan C Gonzales a, Sejal Quayle a, Yan Yan a, Peter A Humphrey c, Jaime Landman a,
a Division of Urology, Washington University School of Medicine, St. Louis, Missouri, USA 
c Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, Missouri, USA 
b Ochsner Clinic Foundation, New Orleans, Louisiana, USA 

*Reprint requests: Jaime Landman, M.D., Division of Urology, Washington University School of Medicine, 4960 Children's Place, Campus Box 8242, St. Louis, MO 63110, USA

Abstract

Objectives

To evaluate novel, 17-gauge cryoprobes with a modified heat exchange mechanism to evaluate the area of ablation that could be achieved with 17-gauge (1.47-mm) cryoprobes.

Methods

Eleven pigs were divided into four groups. Each animal underwent laparoscopic creation of three cryolesions with an ellipical iceball-generating 17-gauge cryoprobe (group 1), one that generates a teardrop-shaped iceball (group 2), a template of three standard 17-gauge cryoprobes (group 3), or a single, standard, large-caliber (3.4-mm) cryoprobe (group 4). Each cryolesion was created with a standard double-freeze cycle. Intraoperative ultrasonography was used to measure the maximal iceball dimensions, and the renal temperatures were measured with a thermocouple. The animals were killed after 14 days. The gross lesion size and histopathologic area of necrosis were documented.

Results

The mean temperature for the surrounding renal parenchyma was not significantly different among the groups. No statistically significant difference was noted in the size of the gross or histopathologic lesions created among the four groups. The gross lesion size correlated statistically significantly with the histologic area of necrosis (P <0.01).

Conclusions

Despite the diminutive size of the 17-gauge cryoprobes tested, the probes ablated tissue volumes equivalent to that ablated using the larger, standard 3.4-mm cryoprobe or a configuration of three standard 17-gauge cryoprobes. These novel 17-gauge cryoprobes may facilitate ablation of small and medium-size renal tumors and may have expanded application for percutaneous ablation owing to the decreased risk of hemorrhage.

Le texte complet de cet article est disponible en PDF.

Plan


 J. Landman is a study investigator funded by Oncura Medical.


© 2004  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 64 - N° 1

P. 173-175 - juillet 2004 Retour au numéro
Article précédent Article précédent
  • Inhibitory effect of the antidepressant St. John's Wort (hypericum perforatum) on rat bladder contractility in vitro
  • Raffaele Capasso, Francesca Borrelli, Francesco Capasso, Nicola Mascolo, Angelo A Izzo
| Article suivant Article suivant
  • Positive correlation between allelic loss at chromosome 14q24-31 and poor prognosis of patients with renal cell carcinoma
  • Haruki Kaku, Sachio Ito, Shin Ebara, Mamoru Ouchida, Yasutomo Nasu, Tomoyasu Tsushima, Hiromi Kumon, Kenji Shimizu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.