S'abonner

Optical coherence tomography (oct) macular and peripapillary retinal nerve fiber layer measurements and automated visual fields - 25/08/11

Doi : 10.1016/j.ajo.2004.03.019 
Gadi Wollstein, MD a, b, Joel S. Schuman, MD a, b, , Lori L. Price, MS c, Ali Aydin, MD b, Siobahn A. Beaton, BA a, b, Paul C. Stark, ScD c, James G. Fujimoto, PhD d, Hiroshi Ishikawa, MD a, b
a UPMC Eye Center, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA (G.W., J.S.S., S.A.B., H.I.) 
b New England Eye Center, Tufts-New England Medical Center, Tufts University School of Medicine, Boston, Massachusetts, USA (G.W., J.S.S., A.A., S.A.B., H.I.) 
c Biostatistics Research Center, Division of Clinical Care Research, Tufts-New England Medical Center, Tufts University School of Medicine, Boston, Massachusetts, USA (L.L.P., P.C.S.) 
d Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA (J.G.F.) 

*Inquiries to Joel S. Schuman, MD, UPMC Eye Center, University of Pittsburgh School of Medicine, 203 Lothrop Street, Eye and Ear Institute, Suite 816, Pittsburgh, PA 15213, USA; fax: 412-647-5119

Abstract

Purpose

To investigate the structure-function relationship between optical coherence tomography (OCT) macular retinal and peripapillary nerve fiber layer (NFL) thickness and automated visual field (VF) findings.

Design

Cross-sectional observational study.

Methods

Retrospective institutional study where 150 consecutive eyes (101 subjects) from a glaucoma service were included. All the participants had full ophthalmic evaluation, VF testing and prototype OCT scanning at the same visit. Orthogonal OCT macular analysis was obtained to maximize the sampling of the area of interest. Pearson age-adjusted correlation was determined between macular retinal thickness and peripapillary NFL thickness. Area under the receiver operator characteristics (AROC) curves for the association between macular retinal thickness and peripapillary NFL thickness and VF findings were calculated in a subgroup of eyes without VF defect and eyes with VF defect confined to one hemifield.

Results

The correlation between macular retinal and peripapillary NFL measurements ranged between r = .27 to .54 for quadrants, .44 to .55 for hemiretina, and .52 for the overall mean. Areas under the receiver operator characteristics for macular thickness were higher in areas corresponding to the VF defect location than the noncorresponding locations. Areas under the receiver operator characteristics for peripapillary NFL thickness were higher than for the macular retinal thickness. Including both macular retinal thickness and peripapillary NFL thickness measurements in the logistic regression model yielded AROCs (range: .69 − .77) similar to those found for the peripapillary NFL alone.

Conclusion

Macular retinal thickness, as measured by OCT, was capable of detecting glaucomatous damage and corresponded with peripapillary NFL thickness; however, peripapillary NFL thickness had higher sensitivity and specificity for the detection of VF abnormalities.

Le texte complet de cet article est disponible en PDF.

Plan


 Biosketches and/or additional material at www.ajo.com


© 2004  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 138 - N° 2

P. 218-225 - août 2004 Retour au numéro
Article précédent Article précédent
  • Endothelial cell density after posterior lamellar keratoplasty (Melles techniques): 3 years follow-up
  • Bart Van Dooren, Paul G.H. Mulder, Carla P. Nieuwendaal, W.H. Beekhuis, Gerrit R.J. Melles
| Article suivant Article suivant
  • A laboratory evaluation of antibiotic therapy for ciprofloxacin-resistant pseudomonas aeruginosa
  • Michelle K. Rhee, Regis P. Kowalski, Eric G. Romanowski, Francis S. Mah, David C. Ritterband, Y.Jerold Gordon

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.