S'abonner

A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses - 26/08/11

Doi : 10.1016/S0002-9394(03)00418-5 
Trevin R Wallin, BS a, Michael Hinckley, BA a, Christian Nilson, MD a, Randall J Olson, MD a,
a Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA 

*Inquiries to Randall J. Olson, MD, Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, 50 North Medical Drive, Salt Lake City, USA, UT 84132; fax: (801) 581-3357

Abstract

Purpose

To determine the clinical differences between three-piece (3P) and single-piece (SP) truncated hydrophobic acrylic intraocular lenses (IOL).

Design

Retrospective cohort clinical study.

Methods

The setting was an academic clinical practice. The patient population consisted of subjects without confounding comorbidity that could effect central vision with at least 1-year follow-up after uncomplicated surgical placement of 3P or SP IOLs in the capsular bag and at least 20/25 best-corrected postoperative vision documented. Observation procedures were as follows: logarithm of the minimal angle of resolution (LogMAR) visual acuity (uncorrected and best corrected), digital retroillumination photographs to ascertain posterior capsular opacification (PCO), anterior capsular opacification (ACO), IOL centration, and refractive stability by comparing this refraction with the early postoperative refraction. Patients completed a dysphotopsia questionnaire. Main outcome measures were as follows: LogMAR visual acuity (uncorrected and best corrected), PCO, ACO, IOL centration, refractive stability, and dysphotopsia outcomes comparing 3P and SP.

Results

Seventy-five patients were enrolled (36 3P and 39 SP). Corrected and uncorrected visual acuity, refractive stability, and IOL centration were similar. Single piece truncated hydrophobic acrylic intraocular lenses had more PCO (P = .013), less ACO (P = .001), less central flash looking at a peripheral light (P = .044), and less unwanted images to the side of a light source (P = .025).

Conclusions

Although similar in centration and refractive stability, SP has more PCO, less ACO, and less dysphotopsia than 3P.

Le texte complet de cet article est disponible en PDF.

Plan


 InternetAdvance publication at ajo.com April 22, 2003.
This study was supported in part by a grant from Research to Prevent Blindness, Inc., New York, New York, to the Department of Ophthalmology and Visual Sciences, University of Utah. Dr. Olson is a consultant for Advanced Medical Optics.


© 2003  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 136 - N° 4

P. 614-619 - octobre 2003 Retour au numéro
Article précédent Article précédent
  • Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans
  • Mitsugu Shimmyo, Anna J Ross, Anna Moy, Ramin Mostafavi
| Article suivant Article suivant
  • The course of moderate amblyopia treated with patching in children: experience of the amblyopia treatment study
  • Pediatric Eye Disease Investigator Group * * * e1

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.