S'abonner

Évaluation de l’état et du devenir du matériel de base destiné à la prise en charge du nouveau-né à la naissance dans les structures sanitaires périphériques au Sénégal, après un recul de trois ans - 30/03/12

Doi : 10.1016/j.arcped.2012.01.009 
A. Sylla a, , S. Diouf a, A. Thiam b, I. Narayanan b, M. Gueye c, A.L. Fall d, N.R. Diagne-Gueye d, C. Moreira a, O. Ndiaye c, M.G. Sall a
a CHU Aristide-Le-Dantec, Dakar, Sénégal 
b Basics HQ, Dakar, Sénégal 
c CHU Abass Ndao, Dakar, Sénégal 
d Hôpital d’Enfants Albert-Royer, Dakar, Sénégal 

Auteur correspondant. Service universitaire de pédiatrie, université Cheikh Anta Diop, Dakar, Sénégal.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 0
Vidéos 0
Autres 0

Résumé

Contexte

La mortalité périnatale est un problème majeur de santé publique au Sénégal. Les principales causes sont l’infection, la prématurité, l’asphyxie à la naissance. Dans le souci de la réduire, des structures de santé ont été équipées en matériel de base pour la prise en charge du nouveau-né et leurs personnels formés aux soins essentiels. Trois années après cette initiative, nous nous proposons dans cette étude d’évaluer l’état et le devenir de ces équipements.

Matériel et méthode

L’évaluation conduite du 16 mars au 3 avril 2009 a reposé sur l’observation et l’interview, sur un échantillon de structures sanitaires tirées au sort.

Résultats

Les ballons de ventilation et masques étaient disponibles dans 87 % des structures de santé quel que soit le niveau (60/69). Ils étaient quasiment tous fonctionnels. Dans plus de la moitié des postes de santé (20/38), ils n’étaient jamais utilisés parce que le personnel était nouveau et non formé. Un aspirateur généralement adapté pour les nouveau-nés (pression négative de 100mm Hg) était disponible dans 85 % des structures (59/69). L’entretien du matériel était globalement satisfaisant car les réservoirs étaient propres le plus souvent. Quant aux sondes d’aspiration, elles étaient constamment disponibles avec quelques cas de rupture de stock beaucoup plus notoires dans les centres de santé. La table chauffante n’était disponible que dans une structure sur deux (36/69). Quinze tables n’étaient pas conformes aux spécifications initiales.

Conclusion

Au terme de cette évaluation, il ressort que l’équipement de base destiné à la prise en charge de l’asphyxie des nouveau-nés et mis en place pour l’essentiel depuis trois ans, était globalement disponible, fonctionnel et bien entretenu. La mise en place de cet équipement semble être une stratégie pérenne pouvant faire l’objet d’une généralisation, en vue de contribuer à faire baisser la mortalité néonatale.

Le texte complet de cet article est disponible en PDF.

Summary

Background

Neonatal mortality is a major public health problem. The main causes are infections, prematurity and asphyxia at birth. In view of reducing this high mortality, primary healthcare facilities were equipped with basic equipment for the care of newborns and their key workers were trained in essential newborn care. Three years after this implementation, the present study assesses the state and conditions of use of this basic equipment intended for taking care of newborns at birth.

Method

This assessment was conducted from 16 March to 3 April 2009. It was based on observations and interviews on a sample of healthcare facilities.

Results

Healthcare facilities were generally equipped with ventilator bags and masks (87%) (60/69). In more than half of the healthcare centers (20/38), they were not used often because the workers were renewed and not educated in their use. They were practically all in good condition. Eighty-five percent (59/69) of healthcare facilities had at least one aspirator, generally adapted to newborns (negative pressure, 100mmHg). The maintenance of the material was globally satisfactory because the aspirator bottles were most often clean. As for the aspirator tubes, they were always available but a few cases of supply rupture were observed in some healthcare centers. The warming table was available in only 52% (36/69) of healthcare facilities. Fifteen tables did not comply with initial specifications.

Conclusion

This assessment highlights that the basic equipment intended for newborn care was generally available, functional and maintained well after 3years. This strategy could be scaled up in order to contribute to reducing the newborn mortality.

Le texte complet de cet article est disponible en PDF.

Plan


© 2012  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 19 - N° 4

P. 355-360 - avril 2012 Retour au numéro
Article précédent Article précédent
  • Faire face à une naissance sans nom. À propos des parents d’enfants nés avec une variation anatomique des organes génitaux
  • K. Gueniche, M. Polak
| Article suivant Article suivant
  • Volvulus prénatal du grêle : risque vital immédiat mais bon pronostic à long terme
  • R. Raherison, C. Grosos, J. Lemale, E. Blondiaux, N. Sabourdin, S. Dahan, J. Rosenblatt, J. Guilbert, J.-M. Jouannic, D. Mitanchez, G. Audry, F. Auber

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.