S'abonner

Flammability of topical preparations and surgical dressings in cutaneous and laser surgery: A controlled simulation study - 14/09/12

Doi : 10.1016/j.jaad.2012.04.026 
Katharine Arefiev, MD a, Melanie Warycha, MD b, Dennis Whiting, PA-C b, Murad Alam, MD, MSCI b, c, d,
a Department of Dermatology, Stanford University School of Medicine, Redwood City, California 
b Department of Dermatology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 
c Department of Otolaryngology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 
d Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 

Reprint requests: Murad Alam, MD, MSCI, Department of Dermatology, Northwestern University, 676 N St Clair St, Suite 1600, Chicago, IL 60611.

Abstract

Background

Surgical fires are a rare, but serious complication of dermatologic procedures involving electrosurgical and laser devices. Given the lack of data regarding basic fire safety principles, many dermatologists remain unaware of this potential risk.

Objective

We evaluated the flammability of topical preparations and surgical drapes commonly encountered in the immediate operative field during cutaneous and laser surgery.

Methods

Surgical dressings, drapes, and pork belly skin were examined for fire risk upon exposure to isopropyl alcohol, chlorhexidine gluconate, and aluminum chloride under dry, saturated, and damp conditions. Both electrosurgery and a carbon-dioxide laser were used as ignition sources.

Results

At least some char was observed in 86 of 126 simulated conditions (68%). Flames occurred in 2 test conditions: dry underpad drapes and cotton balls exposed to the carbon-dioxide laser. In general, drapes and dressings dampened or saturated with isopropyl alcohol failed to ignite with electrofulguration or electrodessication, although sparks and moderate char developed on pork belly skin and the underpad drape. Materials dampened or saturated with chlorhexidine gluconate, which contains isopropyl alcohol, generated less smoke and char compared with materials exposed to aluminum chloride, which does not contain alcohol.

Limitations

Future studies may assess the flammability of materials in the setting of oxygen supplementation.

Conclusion

In common cutaneous surgical environments, electrosurgery or ablative laser may lead to char and rarely to fire. Char may be seen in up to two thirds of simulated conditions, and in a minute proportion of conditions, fire is observed.

Le texte complet de cet article est disponible en PDF.

Key words : carbon-dioxide laser, electrosurgery, fire, patient safety, skin preparation, surgical fires


Plan


 Supported by the Department of Dermatology, Northwestern University.
 Conflicts of interest: None declared.


© 2012  American Academy of Dermatology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 67 - N° 4

P. 700-705 - octobre 2012 Retour au numéro
Article précédent Article précédent
  • Topical eflornithine hydrochloride improves the effectiveness of standard laser hair removal for treating pseudofolliculitis barbae: A randomized, double-blinded, placebo-controlled trial
  • Yang Xia, Sunghun Cho, Robin S. Howard, Kurt L. Maggio
| Article suivant Article suivant
  • Cauterization of the germinal nail matrix using phenol applications of differing durations: A histologic study
  • Ricardo Becerro de Bengoa Vallejo, Marta Elena Losa Iglesias, Fermin Viejo Tirado, Rosario Serrano Pardo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.