Zotarolimus-eluting stent versus sirolimus-eluting and paclitaxel-eluting stents for percutaneous coronary intervention: A meta-analysis of randomized trials
Stent actif au zotarolimus versus sirolimus et paclitaxel dans les procédures coronaires percutanées : méta-analyse des essais randomisés
 

Ankur Sethi a, , Amol Bahekar a, Rohit Bhuriya a, Anurag Bajaj b, Param Puneet Singh a, Rohit Arora a, Sandeep Khosla a
a Department of Medicine, Rosalind Franklin University of Medicine and Sciences, 3333, Green Bay Road, North Chicago, IL 60064, USA 
b Department of Medicine, Wright Center of Graduate Medical Education, Scranton, PA, USA 

Corresponding author. Fax: +1 773 257 6726.
Summary
Background

The zotarolimus-eluting stent (ZES) is a new drug-eluting stent that delivers zotarolimus, a synthetic analogue of sirolimus, through a biocompatible phosphorylcholine polymer coating. ZES has shown promising results compared with bare-metal stents, but its safety and efficacy against sirolimus-eluting (SES) and paclitaxel-eluting (PES) stents is yet to be established.

Aims

We aimed to summarize current evidence from randomized trials comparing ZES with SES and PES.

Methods

We searched the Medline, Embase and CENTRAL databases for randomized studies comparing ZES with SES and PES for percutaneous coronary intervention. Relevant clinical and angiographic outcomes were extracted and combined using random and fixed-effect models for heterogeneous and homogenous outcomes, respectively.

Results

Seven randomized trials met the inclusion criteria: ZES group, n =3787; SES group, n =2606; PES group, n =1966. Compared with SES, ZES was associated with significantly higher odds of clinically driven target vessel revascularization (odds ratio [OR] 2.36, 95% confidence interval [CI] 1.78–3.14) and target lesion revascularization (OR 2.46, 95% CI 1.36–4.46). Compared with SES, ZES had higher in-stent restenosis (OR 6.13, 95% CI 3.96–9.50), late lumen loss ‘in-stent’ (mean difference [MD] 0.39mm, 95% CI 0.34–0.44) and late lumen loss ‘in-segment’ (MD 0.18mm, 95% CI 0.15–0.21). ZES was associated with higher in-stent late lumen loss than PES (MD 0.18mm, 95% CI 0.07–0.28). There were no differences in mortality, reinfarction or stent thrombosis with ZES compared with SES and PES.

Conclusion

ZES is not superior to PES and is inferior to SES in terms of angiographic outcomes and clinically driven revascularization.

The full text of this article is available in PDF format.
Résumé
Justification

Le stent actif au zotarolimus est un nouveau stent libérant du zotarolimus, analogue synthétique du sirolimus, au travers d’un polymère biocompatible (phosphorylcholine). Les résultats initiaux sont prometteurs en comparaison des stents métalliques mais l’efficacité et la sécurité, comparativement aux stents au sirolimus ou au paclitaxel, n’ont pas été établies. L’objectif était donc de faire la synthèse des données actuelles des études randomisées comparant ces trois types de stents (zotarolimus, sirolimus et paclitaxel).

Méthode

Nous avons interrogé les bases Medline, Embase et CENTRAL, en nous intéressant aux études randomisées comparant ces différents types de stents pour les interventions coronaires percutanées. Les données cliniques et angiographiques, ainsi que les données évolutives ont été extraites et associées en utilisant des modèles préétablis (randomisés et fixes) pour évaluer les données évolutives en incluant leur caractère homogène ou hétérogène.

Résultats

Sept études randomisées répondaient aux critères d’inclusion incluant 3787 patients dans le groupe zotarolimus, 2606 patients dans le groupe sirolimus et 1966 patients dans le groupe paclitaxel. Le groupe zotarolimus est associé à un taux accru d’efficacité sur la revascularisation du vaisseau site (OR 2,36, IC 95% 1,78–3,14) et de traitement de la lésion cible (OR 2,46, IC 95% 1,36–4,46), comparativement aux stents au sirolimus. Le stent au sirolimus était associé à un taux de resténose intra-stent plus élevé (OR 6,13, IC 95% 3,87–9,50), une réduction de calibre intra-stent (différence moyenne 0,39mm, IC 95% 0,34–0,44) ainsi qu’à la réduction de calibre du segment considéré (différence moyenne 0,18mm, IC 95% 0,15–0,21) comparativement aux stents au sirolimus. Enfin, le stent au zotarolimus est associé avec une réduction de calibre intra-stent plus élevé (différence 0,18mm, IC 95% 0,07–0,28) comparativement au paclitaxel. Il n’y avait pas de différence du taux de réinfarctus ou de thrombose de stent avec le stent au zotarolimus, comparativement aux stents au sirolimus ou au paclitaxel.

Conclusion

Le stent au zotarolimus n’est pas supérieur au stent au paclitaxel et est inférieur en termes d’efficacité sur les critères angiographiques et l’indication à une revascularisation sur les critères cliniques, comparativement au stent au sirolimus.

The full text of this article is available in PDF format.

Keywords : Zotarolimus, Drug-eluting stents, Percutaneous coronary intervention

Mots clés : Zotarolimus, Stent actif, Angioplastie coronaire percutanée

Abbreviations : CI, DES, MACE, OR, PCI, PES, RCT, SES, STEMI, TLR, TVR, ZES


Introduction

The first commercially available drug-eluting stents (DES) – the sirolimus-eluting stent (SES) and the paclitaxel-eluting stent (PES) – significantly reduced rates of restenosis and repeat revascularization after percutaneous coronary intervention (PCI) compared with bare-metal stents, in a wide variety of patients [1]. However, the long-term safety of these stents has been questioned by the reports of increased incidence of stent thrombosis, especially with PES [2, 3]. Arterial wall inflammation, delayed healing and poor endothelialization are some of the factors thought to be responsible for late stent thrombosis events after DES implantation [4, 5].

Zotarolimus is a novel agent with structural homology to sirolimus, developed exclusively for its use in DES. The zotarolimus-eluting stent (ZES) has a low profile, a thin strut design and a biocompatible phosphorylcholine polymer coating (which mimics the red blood cell outer membrane), and it elutes more than 90% of the drug in the first few weeks after implantation [6]. These advances in stent design, polymer and drug elution kinetics are thought to reduce platelet adhesion and improve arterial healing, and may therefore decrease the incidence of stent thrombosis compared with SES and PES. ZES has been found to have better neointimal strut coverage compared with SES, as measured by optical coherence tomography at 9months [7]. Also, a randomized controlled trial (RCT) comparing ZES with a bare-metal stent showed a reduction in the rates of angiographic and clinical restenosis, with no difference in stent thrombosis [8]. Despite early success, the role of ZES compared with SES and PES is unclear. RCTs comparing ZES with SES and PES have shown mixed results. Therefore, we decided to perform a meta-analysis of RCTs comparing ZES with SES and PES for PCI.

Methods
Objective

Our goal was to compare ZES with two established stents used for PCI – SES and PES – in terms of angiographic and clinical endpoints.

Search strategy

We performed a systematic search of the Medline, Cochrane Central Register of Controlled Trials (CENTRAL) and Embase databases for RCTs comparing ZES with SES and/or PES, published before 30 September 2010. The keywords ‘zotarolimus’ and ‘zotarolimus eluting stent’ were used. All retrieved abstracts and/or articles were reviewed for possible inclusion. The references of review articles and included studies were hand-searched for any relevant studies. In addition; the manufacturer’s website (index.htm) was screened for any potentially relevant studies on 30 September 2010. No language restriction was imposed. RCTs comparing ZES with SES and/or PES and reporting angiographic and clinical endpoints were eligible for inclusion. Non-randomized studies or registries; comparisons with stents other than SES or PES and studies reporting no clinical or angiographic endpoints were excluded.

Data extraction and validity assessment

Two investigators (A.S. and A.B.) independently searched the databases for eligible studies. The original manuscripts of potentially relevant studies were reviewed. The study characteristics and endpoints were entered on a prespecified data form. The following study characteristics were extracted: sample size; method of randomization; inclusion and exclusion criteria; mean age; use of angiographic follow-up; primary endpoint; duration of dual antiplatelet therapy; follow-up duration; method of evaluation of angiographic outcomes; and criteria for target vessel or lesion revascularization. Any inconsistencies were reviewed with the help of a third author.

Endpoints

The following clinical endpoints were evaluated: major adverse cardiac events (MACE); mortality; myocardial infarction; target vessel revascularization (TVR); target lesion revascularization (TLR); and stent thromboses. The following angiographic outcomes were evaluated: in-stent and in-segment restenosis; and in-stent and in-segment late lumen loss.

Statistical analysis

A study-level analysis was done. Data were analysed using Review Manager 5 (The Nordic Cochrane Centre, The Cochrane Collaboration, 2008). Odds ratios (ORs) and 95% confidence intervals (CIs) were used as summary statistics for all outcomes except the continuous variables in-stent and in-segment late lumen loss, for which mean differences were calculated. Studies were evaluated for heterogeneity by visual inspection of the CIs and by means of I2 [I2=(Q–df)/Q], where Q is the χ2 statistic and df is degree of freedom. A value of I2>30% was considered as an indicator of significant heterogeneity. A Mantel–Haenszel fixed-effect model was used to calculate the pooled ORs for non-heterogeneous endpoints. Random effect (DerSimonian) analysis was performed in the presence of significant heterogeneity across the studies. A P value<0.05 was considered significant.

Results

Seven RCTs were included in the meta-analysis (Figure 1) [9, 10, 11, 12, 13, 14, 15], resulting in a total of 8359 patients: 3787 patients in the ZES group; 2606 in the SES group; and 1966 in the PES group. The characteristics of included studies are shown in Table 1. Three studies compared ZES with SES, two compared ZES with PES and two compared all three stents. Three studies included patients with elective PCI only, one study included stable angina or acute coronary syndrome but excluded ST-segment elevation myocardial infarction (STEMI), one study included patients with STEMI only and two included all-comers (Table 1). In addition, three studies [10, 11, 13] had specific angiographic criteria for inclusion, as shown in Table 1. The mean age of the study population varied from 57 to 67years. Patients groups were well balanced with regard to the most relevant characteristics within individual studies. All studies except SORT OUT III [15] had routine angiographic follow-up. All studies used the Endeavor stent (Medtronic, Santa Rosa, CA, USA) in the ZES group, except for one study [10], which used the ZoMaxx stent (Abbott Laboratories, Chicago, IL, USA). The definitions of the relevant clinical endpoints used in the included studies are shown in Table 2. Clinical endpoints were adjudicated by an independent committee blinded to stent assignment in all seven studies. Angiographic analysis was done at independent core laboratories blinded to stent assignment in all studies. A 3-year follow-up for the ENDEAVOR III study [16] and 2-year follow-up for the ENDEAVOR IV [17] and ISART-TEST-2 [9] studies were reported subsequently, in addition to the respective 9-month, 12-month and 12-month follow-ups published initially. Also, the SORT OUT III trial reported clinical endpoints at 9months and 18months. The other three studies had a follow-up duration of 1year or less (Table 1). To accommodate the variable follow-up periods, we decided to combine the clinical endpoints at follow-up of up to 1year and at longest available follow-up. No significant disagreement was found between the data retrieved by two investigators.



Figure 1


Figure 1. 

Study selection process.

Zoom

Clinical endpoints
MACE

The definition of MACE used in each study is shown in Table 2. MACE were experienced by 12%, 8.6% and 11.8% of patients randomized to the ZES, SES and PES groups, respectively. There was moderate heterogeneity among the studies for the endpoint of MACE, as evidenced by the I2 in excess of 40% for all four comparisons. Therefore, a random-effect meta-analysis was performed. Compared with SES, ZES was associated with significantly higher MACE up to 1year (OR 1.50, 95% CI 1.06–2.13) and at longest available follow-up (OR 1.39, 95% CI 1.01–1.91). There was no difference in MACE between PES and ZES up to 1year (OR 0.94, 95% CI 0.67–1.32) and at longest available follow-up (OR 0.94, 95% CI 0.68–1.30).

Myocardial infarction

There was no difference in myocardial infarction between ZES versus SES (OR 1.0, 95% CI 0.41–2.45) and ZES versus PES (OR 0.55, 95% CI 0.55–1.04) up to 1year and at longest available follow-up (ZES versus SES: OR 0.83, 95% CI 0.40–1.72; ZES versus PES: OR 0.71, 95% CI 0.48–1.07).

Mortality

There was no difference in mortality between ZES versus SES (OR 1.23, 95% CI 0.80–1.89) and ZES versus PES (OR 1.11, 95% CI 0.59–2.06) up to 1year and at longest available follow-up (ZES versus SES: OR 1.01, 95% CI 0.62–1.65; ZES versus PES: OR 1.20, 95% CI 0.74–1.96).

Clinically driven target vessel and lesion revascularization

All seven studies reported an incidence of clinically or ischaemia-driven TVR and/or TLR, as defined in Table 2. ZES was associated with significantly higher odds of clinically driven TVR compared with SES up to 1year (OR 2.31, 95% CI 1.65–3.22) and at longest available follow-up (OR 2.36, 95% CI 1.78–3.14), as shown in Figure 2A. Similarly, ZES use was associated with significantly higher odds of clinically driven TLR compared with SES up to 1year (OR 2.87, 95% CI 1.89–4.35) and at longest available follow-up (OR 2.46, 95% CI 1.36–4.46), as shown in Figure 2B. There was no difference in clinically driven TVR and TLR between ZES and PES up to 1year (TVR: OR 0.85, 95% CI 0.61–1.18; TLR: OR 0.94, 95% CI 0.71–1.26) and at longest available follow-up (TVR: OR 0.88, 95% CI 0.63–1.23; TLR: OR 1.11, 95% CI 0.58–2.13), as shown in Figure 3A and B.



Figure 2


Figure 2. 

Forest plots comparing the zotarolimus-eluting stent (ZES) with the sirolimus-eluting stent (SES) for the following endpoints: (A) target vessel revascularization; (B) target lesion revascularization; (C) stent thrombosis. CI: confidence interval; M-H: Mantel–Haenszel.

Zoom



Figure 3


Figure 3. 

Forest plots comparing the zotarolimus-eluting stent (ZES) with the paclitaxel-eluting stent (PES) for the following endpoints: (A) target vessel revascularization; (B) target lesion revascularization; (C) stent thrombosis. CI: confidence interval; M-H: Mantel–Haenszel.

Zoom

Stent thromboses

There was no significant difference in stent thromboses between ZES and SES up to 1year (OR 1.53, 95% CI 0.39–5.96) and at longest available follow-up (OR 1.12, 95% CI 0.41–3.08), as shown in Figure 2C. Similarly, there was no difference in stent thromboses between ZES and PES up to 1year (OR 1.05, 95% CI 0.56–2) and at longest available follow-up (OR 0.88, 95% CI 0.51–1.55), as shown in Figure 3C.

Angiographic outcomes

Compared with SES, ZES was associated with a significantly higher rate of in-stent restenosis (OR 6.13, 95% CI 3.96–9.50) and in-segment restenosis (OR 3.46, 95% CI 1.59–7.50), as shown in Figure 4A and B, respectively. There was no difference between ZES and PES in in-stent restenosis (OR 1.56, 95% CI 0.84–2.90) and in-segment restenosis (OR 1.44, 95% CI 0.88–2.35) (Figure 5A and B). Also, compared with SES, ZES was associated with higher in-stent late lumen loss (mean difference 0.39mm, 95% CI 0.34–0.44; Figure 4C) and in-segment late lumen loss (mean difference 0.18mm, 95% CI 0.15–0.21). However, in-segment late lumen loss was similar (mean difference 0.06mm, 95% CI –0.04–0.16) but in-stent lumen loss was higher (mean difference 0.18mm, 95% CI 0.07–0.28) in the ZES group compared with the PES group (Figure 5C).



Figure 4


Figure 4. 

Forest plots comparing the zotarolimus-eluting stent (ZES) with the sirolimus-eluting stent (SES) for: (A) in-stent restenosis; (B) in-segment restenosis; (C) in-segment late lumen loss. CI: confidence interval; M-H: Mantel–Haenszel.

Zoom



Figure 5


Figure 5. 

Forest plots comparing the zotarolimus-eluting stent (ZES) with the paclitaxel-eluting stent (PES) for: (A) in-stent restenosis; (B) in-segment restenosis; (C) in-segment late lumen loss. CI: confidence interval; M-H: Mantel–Haenszel.

Zoom

Discussion

The present meta-analysis found that ZES use was associated with significantly higher revascularization rates compared with SES use. Also, ZES was inferior to SES in terms of the angiographic endpoints of restenosis and late lumen loss. ZES was similar to PES for all clinical and most angiographic endpoints, except in-stent late lumen loss. In addition, no difference in stent thromboses was apparent during follow-up when ZES was compared with SES and PES. To the best of our knowledge, this is the first meta-analysis comparing ZES directly with SES and PES separately. The included studies varied in terms of patient population, ranging from stable coronary artery disease to acute coronary syndrome, STEMI and all-comers, a pattern that represents the state of DES use in contemporary practice (Table 1). We combined these studies to achieve a higher power to evaluate ZES (a relatively new DES), against established DESs (SES and PES), in terms of both clinical and angiographic endpoints.

Zotarolimus is an analogue of sirolimus, which binds to the immunophillin protein FKBP 12 to inhibit a growth-regulating enzyme known as mammalian target of rapamycin (mTOR) [18]. Zotarolimus has a shorter half-life and less affinity for FKBP 12 than sirolimus. In addition, the two ZES evaluated in our analysis – Endeavor (Medtronic, Santa Rosa, CA, USA) and ZoMaxx (Abbott Laboratories, Chicago, IL, USA) – have rapid drug elution kinetics, a clear distinction from currently available SES, which have a slower drug release [18]. These pharmacological differences may explain the relatively weak antiproliferative effect of ZES and consequently higher restenosis compared with SES. On the other hand, ZES was similar to PES with regard to most angiographic endpoints, which is consistent with previous studies [19, 20] that showed a higher incidence of clinical and angiographic stenosis with PES compared with SES. The difference in late lumen loss between SES and ZES was higher than reported previously between SES and PES [20]. As some authors have suggested a curvilinear relationship between late lumen loss and probability of TLR [21], this accentuated late lumen loss may place patients treated with ZES closer to the steeper slope of the curve. Although the ZoMaxx and Endeavor stents have a similar thin strut design, biocompatible phosphorylcholine polymer and zotarolimus concentration (10μg/mm), there are some differences in the stent platforms and drug elution kinetics [18]. Exclusion of the ZoMaxx I study from the meta-analysis did not change the results for any endpoint significantly.

All studies except the SORT OUT III study had a routine angiographic follow-up (Table 1), which raises concern about increased revascularization rates secondary to oculostenotic reflex. All included studies reported clinically or ischaemia-driven revascularization rates. In addition, studies comparing ZES with SES reported explicit indications used for clinically or ischaemia-driven revascularization (Table 2). Although more than 70% stenosis on follow-up angiogram was considered as one of the indication for TLR, but TLR in the ZES group in the SORT OUT III study (6.1%), which had no angiographic follow-up, and in the ENDEAVOR III (6.3%) and ZEST (4.8%) studies, which had planned angiographic follow-up, were not significantly different. On the other hand, TLR in the ISAR-TEST-2 study was higher in both the ZES (14%) and SES (10.7%) groups. All statistical heterogeneity in the analysis for TLR was explained by the ISAR-TEST-2 study; its exclusion reduced I2 from 74% to 0% without loss of statistical significance (OR 3.43, 95% CI 2.36–4.98). Therefore, the impact of routine angiographic follow-up of revascularization rates cannot be clearly determined from our analysis. However, the results of TLR for ZES versus SES were robust, and remain significant on exclusion of one study at a time from the meta-analysis. Also, the odds of in-stent restenosis were lower in the ENDEAVOR III study (4.67), which systematically excluded patients with complex lesions or acute coronary syndrome, than in the SORT OUT III (6.38), ZEST (5.86) and ZEST-AMI (13.66) studies, which included patients with acute coronary syndrome and had no angiographic exclusion criteria (Figure 4). Moreover, both the ZEST and SORT OUT III trials independently found a significant increase in TVR and TLR with ZES use. Therefore, it is possible that clinical and angiographic differences between ZES and SES will become apparent in high-risk patients in the real-world clinical setting.

ZES was designed with the intention of reducing stent thrombosis compared with SES and PES. The cumulative incidence of stent thrombosis in the ENDEAVOR I–IV and PK studies at 5years was about 0.8% (95% CI 0.06–1.54), which is lower than the cumulative incidence of 1% in our meta-analysis, considering the difference in duration of follow-up [21]. This could be due to the inclusion of acute myocardial infarction and complex lesions in the studies [9, 14, 15], which contributed the majority of patients to our analysis, compared with elective PCI for a single angiographically defined lesion in the ENDEAVOR I–IV studies. The incidence of stent thromboses in the SES (0.8%) and PES (1.3%) cohorts in our analysis were similar to those in previous studies [22, 23]. It is important to note that only the ENDEAVOR III [16], ENDEAVOR IV [17] and ISAR-TEST-2 [9] trials reported the incidence of stent thromboses later than 6months after completion of the recommended duration of dual antiplatelet therapy, at follow-up periods of 3years, 2years and 2years, respectively (Table 1). Although there was no difference in very late stent thromboses between ZES and SES in the ENDEAVOR III and ISAR-TEST-2 studies, a trend (P =0.069) towards higher very late stent thromboses with PES compared with ZES was seen in the ENDEAVOR IV trial.

The results of the PROTECT trial – a large randomized-design trial comparing ZES with SES for the primary endpoint of stent thromboses at 3years – recently became available [24]. Considering the magnitude and relevance of this study, we performed an updated analysis. The addition of the PROTECT trial further strengthened our conclusions, as there was no difference in mortality (OR, 1.03, 95% CI 0.75–1.41), myocardial infarction (OR 0.93, 95% CI 0.63–1.38) or stent thrombosis (OR 1.06, 95% CI 0.57–1.97) between ZES and SES. However, ZES was associated with a higher incidence of TVR (OR 1.87, 95% CI 1.13–3.08) and TLR (OR 2.18, 95% CI 1.44–3.31). The forest plots are shown in Appendix A, respectively, in the supplementary appendix.

To decrease the incidence of stent thrombosis while maintaining the benefit of low repeat revascularization is one of the key objectives of current research into stent design and development [25]. As opposed to TLR, the incidence of stent thrombosis is very low in contemporary clinical studies examining the newer stents. Therefore, a very large sample size with a long follow-up period is needed to detect any statistically significant difference compared with established stents. Also, the SES (Cypher; Cordis/Johnson and Johnson, FL, USA), which remains unsurpassed in terms of TLR and restenosis, will be no longer manufactured by the end of 2011. These limitations pose a challenge to the design and conduct of clinical trials evaluating the newer coronary stents.

Study limitations

This was a study-level analysis; patient-level data may improve the accuracy of the results. Owing to the small number of studies in our analysis, no formal test to detect publication bias was done. As long-term follow-up was not available for most studies, no robust conclusion can be drawn about the difference in very late stent thrombosis, particularly after the completion of dual antiplatelet therapy. Also of note, these results are not applicable to the newer generation ZES (Endeavor Resolute), which has a different polymer and drug elution kinetics [17]. A recent observational study with the Resolute ZES found a very low rate of clinical restenosis compared with historical Endeavor ZES data [26].

Conclusion

ZES appears inferior to SES and similar to PES in terms of angiographic outcomes and revascularization rates. Mortality and reinfarction were similar when ZES was compared with SES and PES. Also, no difference in stent thromboses was apparent in studies with follow-up periods ranging from 1 to 3years.

Disclosure of interest

The authors declare that they have no conflicts of interest concerning this article.


Appendix A. Supplementary data



Fig. S1 : 



Fig. S2 : 

References

Kirtane A.J., Gupta A., Iyengar S., and al. Safety and efficacy of drug-eluting and bare metal stents: comprehensive meta-analysis of randomized trials and observational studies Circulation 2009 ;  119 : 3198-3206 [cross-ref]
Bavry A.A., Kumbhani D.J., Helton T.J., and al. Late thrombosis of drug-eluting stents: a meta-analysis of randomized clinical trials Am J Med 2006 ;  119 : 1056-1061 [inter-ref]
Daemen J., Wenaweser P., Tsuchida K., and al. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study Lancet 2007 ;  369 : 667-678 [cross-ref]
Camenzind E., Steg P.G., Wijns W. Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern Circulation 2007 ;  115 : 1440-1455[discussion 55].  [cross-ref]
Finn A.V., Nakazawa G., Joner M., and al. Vascular responses to drug eluting stents: importance of delayed healing Arterioscler Thromb Vasc Biol 2007 ;  27 : 1500-1510 [cross-ref]
Pinto Slottow T.L., Waksman R. Overview of the 2007 Food and Drug Administration Circulatory System Devices Panel meeting on the endeavor zotarolimus-eluting coronary stent Circulation 2008 ;  117 : 1603-1608 [cross-ref]
Kim J.S., Jang I.K., Kim T.H., and al. Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents Heart 2009 ;  95 : 1907-1912 [cross-ref]
Fajadet J., Wijns W., Laarman G.J., and al. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial Circulation 2006 ;  114 : 798-806 [cross-ref]
Byrne R.A., Kastrati A., Tiroch K., and al. 2-year clinical and angiographic outcomes from a randomized trial of polymer-free dual drug-eluting stents versus polymer-based Cypher and Endeavor [corrected] drug-eluting stents J Am Coll Cardiol 2010 ;  55 : 2536-2543 [cross-ref]
Chevalier B., Di Mario C., Neumann F.J., and al. A randomized, controlled, multicenter trial to evaluate the safety and efficacy of zotarolimus- versus paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries The ZoMaxx I trial JACC Cardiovasc Interv 2008 ;  1 : 524-532 [cross-ref]
Kandzari D.E., Leon M.B., Popma J.J., and al. Comparison of zotarolimus-eluting and sirolimus-eluting stents in patients with native coronary artery disease: a randomized controlled trial J Am Coll Cardiol 2006 ;  48 : 2440-2447 [cross-ref]
Lee C.W., Park D.W., Lee S.H., and al. Comparison of the efficacy and safety of zotarolimus-, sirolimus-, and paclitaxel-eluting stents in patients with ST-elevation myocardial infarction Am J Cardiol 2009 ;  104 : 1370-1376 [inter-ref]
Leon M.B., Mauri L., Popma J.J., and al. A randomized comparison of the ENDEAVOR zotarolimus-eluting stent versus the TAXUS paclitaxel-eluting stent in de novo native coronary lesions 12-month outcomes from the ENDEAVOR IV trial J Am Coll Cardiol 2010 ;  55 : 543-554 [cross-ref]
Park D.W., Kim Y.H., Yun S.C., and al. Comparison of zotarolimus-eluting stents with sirolimus- and paclitaxel-eluting stents for coronary revascularization: the ZEST (comparison of the efficacy and safety of zotarolimus-eluting stent with sirolimus-eluting and paclitaxel-eluting stent for coronary lesions) randomized trial J Am Coll Cardiol 2010 ;  56 : 1187-1195 [cross-ref]
Rasmussen K., Maeng M., Kaltoft A., and al. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial Lancet 2010 ;  375 : 1090-1099 [cross-ref]
Eisenstein E.L., Leon M.B., Kandzari D.E., and al. Long-term clinical and economic analysis of the Endeavor zotarolimus-eluting stent versus the cypher sirolimus-eluting stent: 3-year results from the ENDEAVOR III trial (Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) JACC Cardiovasc Interv 2009 ;  2 : 1199-1207 [cross-ref]
Leon M.B., Kandzari D.E., Eisenstein E.L., and al. Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) JACC Cardiovasc Interv 2009 ;  2 : 1208-1218 [cross-ref]
Brugaletta S., Burzotta F., Sabate M. Zotarolimus for the treatment of coronary artery disease: pathophysiology, DES design, clinical evaluation and future perspective Expert Opin Pharmacother 2009 ;  10 : 1047-1058 [cross-ref]
Schomig A., Dibra A., Windecker S., and al. A meta-analysis of 16 randomized trials of sirolimus-eluting stents versus paclitaxel-eluting stents in patients with coronary artery disease J Am Coll Cardiol 2007 ;  50 : 1373-1380 [cross-ref]
Windecker S., Remondino A., Eberli F.R., and al. Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization N Engl J Med 2005 ;  353 : 653-662 [cross-ref]
Pocock S.J., Lansky A.J., Mehran R., and al. Angiographic surrogate end points in drug-eluting stent trials: a systematic evaluation based on individual patient data from 11 randomized, controlled trials J Am Coll Cardiol 2008 ;  51 : 23-32 [cross-ref]
Kaltoft A., Jensen L.O., Maeng M., and al. 2-year clinical outcomes after implantation of sirolimus-eluting, paclitaxel-eluting, and bare-metal coronary stents: results from the WDHR (Western Denmark Heart Registry) J Am Coll Cardiol 2009 ;  53 : 658-664 [cross-ref]
Millauer N., Juni P., Hofmann A., and al. Sirolimus versus paclitaxel coronary stents in clinical practice Catheter Cardiovasc Interv 2011 ;  77 : 5-12 [cross-ref]
Camenzind E., Wijns W., Mauri L., and al. Stent thrombosis and major clinical events at 3years after zotarolimus-eluting or sirolimus-eluting coronary stent implantation: a randomised, multicentre, open-label, controlled trial Lancet 2012 ;  380 (9851) : 1396-1405 [cross-ref]
Garg S., Serruys P.W. Coronary stents: looking forward J Am Coll Cardiol 2010 ;  56 : S43-S78
Yeung A.C., Leon M.B., Jain A., and al. Clinical evaluation of the Resolute zotarolimus-eluting coronary stent system in the treatment of de novo lesions in native coronary arteries: the RESOLUTE US clinical trial J Am Coll Cardiol 2011 ;  57 : 1778-1783 [cross-ref]
Cutlip D.E., Windecker S., Mehran R., Boam A., Cohen D.J., van Es G.A., and al. Clinical end points in coronary stent trials: a case for standardized definitions Circulation 2007 ;  115 : 2344-2351 [cross-ref]
Thygesen K., Alpert J.S., White H.D., and al. Universal definition of myocardial infarction Circulation 2007 ;  116 : 2634-2653 [cross-ref]



© 2012  Elsevier Masson SAS. All Rights Reserved.
EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline