S'abonner

Adenoma detection rate is necessary but insufficient for distinguishing high versus low endoscopist performance - 20/12/12

Doi : 10.1016/j.gie.2012.08.038 
Hank S. Wang, MD, MSHS 1, 2, 4, 5, 7, Joseph Pisegna, MD 1, 2, 5, Rusha Modi, MD 6, Li-Jung Liang, PhD 3, Mary Atia, MD 6, Minh Nguyen, MD 6, Hartley Cohen, MD 1, Gordon Ohning, MD, PhD 1, 2, 5, Martijn van Oijen, PhD 2, 7, Brennan M.R. Spiegel, MD, MSHS 1, 2, 4, 5, 7,
1 Department of Medicine, Division of Gastroenterology, VA Greater Los Angeles Healthcare System, Los Angeles, California, USA 
2 Department of Medicine, Division of Digestive Diseases, David Geffen School of Medicine at UCLA, Los Angeles, California, USA 
3 Division of General Internal Medicine and Health Services Research, David Geffen School of Medicine at UCLA, Los Angeles, California, USA 
4 Department of Health Services, UCLA School of Public Health, Los Angeles, California, USA 
5 CURE Digestive Diseases Research Center, Los Angeles, California, USA 
6 Division of General Internal Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA 
7 UCLA/VA Center for Outcomes Research and Education (CORE), Los Angeles, California, USA 

Reprint requests: Brennan M.R. Spiegel, MD, MSHS, VA Greater Los Angeles Healthcare System, David Geffen School of Medicine at UCLA, UCLA/VA Center for Outcomes Research and Education (CORE), 11301 Wilshire Blvd., Bldg. 115, Room 215, Los Angeles, CA 90073

Résumé

Background

Endoscopist quality is benchmarked by the adenoma detection rate (ADR)—the proportion of cases with 1 or more adenomas removed. However, the ADR rewards the same credit for 1 versus more than 1 adenoma.

Objective

We evaluated whether 2 endoscopist groups could have a similar ADR but detect significantly different total adenomas.

Design

We retrospectively measured the ADR and multiple measures of total adenoma yield, including a metric called ADR-Plus, the mean number of incremental adenomas after the first. We plotted ADR versus ADR-Plus to create 4 adenoma detection patterns: (1) optimal (↑ADR/↑ADR-Plus); (2) one and done (↑ADR/↓ADR-Plus); (3) all or none (↓ADR/↑ADR-Plus); (4) none and done (↓ADR/↓ADR-Plus).

Setting

Tertiary-care teaching hospital and 3 nonteaching facilities servicing the same patient pool.

Patients

A total of 3318 VA patients who underwent screening between 2005 and 2009.

Main Outcome Measurements

ADR, mean total adenomas detected, advanced adenomas detected, ADR-Plus.

Results

The ADR was 28.8% and 25.7% in the teaching (n = 1218) and nonteaching groups (n = 2100), respectively (P = .052). Although ADRs were relatively similar, the teaching site achieved 23.5%, 28.7%, and 29.5% higher mean total adenomas, advanced adenomas, and ADR-Plus versus nonteaching sites (P < .001). By coupling ADR with ADR-Plus, we identified more teaching endoscopists as optimal (57.1% vs 8.3%; P = .02), and more nonteaching endoscopists in the none and done category (42% vs 0%; P = .047).

Limitations

External generalizability, nonrandomized study.

Conclusion

We found minimal ADR differences between the 2 endoscopist groups, but substantial differences in total adenomas; the ADR missed this difference. Coupling the ADR with other total adenoma metrics (eg, ADR-Plus) provides a more comprehensive assessment of adenoma clearance; implementing both would better distinguish high- from low-performing endoscopists.

Le texte complet de cet article est disponible en PDF.

Abbreviations : ADR, WLAVA, CRC


Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication. This research was supported by a Veterans Affairs Merit Award (IIR 08-310) to Dr Spiegel and an NIH training grant (T32DK07180-34) to Dr Wang.
 See CME section; p. 108.
 The opinions and assertions contained herein are the sole views of the authors and are not to be construed as official or as reflecting the views of the Department of Veteran Affairs.


© 2013  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 77 - N° 1

P. 71-78 - janvier 2013 Retour au numéro
Article précédent Article précédent
  • Diagnostic and therapeutic yield is not influenced by the timing of small-bowel enteroscopy: morning versus afternoon
  • Madhusudhan R. Sanaka, Udayakumar Navaneethan, Bennie R. Upchurch, Rocio Lopez, Sabrina Vannoy, Milan Dodig, Janice M. Santisi, John J. Vargo
| Article suivant Article suivant
  • Carbon dioxide insufflation does not reduce pain scores during colonoscope insertion in unsedated patients: a randomized, controlled trial
  • Peng-Jen Chen, Chung-Hsien Li, Tien-Yu Huang, Yu-Lueng Shih, Heng-Cheng Chu, Wei-Kuo Chang, Tsai-Yuan Hsieh

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.