S'abonner

The usefulness of computer-aided joint space analysis in the assessment of rheumatoid arthritis - 16/07/13

Doi : 10.1016/j.jbspin.2012.10.022 
Alexander Pfeil a, , Diane M. Renz b, Andreas Hansch d, Franz Kainberger c, Gabriele Lehmann a, Ansgar Malich e, Gunter Wolf a, Joachim Böttcher f
a Department of Internal Medicine III, Jena University Hospital, Friedrich Schiller University Jena, Erlanger Allee 101, 07747 Jena, Germany 
b Department of Diagnostic Radiology, Charité University Medicine Berlin, Campus Virchow Clinic, Augustenburger Platz 1, 13353 Berlin, Germany 
c Department of Diagnostic Radiology, Medical University of Vienna, AKH, Waehringer Guertel 18-20, 1090 Vienna, Austria 
d Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University, Erlanger Allee 101, 07747 Jena, Germany 
e Department of Radiology, Suedharz Clinic Nordhausen, Dr. Robert-Koch Street 39, 99734 Nordhausen, Germany 
f Institute of Diagnostic and Interventional Radiology, SRH Wald-Klinikum Gera, Straße des Friedens 122, 07548 Gera, Germany 

Corresponding author. Tel.: +49 3641 9324384; fax: +49 3641 9324302.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 2
Vidéos 0
Autres 0

Abstract

Objective

Computer-aided joint space analysis (CAJSA) is a newly developed technique for the measurement of radiogeometrically detectable joint space widths of the metacarpal-phalangeal (JSD-MCP) and proximal-interphalangeal articulations (JSD-PIP). The aim of this study was to verify the sensitivity and specificity of these CAJSA measurements in the assessment of established RA.

Methods

Four hundred and fifty-eight participants (248 healthy subjects, 210 RA patients) underwent computerized semi-automated measurements of the JSD-MCP and JSD-PIP articulations (CAJSA, Radiogrammetry Kit, Version 1.3.6) based on digitally performed radiographs. The Sharp joint space narrowing score was also performed to determine RA-related joint space narrowing.

Results

The significant severity-dependent reduction for JSD-MCP was –44.0% and for JSD-PIP, –25.94% between Sharp scores 0 and 3. The sensitivity and specificity of JSD-MCP (total) was 88.1% versus 77.8%, respectively (AUC=0.920; P<0.001). Furthermore, JSD-PIP (total) revealed a lower sensitivity and specificity with 61.4% and 88.7% (AUC=0.878; P<0.001).

Conclusion

The CAJSA method presented a reliable assessment of disease-related joint space narrowing in patients suffering from RA with excellent sensitivity and specificity. By providing quantitative data, other scoring methods could be significantly improved, and thereby the accuracy of the diagnosis and a better therapeutic evaluation could be achieved.

Le texte complet de cet article est disponible en PDF.

Keywords : Computer-aided diagnosis, Computer-aided joint space analysis, Joint space width, Finger, Rheumatoid arthritis, Sharp score

Abbreviations : AUC, CAD, CAJSA, CV, JSD, JSD-MCP, JSD-PIP, MCP, PIP, RA, SD


Plan


© 2012  Société française de rhumatologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 80 - N° 4

P. 380-385 - juillet 2013 Retour au numéro
Article précédent Article précédent
  • Therapeutic immunomodulation in systemic vasculitis: Taking stock
  • Xavier Puéchal, Loïc Guillevin
| Article suivant Article suivant
  • Meta-analysis of clinical and radiological efficacy of biologics in rheumatoid arthritis patients naive or inadequately responsive to methotrexate
  • Audrey Pierreisnard, Nahema Issa, Thomas Barnetche, Christophe Richez, Thierry Schaeverbeke

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.