Mitral paravalvular leak detected by three-dimensional transoesophageal echocardiography
Fuite paraprothétique mitrale détectée par échocardiographie transœsophagienne 3D
 

Martina Sordi a, Eric Brochet a, David Messika-Zeitoun a, b,
a Department of Cardiology, Bichat Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France 
b Inserm U698, University Paris 7, Paris, France 

Corresponding author. AP–HP, Cardiology Department, Bichat Hospital, 46, rue Henri-Huchard, 75018 Paris, France. Fax: +1 40 25 67 32.

Keywords : Prosthesis, Paravalvular leak, Three-dimensional echocardiography

Mots clés : Prothèse, Fuite paravalvulaire, Échocardiographie 3D

Abbreviations : 2D, 3D, TEE


A 64-year-old man was admitted to our department because of recent onset of weakness and shortness of breath. He had undergone a surgical mitral commissurotomy in 1977 and a bioprosthetic mitral replacement in 2004. The clinical presentation demonstrated normal blood pressure, no signs of congestive heart failure, no fever and a 3/6 systolic mitral murmur; he was in permanent atrial fibrillation.

Transthoracic echocardiography showed severe left atrial enlargement and the presence of a paravalvular leak. Two-dimensional (2D) transoesophageal echocardiography (TEE) clearly demonstrated severe paravalvular regurgitation (Figure 1A) but real-time three-dimensional (3D) TEE allowed precise location of the paravalvular regurgitant jet at the inferomedial part of the annulus, slightly distant from the prosthetic ring, with a circular and expansive shape (Figure 1B). On colour-flow Doppler imaging, the area of dehiscence was estimated as being close to 0.7cm2 (Figure 1C and D). Owing to the high risk of a third surgical procedure, the absence of signs of congestive heart failure or haemolysis and the requirement of only a minor dose of diuretics, the patient was discharged with a scheduled visit at 1 month.



Figure 1


Figure 1. 

A. 2D TEE showing the severe paravalvular regurgitation. B and C. Real-time 3D TEE allowing precise location of the paravalvular regurgitant jet. D. Planimetry of the area of dehiscence (0.7cm2).

Zoom

Real-time 3D-TEE imaging is a useful echocardiographic modality for the localization and quantification of paravalvular leak. It can provide an en face view of the mitral prosthesis, allowing accurate determination of the location and number of paravalvular dehiscences and is crucial during percutaneous intervention. In the present case, the diagnosis was already obvious in 2D TEE but 3D TEE provided nice simple and intuitive visualization of the leak.

Disclosure of interest

The authors declare that they have no conflicts of interest concerning this article.


Appendix B. Supplementary data

(393 Ko)
  
  
(158 Ko)
  


© 2013  Elsevier Masson SAS. All Rights Reserved.
EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline
You can move this window by clicking on the headline