S'abonner

The Pattern and Distribution of Retinal Breaks in Eyes With Rhegmatogenous Retinal Detachment - 11/12/13

Doi : 10.1016/j.ajo.2013.09.011 
Manoharan Shunmugam a, Anish N. Shah b, Pirro G. Hysi c, Tom H. Williamson a,
a Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom 
b Department of Ophthalmology, King's College Hospital, London, United Kingdom 
c Department of Genetic Epidemiology, King's College London, London United Kingdom 

Inquiries to Tom H. Williamson, Eye Clinic, St. Thomas' Hospital, London SE1 7EH, United Kingdom

Abstract

Purpose

To identify which presenting features of rhegmatogenous retinal detachment (RRD) suggest the presence of multiple retinal breaks and to ascertain relevant patterns in retinal break location.

Design

Observational single-center case series.

Methods

We collected data from 851 eyes undergoing surgery for RRD between January 2001 and September 2011. Data recorded included patient demographics; extent of RRD; and the size, location, and number of retinal breaks. Statistical regression was used to identify risk factors for the presence of multiple breaks and to analyze patterns in break location.

Results

Of 851 patients, 7 patients were excluded because of insufficient data. Of 844 patients analyzed, 60% were male. The mean age was 62 years. Three hundred twenty-eight eyes (38.9%) had solitary breaks, whereas 58.8% had breaks in more than 1 quadrant. The superotemporal (ST) quadrant was involved most frequently (582 eyes; 69%). The superonasal and inferotemporal quadrants were involved in 341 (40%) and 274 (32%) eyes, respectively. The inferonasal (IN) quadrant was involved the least frequently (144 eyes; 17%). Of 328 eyes with only 1 break, it was most likely to be in the ST quadrant (182 eyes; 55%) and least likely to be in the IN quadrant (19 eyes; 6%). The risk of having multiple breaks was highest for patients with inferior breaks. Eyes with an IN quadrant break were almost twice as likely to harbor further breaks compared with eyes with an ST quadrant break. Vitreous hemorrhage at presentation was associated with larger breaks. ST quadrant breaks were most likely to be detached (92%), whereas IN quadrant breaks were least likely to be detached (60%).

Conclusions

The ST quadrant is the most likely location for retinal breaks, the most frequently involved quadrant in eyes with solitary breaks, and has the highest proportion of detached breaks. By contrast, the IN quadrant is the least likely location for a break, the least frequently involved quadrant in eyes with solitary breaks, and the most likely location for attached breaks. The presence of an inferior (especially IN quadrant) retinal break should raise suspicion that the eye harbors further breaks.

Le texte complet de cet article est disponible en PDF.

Plan


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 157 - N° 1

P. 221 - janvier 2014 Retour au numéro
Article précédent Article précédent
  • Metamorphopsia and Optical Coherence Tomography Findings After Rhegmatogenous Retinal Detachment Surgery
  • Fumiki Okamoto, Yoshimi Sugiura, Yoshifumi Okamoto, Takahiro Hiraoka, Tetsuro Oshika
| Article suivant Article suivant
  • Parallelism as a Novel Marker for Structural Integrity of Retinal Layers in Optical Coherence Tomographic Images in Eyes With Epiretinal Membrane
  • Akihito Uji, Tomoaki Murakami, Noriyuki Unoki, Ken Ogino, Kazuaki Nishijima, Shin Yoshitake, Yoko Dodo, Nagahisa Yoshimura

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.