S'abonner

Tomodensitométrie thoracique chez l’enfant : un examen utile mais irradiant - 25/02/14

Doi : 10.1016/j.arcped.2013.12.021 
C. Mordacq a, , A. Deschildre a, L. Petyt b, T. Santangelo c, C. Delvart a, C. Doan d, C. Thumerelle a
a Service de pneumologie et allergologie pédiatriques, hôpital Jeanne-de-Flandre, CHRU de Lille, avenue Eugène-Avinée, 59037 Lille cedex, France 
b Service de radiologie pédiatrique, hôpital Jeanne-de-Flandre, CHRU de Lille, avenue Eugène-Avinée, 59037 Lille cedex, France 
c Service de radiologie thoracique, hôpital Calmette, CHRU de Lille, boulevard du Pr-Leclercq, 59037 Lille cedex, France 
d Service de pédiatrie, hôpital Victor-Provo, 37, rue de Barbieu, 59056 Roubaix, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 3
Vidéos 0
Autres 0

Résumé

Le recours à la tomodensitométrie (TDM) thoracique augmente en pédiatrie. L’objectif de notre travail était double : évaluer ses indications et son impact en pneumologie pédiatrique, et apprécier l’irradiation induite selon la sensibilisation des radiologues à la radioprotection.

Patients et méthodes

Il s’est agi d’une observationnelle, prospective réalisée entre novembre 2009 et avril 2010. Tous les enfants, dont la TDM thoracique avait été présentée en réunion de radio-pneumologie pédiatrique du centre hospitalier régional universitaire (CHRU) de Lille, ont été inclus. Nous avons relevé les caractéristiques démographiques, les indications, l’irradiation (produit dose longueur [PDL] et dose efficace [DE]) et les résultats. Le PDL et la DE ont été comparés selon le lieu de réalisation (TDM double source ou 64 barrettes du CHRU, ou extérieur).

Résultats

Cent trente-cinq patients ont été inclus (âge moyen 6,4ans). Les TDM diagnostiques (61 %), avaient eu un impact diagnostique pour 48 % et thérapeutique direct pour 24 %. Celles de suivi de maladies chroniques (39 %) avaient eu un impact diagnostique pour 38 % et thérapeutique pour 19 %. L’irradiation avait été significativement inférieure pour les TDM réalisées au CHRU, a fortiori avec la TDM 128 barrettes (DE double source : 0,61mSv±0,32 ; DE 64 barrettes : 1,24mSv±0,97 ; DE extérieurs : 2,56mSv±1,98).

Conclusion

La facilité d’accès aux TDM et leur qualité, y compris chez les jeunes enfants, ont augmenté leurs indications, ne dispensant pas de certaines précautions. Notre étude montre que la sensibilisation des radiologues aux risques pédiatriques, les progrès techniques et la collaboration avec les cliniciens réduisent l’irradiation induite.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

New multidetector row computed tomography (CT) has made the imaging of younger children more feasible and extending CT indications to a wide range of pediatric respiratory diseases in the last few years. However, CT is a source of radiation exposure. The aim of this study was to evaluate the main indications and the contribution of chest CT in pediatric pulmonology as well as induced radiation.

Methods

This was an observational, prospective study. Children whose chest CTs were analyzed during multidisciplinary meetings (radiologist, pulmonary pediatrician) were included from November 2009 to April 2010. We collected demographic data, CT results, contribution of CT to diagnosis and management, and radiation doses (dose-length product [DLP] and effective dose). Radiation doses were compared according to the CT scans (Lille University Hospital with 128-slice dual-source CT or Lille University Hospital single-source 64-slice CT, or CT performed outside the university hospital).

Results

One hundred thirty-five patients were included. The mean age was 6.4 years old. The main indications were analysis of bronchial disease (44%), infectious disease (16%), interstitial disease (14%), or a malformation (9%). The aim of CT was diagnosis (61%) or follow-up of previous lung diseases (39%). Diagnosis chest-CT directly contributed to diagnosis in 48% of cases and to treatment in 24%. Follow-up CT contributed to diagnosis in 38% and treatment in 19% of cases. DLP and effective doses were significantly lower for CT performed in the university hospital, especially with the 128-slice CT compared to the others (P<0.001). The effective doses were: 128-slice CT, 0.61mSv±0.32; 64-slice CT, 1.24mSv±0.97; outside university hospital, 2.56mSv±1.98.

Conclusion

This study confirms the role played by chest CT in children, which contributes to diagnosis and management of lung diseases. The main concern of CT application, especially in children, is the radiation burden. Children are more susceptible to the effects of radiation than adults and have a longer life expectancy to develop complications. Both radiologists and pediatricians should be aware of a potential risk and have to conjugate their efforts in reducing this risk. The wide range of radiation doses in this study for the same CT procedures underlines the extensive efforts still needed to limit radiation exposure in children.

Le texte complet de cet article est disponible en PDF.

Plan


© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 21 - N° 3

P. 279-286 - mars 2014 Retour au numéro
Article précédent Article précédent
  • Unité de surveillance continue pédiatrique en centre hospitalier général : l’expérience récente de l’hôpital de Polynésie française
  • H. Gatti, S. Dauger, J. Sommet, C. Chenel, J. Naudin
| Article suivant Article suivant
  • Candidose rénale chez le nouveau-né : à propos d’une observation
  • S. Ben Ameur, Y. Hentati, M. Ben Dhaoui, M. Weli, T. Kamoun, Z. Mnif, R. Mhiri, M. Hachicha

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.