S'abonner

The Corneal Ulcer One-Touch Study: A Simplified Microbiological Specimen Collection Method - 06/12/14

Doi : 10.1016/j.ajo.2014.09.021 
Kaivon Pakzad-Vaezi a, Steve D. Levasseur a, Steven Schendel a, Sean Mark b, Richard Mathias b, Diane Roscoe c, Simon P. Holland a,
a Department of Ophthalmology and Visual Sciences, University of British Columbia, Vancouver, Canada 
b School of Population and Public Health, University of British Columbia, Vancouver, Canada 
c Division of Medical Microbiology and Infection Control, Vancouver General Hospital and Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada 

Inquiries to Simon P. Holland, Section G, 2550 Willow Street, Vancouver, BC V5Z 3N9, Canada

Abstract

Purpose

To determine if a new, single-sample device (ESwab; Copan Diagnostics, Inc) can simplify the traditional multi-sample approach to specimen collection in infectious keratitis.

Design

Prospective, diagnostic test evaluation.

Methods

In this institutional study, patients with suspected infectious keratitis meeting traditional criteria for diagnostic corneal specimen collection and culture were randomized to the order of first specimen collection method: ESwab or a sample directly plated for growth on chocolate agar. This was followed by standard samples for blood agar, Gram stain, Sabouraud agar, thioglycolate broth, and brain heart infusion broth in all cases. The specimens collected using the 2 approaches were analyzed separately by the laboratory in a masked fashion. The main outcome measure was positive growth on cultured media.

Results

Eighty-one eyes from 80 consecutive patients were sampled. Culture positivity rate for the multi-sample method and ESwab was 70% and 69%, respectively, with a 75% agreement rate. ESwab sensitivity was 84% (95% confidence interval [CI]: 72%–93%), with a specificity of 67% (95% CI: 45%–84%). Positive and negative predictive values of the ESwab were 86% (95% CI: 74%–94%) and 64% (95% CI: 43%–82%), respectively. There was no difference in positive culture reports with respect to the order of specimen collection technique used.

Conclusions

The single-sample ESwab method is a more accessible and less cumbersome approach to corneal culturing for ophthalmologists, particularly those in the community setting who do not have access to the full set of traditional culture materials. Culture results using this single-sample approach were comparable to the multi-sample method.

Le texte complet de cet article est disponible en PDF.

Plan


© 2015  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 159 - N° 1

P. 37 - janvier 2015 Retour au numéro
Article précédent Article précédent
  • Association of Open-Angle Glaucoma Loci With Incident Glaucoma in the Blue Mountains Eye Study
  • Kathryn P. Burdon, Paul Mitchell, Anne Lee, Paul R. Healey, Andrew J.R. White, Elena Rochtchina, Peter B.M. Thomas, Jie Jin Wang, Jamie E. Craig
| Article suivant Article suivant
  • Choroidal Findings in Dome-Shaped Macula in Highly Myopic Eyes: A Longitudinal Study
  • Francesco Viola, Laura Dell’Arti, Eleonora Benatti, Alessandro Invernizzi, Chiara Mapelli, Fabio Ferrari, Roberto Ratiglia, Giovanni Staurenghi, Giulio Barteselli

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.