Article

1 Iconography
Access to the text (HTML) Access to the text (HTML)
PDF Access to the PDF text
Service d'aide à la décision clinique
Advertising


Access to the full text of this article requires a subscription.
  • If you are a subscriber, please sign in 'My Account' at the top right of the screen.

  • If you want to subscribe to this journal, see our rates

  • You can purchase this item in Pay Per ViewPay per View - FAQ : 30,00 € Taxes included to order
    Pages Iconography Videos Other
    5 1 0 0


Gynécologie Obstétrique & Fertilité
Volume 43, n° 2
pages 123-127 (février 2015)
Doi : 10.1016/j.gyobfe.2014.12.004
Received : 4 August 2014 ; 
Peut-on réaliser une extraction par ventouse obstétricale en cas de fœtus en présentation du siège décomplété ?
Assessment of vacuum-assisted vaginal delivery in a frank breech presentation
 

G. Bleu a, , P. Deruelle a, b, J. Demetz a, S. Michel c, P. Dufour a, S. Depret a, D. Subtil a, d
a Pôle femme–mère–nouveau-né, hôpital Jeanne-de-Flandre, université Lille Nord de France, 1, rue Eugène-Avinée, 59037 Lille cedex, France 
b EA 4489, IMPRT, faculté de médecine Henri-Warembourg, université Lille Nord de France, 59000 Lille, France 
c Maternité Paul-Gellé, 91, avenue Julien-Lagache, 59100 Roubaix, France 
d EA 2694, université Lille Nord de France, 59000 Lille, France 

Auteur correspondant.
Résumé
Objectifs

Après vérification des critères d’acceptabilité et en présence d’un obstétricien connaissant les manœuvres spécifiques à appliquer, l’accouchement en présentation du siège est possible par voie basse. En cas de difficulté précoce au dégagement, l’application d’une ventouse obstétricale est théoriquement possible mais cette manœuvre est à la fois peu réalisée et peu évaluée. Le but de cette étude est d’évaluer rétrospectivement notre pratique de la ventouse obstétricale sur 6 fœtus en siège décomplété.

Patientes et méthodes

Étude rétrospective comparative des tentatives d’accouchement par voie basse des fœtus en présentation du siège après 37 SA, selon qu’elles ont fait appel ou non à la réalisation d’une ventouse obstétricale.

Résultats

Pendant une période de deux ans, 83 patientes ont débuté les efforts expulsifs avec un fœtus unique à terme en présentation du siège. Pour six d’entre elles, une ventouse a été appliquée sur le siège fœtal (7,2 %). Le taux d’échecs de voie basse était significativement plus élevé dans le groupe « ventouse » que dans le groupe « sans ventouse » (33,3 % versus 6,5 % ; p <0,05). De plus, le pH à la naissance était en moyenne significativement plus bas dans le groupe « ventouse » (7,12±0,11 versus 7,20±0,08 ; p <0,05) et les nouveau-nés de ce groupe présentaient plus fréquemment des lésions cutanées profondes (66,7 % versus 26,0 % ; p <0,05) : en outre, l’un d’entre eux présentait des lésions sévères.

Discussion et conclusion

En cas de présentation du siège, la tentative d’extraction par ventouse obstétricale est liée à un excès de morbidité fœtale.

The full text of this article is available in PDF format.
Abstract
Objectives

After verification of the eligibility criteria and with an obstetrician familiar with the specific maneuvers likely to be needed, vaginal delivery of breech presentations is possible. If problems arise during the active pushing phase of labor, vacuum extraction has been described in the literature for this uncommon condition with limited series. The aim of this study is to assess retrospectively vacuum extraction in frank breech presentation in our center.

Patients and methods

This retrospective study of trials of vaginal delivery of fetuses in breech presentation at term compares cases according to whether they did or did not use a vacuum extraction.

Results

During a two-year period, 83 patients, whom had trials of vaginal delivery in breech presentations, reached the active pushing/bearing down stage after complete cervical dilatation. Vacuum assistance was applied in six of these (7.2 %). The failure rate for vaginal delivery was significantly higher in the group with compared to without vacuum extraction (33.3 % versus 6.5 %, P <0.05). Moreover, the mean pH at birth was significantly lower in the group with vacuum extraction (7.12±0.11 versus 7.20±0.08, P <0.05), and these infants more frequently had deep cutaneous injuries (66.7 % versus 26.0 %, P <0.05).

Discussion and conclusion

In fetuses in breech presentation, when vaginal delivery failed, it seems to be safer for the fetuses to perform caesarean section rather than attempt vacuum extraction.

The full text of this article is available in PDF format.

Mots clés : Siège, Ventouse obstétricale, Complications, Accouchement, Voie basse

Keywords : Breech presentation, Vacuum extractor, Complications, Vaginal delivery




© 2015  Elsevier Masson SAS. All Rights Reserved.
EM-CONSULTE.COM is registrered at the CNIL, déclaration n° 1286925.
As per the Law relating to information storage and personal integrity, you have the right to oppose (art 26 of that law), access (art 34 of that law) and rectify (art 36 of that law) your personal data. You may thus request that your data, should it be inaccurate, incomplete, unclear, outdated, not be used or stored, be corrected, clarified, updated or deleted.
Personal information regarding our website's visitors, including their identity, is confidential.
The owners of this website hereby guarantee to respect the legal confidentiality conditions, applicable in France, and not to disclose this data to third parties.
Close
Article Outline