S'abonner

Évaluation de l’exposition aux radiations du chirurgien lors d’un TLIF mini-invasif : comparaison entre fluoroscopie et navigation O-arm - 04/08/15

Assessment of the surgeon radiation exposure during a minimally invasive TLIF: Comparison between fluoroscopy and O-arm system

Doi : 10.1016/j.neuchi.2015.04.002 
M. Grelat a, , F. Zairi b , M. Quidet b , P. Marinho b , M. Allaoui b , R. Assaker b
a Service de neurochirurgie, Bocage Central, CHRU de Dijon, 14, rue Paul-Gaffarel, 21000 Dijon, France 
b Service de neurochirurgie, hôpital Roger-Salengro, CHRU de Lille, rue Émile-Laine, 59037 Lille, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 2
Vidéos 0
Autres 0

Résumé

Introduction

L’arthrodèse lombaire transforaminale par voie minimale invasive (TLIF MIS) est devenue une technique très populaire dans la prise en charge de nombreuses pathologies dégénératives du rachis lombaire, car elle permet une diminution de l’iatrogénie musculaire. Toutefois, les contrôles radiologiques itératifs inhérents à cette technique sont responsables d’une augmentation significative de l’exposition aux radiations ionisantes pour le chirurgien. Les nouvelles techniques de navigations O-arm permettraient de palier à cet inconvénient, mais ceci reste à démontrer.

Objectifs

Mesurer l’irradiation reçue par le chirurgien au cours d’un TLIF MIS sous fluoroscopie et sous navigation O-arm.

Matériels et méthodes

Cette étude prospective fut menée au CHU de Lille de février à mai 2013. Douze patients ont bénéficié d’un TLIF MIS pour le traitement d’un spondylolisthésis de bas grade. Le guidage fluoroscopique a été utilisé pour 6 patients (groupe 1) et la navigation O-arm pour 6 patients (groupe 2). Des dosimètres passifs (bagues et lunettes) et des dosimètres actifs pour le thorax ont été utilisés afin de mesurer l’exposition du chirurgien aux radiations.

Résultats

La durée moyenne de radioscopie était de 3,718minutes (3,13–4,56) dans le groupe 1, alors qu’aucun cliché de radioscopie n’a été réalisé dans le groupe 2. Dans le groupe 1, la dose d’exposition moyenne était de 12μSv (5–20μSv) sur le thorax, de 1168μSv (510–2790μSv) sur la main dominante et de 179μSv (103–486μSv) sur le cristallin. Dans le groupe 2, la dose d’exposition mesurée a été nulle.

Conclusion

Les doses maximales recommandées peuvent être atteintes, principalement pour le cristallin. Outre les mesures de radioprotection, les systèmes de navigation (O-arm) représentent des alternatives sûres permettant de réduire de manière significative l’exposition du chirurgien.

Le texte complet de cet article est disponible en PDF.

Abstract

Introduction

Transforaminal lumbar interbody fusion with a minimally invasive approach (MIS TLIF) has become a very popular technique in the treatment of degenerative diseases of the lumbar spine, as it allows a decrease in muscle iatrogenic. However, iterative radiological controls inherent to this technique are responsible for a significant increase in exposure to ionizing radiation for the surgeon. New techniques for radiological guidance (O-arm navigation-assisted) would overcome this drawback, but this remains unproven.

Objectives

To analyze the exposure of the surgeon to intraoperative X-ray during a MIS TLIF under fluoroscopy and under O-arm navigation-assisted.

Materials and methods

This prospective study was conducted at the University Hospital of Lille from February to May 2013. Twelve patients underwent a MIS TLIF for the treatment of low-grade spondylolisthesis; six under standard fluoroscopy (group 1) and six under O-arm system (group 2). Passive dosimeters (rings and glasses) and active dosimeters for thorax were used to measure the radiation exposure of the surgeon.

Results

For group 1, the average time of fluoroscopy was 3.718minutes (3.13–4.56) while no radioscopy was perform on group 2. For the first group, the average exposure dose was 12μSv (5–20μSv) on the thorax, 1168μSv (510–2790μSv) on the main hand and 179μSv (103–486μSv) on the lens. The exposure dose was measured zero on the second group.

Conclusion

The maximum recommended doses can be reached, mainly for the lens. In addition to the radioprotection measures, O-arm navigation systems are safe alternatives to significantly reduce surgeon exposure.

Le texte complet de cet article est disponible en PDF.

Mots clés : Arthrodèse lombaire transforaminale, Chirurgie du rachis minimale invasive, Exposition aux rayonnements, Fluoroscopie peropératoire, Neuronavigation O-arm peropératoire, Sûreté radiologique

Keywords : Transforaminal lumbar interbody fusion, Minimally invasive surgery, Radiation exposure, Intraoperative fluoroscopy, Intraoperative O-arm navigation-assisted, Radiation safety


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61 - N° 4

P. 255-259 - août 2015 Retour au numéro
Article précédent Article précédent
  • The cephaloceles: A clinical, epidemiological and therapeutic study of 50 cases
  • A. Kabré, D.S. Zabsonre, A. Sanou, Y. Bako
| Article suivant Article suivant
  • Arthrodèse circonférentielle par voie mini-invasive dans la prise en charge des lésions rachidiennes thoracolombaires cyphosantes : note technique
  • G. Armagagnian, E. Peltier, T. Graillon, T. Adetchessi, B. Blondel, S. Fuentes

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.