Suscribirse

Small diameter metal-on-metal total hip arthroplasty at 13 years – a follow-up study - 08/12/15

Doi : 10.1016/j.otsr.2015.09.031 
N. Tardy , A. Maqdes, P. Boisrenoult, P. Beaufils, P. Oger
 Service d’orthopédie-traumatologie, centre hospitalier Versailles – André-Mignot, 177, rue de Versailles, 78150 Le Chesnay, France 

Corresponding author. Tel.: +33 6 87 55 21 19; fax: +33 1 39 63 87 38.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Theoretically, the properties of second-generation metal-on-metal (MoM) bearings are better for wear, osteolysis and longevity. However, follow-up studies of more than 10 years are rare, in particular with hybrid fixation (cemented stainless steel stems and cementless cup), therefore we evaluated the results of this combination after a mean follow-up of 12.8 years: (1) to analyze the survival rate, (2) to compare it with the survival rate in the same series after 6.4 years (95.8% cup, 94.8% stem), (3) to evaluate clinical and radiographic outcome and (4) to analyze these failures.

Hypothesis

The number of revisions would increase after 10 years.

Materials and methods

We evaluated 106 total hip arthroplasties (THA) (Cedior™ press-fit cup with cemented Acora™ (n=50) and Exafit™ (n=56) stems and 28mm Metasul™ bearings performed between January 1999 and December 2002. The survival rate was calculated by the Kaplan-Meier method. The clinical assessment included the Postel Merle d’Aubigné (PMA) and Oxford scores. The radiographic assessment evaluated radiolucencies and osteolysis on standard X-rays. A histological analysis was only performed during revision THA.

Results

After a mean 12.8 years of follow-up (10–16), 53 THA were reviewed in 48 patients. Thirteen THA revisions (14%) were performed including 11 aseptic revisions (5 stem fractures, 2 cases of impingement and 3 loosenings [1 bipolar and 3 cups] and one case of osteolysis). Overall survival, taking into account revision for aseptic loosening, was 87.6% (CI 95%=77.3 to 99.3%). The mean PMA and Oxford scores at the final follow-up were 17.6±0.8 points (16–18) and 16.5±5.2 points (12–38) respectively. The radiological follow-up mainly identified radiolucencies around the stem in Gruen zones 1 and 7 (17 and 21% respectively).

Discussion

The survival rate of hybrid MoM THA in this series decreased after 10 years and is lower than studies evaluating cementless THA with the 28-mm Metasul™ bearings (90.9 to 100% survival). Although the clinical results are satisfactory, survival is lower. However, the role of MoM bearings is relative in these failures, in particular because trunnionoses (stainless steel stem with 28-mm head), impingement and especially 5-stem fractures were the main causes of failure.

Level of evidence

IV: retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasties, Metal-on-metal bearings


Esquema


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 8

P. 929-936 - décembre 2015 Regresar al número
Artículo precedente Artículo precedente
  • Can cemented dual-mobility cups be used without a reinforcement device in cases of mild acetabular bone stock alteration in total hip arthroplasty?
  • T.X. Haen, G. Lonjon, E. Vandenbussche
| Artículo siguiente Artículo siguiente
  • Poor reproducibility of the MRI measurement of distal femoral torsion
  • M. Ollivier, C. Stelzlen, P. Boisrenoult, N. Pujol, P. Beaufils

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.