Poor reproducibility of the MRI measurement of distal femoral torsion - 08/12/15

Doi : 10.1016/j.otsr.2015.09.028 
M. Ollivier a, b, , C. Stelzlen a, P. Boisrenoult a, N. Pujol a, P. Beaufils a
a Département de chirurgie orthopédique, centre hospitalier de Versailles, 78150 Le Chesnay, France 
b Aix-Marseille université, CNRS, ISM UMR 7287, 13284 Marseille, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Recent publications on patient-specific instrumentation for total knee arthroplasty have reported considerable variability in the axial positioning of the cutting guides for the femoral component. These personalized cutting guides are manufactured based on bone shape data, generated from magnetic resonance imaging (MRI) or computed tomography (CT). The goal of this study was to compare the reproducibility and accuracy of distal femoral torsion (DFT) values measured using these two imaging modalities. We hypothesized that MRI does not reproducibly and consistently measure DFT and is not as accurate as CT scan.

Methods

Anonymized radiology records from 54 patients that included MRI and CT scans of the knee were read in random order by two observers, on two separate occasions. These records were from patients being considered for a meniscal or osteochondral graft and who had their knee explored, but who had not undergone femoral or tibial surgery and were free of osteoarthritis. The DFT was estimated using the posterior condylar angle (PCA), using both its anatomical and surgical definitions. The intra- and inter-observer reproducibility of the MRI and the differences relative to CT scan measurements were analysed.

Results

The average intra-observer difference for the MRI evaluation of the anatomical PCA was 0.8±1.2°; it was 0.4±0.9° for the surgical PCA. More than 1° difference from the average was found in 8 cases (14%) using the anatomical PCA measurement and 4 cases (7.4%) when using the surgical PCA (P=0.4). The intraclass correlation coefficients (ICCs) were 0.67 (95% CI: 0.33–0.85) and 0.74 (95% CI: 0.47–0.89) for the anatomical and surgical PCA, respectively. The average inter-observer difference for the MRI evaluation of the anatomical PCA was 1.6±1.4°; it was 1.5±1.0° for the surgical PCA. More than 1° difference from the average was found in 27 cases (50%) using the anatomical PCA measurement and 22 cases (40%) when using the surgical PCA (P=0.4). The ICCs were 0.31 (95% CI: 0.14–0.65) and 0.48 (95% CI: 0.06–0.75) for the anatomical and surgical PCA, respectively. The average differences between the CT and MRI measurements were 1.4±1.1° (0.2–5°) and 1.1±0.8° (0–3.6°) for the anatomical and surgical PCA, respectively. Greater than 1° difference between CT and MRI was found in 29 records (54%) for the anatomical PCA and in 18 records (33%) for the surgical PCA (P=0.03).

Conclusion

DFT measurement on MRI is more reproducible and consistent when using the surgical PCA. MRI measurements differed by more than 1° relative to CT measurements in more than one-third of cases.

Case control study

Level III.

El texto completo de este artículo está disponible en PDF.

Keywords : Distal femoral torsion, MRI, CT scan, Patient-specific instrumentation, Total knee arthroplasty


Esquema


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 8

P. 937-940 - décembre 2015 Regresar al número
Artículo precedente Artículo precedente
  • Small diameter metal-on-metal total hip arthroplasty at 13 years – a follow-up study
  • N. Tardy, A. Maqdes, P. Boisrenoult, P. Beaufils, P. Oger
| Artículo siguiente Artículo siguiente
  • Cruciate-sacrificing total knee arthroplasty and insert design: A radiologic study of sagittal laxity
  • B. Appy Fedida, E. Krief, E. Havet, P. Massin, P. Mertl

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.