Suscribirse

Combined application of ultrasound and SPECT/CT has incremental value in detecting parathyroid tissue in SHPT patients - 10/02/16

Doi : 10.1016/j.diii.2015.08.007 
L.L. Yuan a, Y. Kan a, D.Q. Ma b, , J.G. Yang a
a Capital Medical University, Beijing Friendship Hospital, Department of Nuclear Medicine, 95, Yong An Road, Xi Cheng district, 100050 Beijing, People's Republic of China 
b Capital Medical University, Beijing Friendship Hospital, Radiology Department, 95, Yong An Road, Xi Cheng district, 100050 Beijing, People's Republic of China 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

The goal of this study is to investigate whether combined application of ultrasound and 99mTc-sestamibi SPECT/CT had the incremental value in accurately detecting parathyroid tissue in patients with SHPT over either method alone.

Patients and methods

Sixty patients with SHPT on hemodialysis were evaluated preoperatively with parathyroid 99mTc-sestamibi SPECT/CT scintigraphy and ultrasound prior to parathyroidectomy. The sensitivity, specificity and accuracy of 99mTc-sestamibi SPECT/CT scintigraphy, ultrasound and combined application were determined respectively.

Results

The sensitivity, specificity and accuracy of ultrasound were 81% (155/192), 47% (17/36) and 82% (172/228), respectively. The sensitivity, specificity and accuracy of 99mTc-sestamibi SPECT/CT were 85% (163/192), 58% (21/36) and 89% (184/228) respectively. The accuracy of 99mTc-sestamibi SPECT/CT in the diagnosis of parathyroid tissue in patients with SHPT is significantly higher than that of ultrasound. The sensitivity, specificity and accuracy of combined application of ultrasound and 99mTc-sestamibi SPECT/CT were 93% (178/192), 61% (22/36) and 97% (200/228). The sensitivity, specificity and accuracy of combined application of ultrasound and 99mTc-sestamibi SPECT/CT were higher than those of either ultrasound or 99mTc-sestamibi SPECT/CT.

Conclusions

The combined application of ultrasound and 99mTc-sestamibi SPECT/CT had incremental value in accurately detecting parathyroid tissue in patients with SHPT over either method alone.

El texto completo de este artículo está disponible en PDF.

Keywords : SPECT/CT, Ultrasound, Secondary hyperparathyroidism, 99mTc-sestamibi, Chronic kidney disease


Esquema


© 2015  Éditions françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 2

P. 219-225 - février 2016 Regresar al número
Artículo precedente Artículo precedente
  • Academic productivity of French radiology residents: Where do we stand?
  • G. Chassagnon, V. Dangouloff-Ros, V. Vilgrain, M. Ronot
| Artículo siguiente Artículo siguiente
  • Multidetector-row computed tomography (MDCT) features of small bowel obstruction (SBO) caused by Meckel's diverticulum
  • Y. Won, H.W. Lee, Y.M. Ku, S.L. Lee, K.J. Seo, J.I. Lee, J.H. Chung

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.