Suscribirse

Reconstruction plates for midshaft clavicular fractures: A retrospective cohort study - 13/02/16

Doi : 10.1016/j.otsr.2015.11.008 
S. Woltz a, , 1 , J.W. Duijff a, 1, J.M. Hoogendoorn b, S.J. Rhemrev b, R.S. Breederveld c, I.B. Schipper a, F.J.P. Beeres d
a Leiden University Medical Center, Leiden, The Netherlands 
b Medical Center Haaglanden, The Hague, The Netherlands 
c Red Cross Hospital, Beverwijk, The Netherlands 
d Luzerner Kantonsspital, Luzern, Switzerland 

Corresponding author. Leiden University Medical Center, Department of Surgery-Traumatology, P.O. box 9600, 2300 RC Leiden, The Netherlands. Tel.: +31 71 529 9166, +31 61 480 4915.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

For the fixation of displaced midshaft clavicular fractures different plates are available, each with its specific pros and cons. The ideal plating choice for this lesion remains subject to ongoing discussion. Reconstruction plates are cheap and easily bendable, but their strength and stability have been questioned. The aim of this study was to evaluate the failure rate of reconstruction plates in the fixation of clavicular fractures.

Materials and methods

A multicenter, retrospective cohort study of all consecutive patients with a displaced, midshaft clavicular fracture (Robinson type 2a/2b) treated with a 3.5-mm reconstruction plate between 2006 and 2013 were evaluated. The primary outcome measure was reoperation rate due to implant failure. Secondary outcome measures were nonunion, symptomatic malunion and elective plate removal.

Results

One hundred and eleven patients were analyzed. During a median follow-up of 8 months, 14 patients (12.6%) had implant failure, of which 7 (6.3%) required a reoperation. Three nonunions (2.7%) and no symptomatic malunions occurred. Plate removal was indicated in 37.8% of patients because of implant irritation.

Discussion

The incidence of reoperation due to implant failure following clavicular plate fixation with a reconstruction plate is 6.3%. Although comparison with other plate types is difficult since rates in literature vary greatly, reoperation rates in other plates are reported around 2–3%, suggesting that reconstruction plates have a higher incidence of implant failure warranting reoperation. Therefore, especially in patients with known risk factors for complications (e.g. smoking, osteoporosis, comminuted fractures), a stronger plate than a reconstruction plate should be considered.

Level of evidence

Level IV. Retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Clavicular fracture, Reconstruction plate, Implant failure, Reoperation


Esquema


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 1

P. 25-29 - février 2016 Regresar al número
Artículo precedente Artículo precedente
  • Total shoulder arthroplasty for proximal humerus fracture is associated with increased hospital charges despite a shorter length of stay
  • A. Manoli, C.E. Capriccioso, S.R. Konda, K.A. Egol
| Artículo siguiente Artículo siguiente
  • Acute high-grade acromioclavicular joint injuries treatment: Arthroscopic non-rigid coracoclavicular fixation provides better quality of life outcomes than hook plate ORIF
  • L. Natera-Cisneros, J. Sarasquete-Reiriz, A. Escolà-Benet, J. Rodriguez-Miralles

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.