Abstract

Background

Kinematic alignment for total knee arthroplasty (TKA) may be one way of improving outcomes. Previous studies have either used patient-specific instrumentation, which adds cost, or standard instrumentation, which provides no intraoperative feedback on resection alignment.

Hypothesis

To determine if computer navigation could reproduce native patient anatomy and simplify ligament balance during TKA whilst giving satisfactory improvements in functional scores at early follow-up.

Materials and methods

Computer navigation was used for kinematic distal femoral and proximal tibial cuts in 100 consecutive and unselected TKAs. Resections were modified only if measured angles fell outside a pre-defined safe range of combined coronal orientation within±3 degrees of neutral and/or independent femoral or tibial cuts within±5 degrees. Pre- and postoperative measurements of the hip-knee-ankle (HKA) angle, the lateral distal femoral angle (LDFA) and the medial proximal tibial angle (MPTA) were taken using long-leg standing radiographs. Clinical evaluation was with the WOMAC and KOOS scales.

Results

Mean follow-up was 2.4 years (range 1.0–3.7, SD 0.8). The mean pre-op LDFA was 2.1 degrees valgus (9.2 valgus to 3.7 varus, SD 2.5) and 1.8 degrees valgus post-op (5.7 valgus to 4.2 varus, SD 2.0) (P=0.41). The mean pre-op MPTA was 3.0 degrees varus (10.6 valgus to 10.2 varus, SD 3.2) and 2.4 degrees varus post-op (4.0 valgus to 6.8 varus, SD 2.2) (P=0.03). The mean WOMAC score improved from 49.4 (29–85, SD 12.8) to 24.7 (0–73, SD 16.5) (P<0.001) and the mean KOOS score from 37.1 (7.2–77.2, SD 13.0) to 65.1 (26.8–100, SD 16) (P<0.001). Five knees (5%) required additional ligament release, four with valgus OA and one with varus OA. Two knees (2%) required lateral retinacular release for patellar tracking.

Discussion

Computer navigation for kinematic TKA provides the operating surgeon with full control and feedback at each step, whilst also allowing partial correction of more extreme anatomy that might be unsuitable for recreation during TKA. This technique helps to preserve ligament isometry and produces satisfactory improvements in functional scores.

Level of evidence

IV (retrospective case series review).

El texto completo de este artículo está disponible en PDF.

Keywords : Knee Arthroplasty, Navigation, TKA, Technique, Outcomes, Kinematic


Esquema


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 1

P. 99-104 - février 2016 Regresar al número
Artículo precedente Artículo precedente
  • Side-to-side variation in normal femoral morphology: 3D CT analysis of 122 femurs
  • D. Dimitriou, T.-Y. Tsai, B. Yue, H.E. Rubash, Y.-M. Kwon, G. Li
| Artículo siguiente Artículo siguiente
  • There is no such thing like a single ACL injury: Profiles of ACL-injured patients
  • R. Seil, C. Mouton, A. Lion, C. Nührenbörger, D. Pape, D. Theisen

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.