Suscribirse

Four-part fractures treated with a reversed total shoulder prosthesis: Prospective and retrospective multicenter study. Results and complications - 25/04/16

Doi : 10.1016/j.otsr.2016.01.019 
L. Obert a, , R. Saadnia a, C. Tournier b, N. Bonnevialle c, D. Saragaglia d, F. Sirveaux e

La SOFCOTf

a Chirurgie orthopédique, traumatologique et plastique, centre hospitalier de Besançon, 2, boulevard Fleming, 25030 Besançon, France 
b Service d’orthopédie-traumatologie, place Amélie-Raba-Léon, 33076 Bordeaux cedex, France 
c Centre hospitalier universitaire de Toulouse, Institut de l’appareil locomoteur, place du Dr-Baylac, 31059, Toulouse, France 
d Service d’orthopédie-traumatologie, CHRU de Grenoble, 38000 Grenoble, France 
e Service d’orthopédie-traumatologie, centre chirurgical E.-Galle, 49, rue Hermite, 54000 Nancy, France 
f Société française de chirurgie orthopédique et traumatologie, 56, rue Boissonnade, 75014 Paris, France 

Corresponding author, Chirurgie orthopédique, traumatologique et plastique, centre hospitalier de Besançon, 2, boulevard Fleming, 25030 Besançon, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The reversed shoulder prosthesis is becoming the gold standard for cases of complex fracture of the proximal humerus after 70 years of age.

Material and methods

The French Society of Orthopaedic and Traumatology Surgery (SOFCOT) conducted a prospective and retrospective multicenter study to evaluate the results of the reversed shoulder prosthesis implanted in patients with a four-part fracture in nine centers. In the retrospective study (n=41 patients, 78 years of age, 14% ASA grade 3, 21% associated fractures) and in the prospective study (n=32 patients, 79 years of age, 37% ASA grade 3, 21% associated fractures) evaluation by independent surgeons was conducted to measure the QuickDASH score, the Constant score, the SSV (subjective shoulder value), and complications to correlate these measurements with radiological results.

Results

In both studies, use of an autograft (75%) to perform an osteosuture of tuberosities (90%) and no postoperative immobilization (75%) were similar. In the retrospective study at 39 months (range: 24–62 months) of follow-up, the QuickDASH reached 28 (range: 0–59), the Constant scores (raw Constant=57, weighted Constant=83.4%), and SSV 75 (range: 35–100). Complications after the 1st month (7%) were nonunion or ossifications. In the prospective study at 11 months (range: 5–16.5 months) of follow-up, the QuickDASH reached 40 (range: 1–75), the Constant scores 50 (raw Constant) and 74.6% (weighted Constant), and SSV 69 (range: 10–100). Complications after the 1st month (21%) were stiffness and dislocation, with two patients who underwent revision surgery. In both studies, early complications reached 6% (palsy, dislocation).

Conclusion

This double (retrospective and prospective) study confirms the good results with a low level of complications of the reversed implant in cases of fracture but with osteosuture of tuberosities.

El texto completo de este artículo está disponible en PDF.

Keywords : Fractures, Proximal humerus, Four-part fracture, Multicenter study, Reversed prosthesis, Osteosuture, Elderly patients


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 3

P. 279-285 - mai 2016 Regresar al número
Artículo precedente Artículo precedente
  • Marketing the direct anterior approach to the hip: Is the industry overstepping its role?
  • P. Massin, SFHG (Société française de la hanche et du genou, French Hip, Knee Society)
| Artículo siguiente Artículo siguiente
  • Comparison of intramedullary fibular allograft with locking compression plate versus shoulder hemi-arthroplasty for repair of osteoporotic four-part proximal humerus fracture: Consecutive, prospective, controlled, and comparative study
  • H. Chen, X. Ji, Y. Gao, L. Zhang, Q. Zhang, X. Liang, P. Tang

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.