Reproducibility of digital measurements of lower-limb deformity on plain radiographs and agreement with CT measurements - 09/05/16

Doi : 10.1016/j.otsr.2016.02.009 
G. Sorin a, , G. Pasquier b, c, E. Drumez b, d, A. Arnould b, c, H. Migaud b, c, S. Putman b, c
a Département d’orthopédie, CHU de Caen, avenue Côte-de-Nacre, 14000 Caen, France 
b Département de chirurgie orthoépdique et de traumatologie, CHRU de Lille, université de Lille, 59000 Lille, France 
c Service d’orthopédie, hôpital Salengro, CHRU de Lille, place de Verdun, 59037 Lille cedex, France 
d Unité de biostatistiques et d’é́pidémiologie, CHRU de Lille, place de Verdun, 59037 Lille cedex, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Five angles (HKA, HKS, alpha, beta, tibial slope) are used for goniometry in total knee arthroplasty. The reproducibility of the measurement of these angles has been assessed on plain and digitized x-rays, but to our knowledge, this has not been confirmed on x-rays taken on the PACS system and they have not been compared to computed tomography (CT) measurements, the reference for angle measurement. This prospective study aimed to: (1) evaluate the inter- and intrarater reliability of the measurement of these angles on digital x-rays taken on a PACS; (2) determine the agreement of these measurements with those obtained using a CT protocol.

Hypothesis

The measurements of these five angles on digitized radiographs are reproducible and in agreement with CT values.

Material and methods

Forty-two patients suffering from knee osteoarthritis and scheduled for total knee arthroplasty were included in the study. Each patient had a PACS digitized x-ray and a CT intended to produce patient-specific instrumentation (Symbios, Yverdon, Switzerland) including measurements of the angles evaluated. Four senior orthopaedic surgeon-raters measured all the angles twice. Inter- and intrarater reliability was then calculated as well as the agreement between the second measurement of each rater and the CT measurement using interclass correlation and kappa coefficients (data provided as means and 95% confidence intervals).

Results

The inter- and intrarater reliability values were excellent for the HKA, alpha, and beta angles (with, respectively, a coefficient of 0.99 [0.97–0.99], 0.84 [0.76–0.9], and 0.94 [0.86–0.96] interrater reliability and 0.98 [0.96–0.99], 0.86 [0.75–0.92], and 0.65 [0.44–0.8] intrarater reliability). Interrater reliability was low for HKS and tibial slope angles (coefficients all<0.4 for interrater reliability and <0.7 for intrarater reliability). The x-ray/CT agreement was very good for the HKA, alpha, and beta angles (0.81 [0.67–0.99], 0.74 [0.56–0.91], and 0.74 [0.45–0.92], respectively) and low for the HKS and tibial slope angles (all<0.45).

Discussion/conclusion

The HKA, alpha, and beta angles were reproducible for digital radiographs and showed good agreement with CT measurements. HKS and tibial slope angles should be used with greater caution, and other navigation methods or patient-specific instrumentation should be explored.

Level of evidence

Level III, prospective, comparative diagnostic case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Agreement, Reproducibility, PACS, Lower-limb angle, Lower-limb deformity, Knee prosthesis, X-rays, CT scan


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 4

P. 423-428 - juin 2016 Regresar al número
Artículo precedente Artículo precedente
  • EOS-based cup navigation: Randomised controlled trial in 78 total hip arthroplasties
  • N. Verdier, A. Billaud, T. Masquefa, J. Pallaro, T. Fabre, C. Tournier
| Artículo siguiente Artículo siguiente
  • Total knee arthroplasty revision with trabecular tantalum cones: Preliminary retrospective study of 51 patients from two centres with a minimal 2-year follow-up
  • D. Girerd, S. Parratte, A. Lunebourg, F. Boureau, M. Ollivier, G. Pasquier, S. Putman, H. Migaud, J.N. Argenson

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.