Suscribirse

Évaluation d’une plateforme d’orthoptie numérique 3D - 26/05/16

Doi : 10.1016/j.jfo.2016.01.004 
M. Lamard a, b, , S. Ferragut b, c, C. Hugny-Larroque d, J.-L. De Bougrenet De La Tocnaye c, B. Cochener a, b, d
a Université de Bretagne occidentale, 3, rue des Archives, CS 93837, 29238 Brest cedex 3, France 
b LaTIM-Inserm UMR 1101, laboratoire de traitement de l’information médicale, Bat 1, CHU Morvan, 29609 Brest cedex, France 
c Télécom Bretagne, CS 83818, 29238 Brest cedex 3, France 
d Service d’ophtalmologie, centre hospitalier régional universitaire, 5, avenue Foch, 29609 Brest cedex, France 

Auteur correspondant.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Résumé

Objectif

Comparer des tests d’orthoptie classiques avec une nouvelle plateforme d’orthoptie numérique 3DeltaEasy© de la société Orthoptica®.

Matériels et méthodes

Cette étude teste la plateforme d’orthoptie numérique 3D 3DeltaEasy© de la société Orthoptica® et la compare aux tests d’orthoptie usuels correspondants. Cette plateforme est composée d’un ordinateur équipé d’un logiciel dédié, d’un vidéo projecteur, et de lunettes 3D à cristaux liquides. Trois tests ont été comparés : le test de Wirt, la mesure des phories horizontales et verticales, et l’amplitude de fusion horizontale en convergence et en divergence. Cette étude a été réalisée sur 102 patients recrutés au sein du CHRU de Brest.

Résultats

Les résultats montrent une bonne corrélation pour le test de Wirt (coefficient de Spearman : Rho=0,74 ; p<0,0001), les mesures de phories n’ont pas de différence significative en vision intermédiaire et de loin (test de Student apparié ; p=0,46 et p=0,51). L’amplitude de fusion ne montre pas de différence significative en convergence et en divergence en vision de loin (test de Student apparié ; p=0,34 et p=0,94).

Conclusion

Cette plateforme d’orthoptie 3D peut aisément remplacer les tests d’orthoptie testés. À terme, en augmentant le nombre de tests, il sera possible d’en remplacer un grand nombre.

El texto completo de este artículo está disponible en PDF.

Summary

Purpose

To compare standard orthoptic tests with a novel digital 3D orthoptic platform, 3DeltaEasy© from Orthoptica®.

Materials and methods

This study tests the 3D digital orthoptics platform, 3DeltaEasy© from Orthoptica® and compares it to the corresponding standard orthoptic tests. This platform consists of a computer equipped with dedicated software, a video projector and 3D liquid crystal glasses. Three tests were compared: Wirt test, measurement of horizontal and vertical phorias, and the horizontal fusional amplitude in convergence and divergence. A total of 102 subjects, 53 males (52 %) and 49 females (48 %), aged between 9 years and 72 years (mean age 33±16.4 years) were examined at the ophthalmologic department of the Brest Hospital (France) and included in this observational cross-sectional study. Subjects recruited in this study were patients requiring orthoptic screening or therapy. Patients without their optimal visual corrections were excluded. All patients underwent both ophthalmological and orthoptic examination including Wirt fly stereotest with polarizing spectacles, cover tests to evaluate and measure the horizontal and vertical deviation of the lines of sight, horizontal vergence ranges using prism bar and their equivalent tests implemented in the digital 3D orthoptic tests 3DeltaEasy© from Orthoptica®.

Results

All data were processed using MedCalc Statistical Software version 14.12.0 (MedCalc Software bvba, Ostend, Belgium). The main result of this study is that 3DeltaEasy© and the classical Wirt test are correlated (Spearman's coefficient of rank correlation: ρ=0.74; P<0.0001), cover tests are equivalent for intermediate and far vision (paired t-test; P=0.46 and P=0.51), and horizontal and vertical vergence range are comparable for distance vision (paired t-test; P=0.34 and P=0.94).

Conclusion

New digital 3D tools could easily substitute for some orthoptic tests with better ergonomics. Eventually, by increasing the number of tests performed, it could substitute for nearly all tests.

El texto completo de este artículo está disponible en PDF.

Mots clés : Tests orthoptiques, Vision binoculaire, Plateforme 3D

Keywords : Orthoptic test, Binocular vision, 3D platform


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 39 - N° 5

P. 441-448 - mai 2016 Regresar al número
Artículo precedente Artículo precedente
  • Evaluation of the visual function of patients with locked-in syndrome: Report of 13 cases
  • M. Graber, G. Challe, M.F. Alexandre, B. Bodaghi, P. LeHoang, V. Touitou
| Artículo siguiente Artículo siguiente
  • Eiconomètre électronique : tests de mesure présentés sur écran stéréoscopique
  • C. Bourdy, Y. James

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.