Suscribirse

The use of static and dynamic haemodynamic parameters before volume expansion: A prospective observational study in six French intensive care units - 07/06/16

Doi : 10.1016/j.accpm.2015.08.003 
Sébastien Preau a, , Florent Dewavrin b , Vincent Demaeght b , Arnaud Chiche c , Benoît Voisin a , Franck Minacori d , Julien Poissy a , Claire Boulle-Geronimi e , Caroline Blazejewski f , Thierry Onimus a , Alain Durocher a , Fabienne Saulnier a
a Intensive Care Unit, Calmette Hospital, University Hospital of Lille, 59000 Lille, France 
b Intensive Care Unit, General Hospital of Valenciennes, 59300 Valenciennes, France 
c Intensive Care Unit, General Hospital of Tourcoing, 59200 Tourcoing, France 
d Intensive Care Unit, University Hospital of Lomme, 59160 Lomme, France 
e Intensive Care Unit, General Hospital of Douai, 59500 Douai, France 
f Intensive Care Unit, Salengro Hospital, University Hospital of Lille, 59000 Lille, France 

Corresponding author at: Critical care centre, University Hospital of Lille, avenue du Professeur-Emile-Laine, Lille 59037, France. Tel.: +33 3 20 44 40 84; fax: +33 3 20 44 50 94.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 10
Iconografías 1
Vídeos 0
Otros 0

Abstract

Objective

The aim of the present study was to determine the use of static and dynamic haemodynamic parameters for predicting fluid responsiveness prior to volume expansion (VE) in intensive care unit (ICU) patients with systemic inflammatory response syndrome (SIRS).

Methods

We conducted a prospective, multicentre, observational study in 6 French ICUs in 2012. ICU physicians were audited concerning their use of static and dynamic haemodynamic parameters before each VE performed in patients with SIRS for 6 consecutive weeks.

Results

The median volume of the 566 VEs administered to patients with SIRS was 1000mL [500–1000mL]. Although at least one static or dynamic haemodynamic parameter was measurable before 99% (95% CI, 99%–100%) of VEs, at least one them was used in only 38% (95% CI, 34%–42%) of cases: static parameters in 11% of cases (95% CI, 10%–12%) and dynamic parameters in 32% (95% CI, 30%–34%). Static parameters were never used when uninterpretable. For 15% of VEs (95% CI, 12%–18%), a dynamic parameter was measured in the presence of contraindications. Among dynamic parameters, respiratory variations in arterial pulse pressure (PPV) and passive leg raising (PLR) were measurable and interpretable before 17% and 90% of VEs, respectively.

Conclusions

Haemodynamic parameters are underused for predicting fluid responsiveness in current practice. In contrast to static parameters, dynamic parameters are often incorrectly used in the presence of contraindications. PLR is more frequently valid than PPV for predicting fluid responsiveness in ICU patients.

El texto completo de este artículo está disponible en PDF.

Keywords : Intensive care, Sepsis, Inflammation, Systemic inflammatory response syndrome, SIRS, Passive leg raising, Respiratory variations

Abbreviations : CO, CVP, GEDV, ICU, IVCV, PAOP, PLR, SIRS, SV, VE, VPP


Esquema


© 2015  Société française d'anesthésie et de réanimation (Sfar). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 35 - N° 2

P. 93-102 - avril 2016 Regresar al número
Artículo precedente Artículo precedente
  • Vittel criteria for severe trauma triage: Characteristics of over-triage
  • Jean Cotte, Fredrik Courjon, Sébastien Beaume, Bertrand Prunet, Julien Bordes, Cédric N’Guyen, Claire Contargyris, Guillaume Lacroix, Ambroise Montcriol, Eric Kaiser, Eric Meaudre
| Artículo siguiente Artículo siguiente
  • How to rationalize preoperative tests? A method to implement local guidelines successfully
  • Stéphanie Suria, Hakim Harkouk, Alexandre Eghiaian, Grégoire Weil

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.