Short-term comparison of postural effects of three minimally invasive hip approaches in primary total hip arthroplasty: Direct anterior, posterolateral and Röttinger - 20/09/16

Doi : 10.1016/j.otsr.2016.05.003 
S. Van Driessche a, F. Billuart b, , L. Martinez b, H. Brunel b, P. Guiffault c, J. Beldame d, J. Matsoukis c
a Clinique de Montargis, 46, rue de la Quintaine, 45200 Montargis, France 
b Laboratoire d’analyse du mouvement, institut de formation en masso-kinésithérapie « Saint-Michel », 68, rue du Commerce, 75015 Paris, France 
c Département de chirurgie orthopédique, groupe hospitalier du Havre, BP 24, 76083 Le Havre cedex, France 
d Clinique Mégival, 1328, avenue de la Maison-Blanche, 76550 Saint-Aubin-sur-Scie, France 

Corresponding author. Tel.: +33 0 662133951.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

There is renewed interest in total hip arthroplasty (THA) with the development of minimally invasive approaches. The anterior and Röttinger approaches are attractive for their anatomical and minimally invasive character, but with no comparative studies in the literature definitely suggesting superiority in terms of quality of functional recovery. We therefore performed a case-control study, assessing: 1) whether the postural parameters of patients operated on with the anterior, Röttinger and posterior minimally invasive approaches were similar to those of asymptomatic subjects, and 2) whether there were any differences in postural parameters between the three approaches at short-term follow-up.

Hypothesis

We hypothesized that the anterior and Röttinger approaches are less disruptive of postural parameters than the posterior approach.

Methods

Seventy subjects (44 primary THA patients and 26 asymptomatic control subjects) were enrolled. Operated subjects were divided into 3 experimental groups corresponding to the 3 minimally invasive approaches: posterior (n=14), anterior (n=15) and Röttinger (n=15). Two single-leg stance tests (left followed by right leg stance; 10s per test) were carried out on a stabilometric platform, within 2months after surgery for all THA patients, and for controls. Six significant parameters were selected for statistical analysis: test performance, mediolateral and anteroposterior displacements of the center of pressure (CP), path length, average CP displacement speed, and the ellipse containing 95% of CP projections. Non-parametric statistical tests were used to compare groups.

Results

There was no difference between the 3 study groups and the control group according to age, gender, BMI, or side (or between study groups regarding WOMAC score). No significant differences between approaches were found for success on postural tests (P=0.14). Subjects operated on with the anterior or Röttinger approach showed significant differences from asymptomatic subjects for 2 postural parameters: path length (Röttinger P=0.04, anterior P=0.03) and average CP displacement speed (Röttinger P=0.04, anterior P=0.03). Subjects operated on through the posterior approach showed no significant differences from asymptomatic subjects.

Discussion

The study hypothesis, that the anterior and Röttinger approaches for hip arthroplasty are less disruptive of postural parameters than the posterior approach, was not confirmed. The anterior and Röttinger approach groups showed higher average CP displacement speed and path length, suggesting that they use up more energy resources to maintain static balance. The posterior approach had the least impact on postural parameters in the first 2 postoperative months.

Level of evidence

III, case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasty, Minimally invasive approaches, Static postural balance


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 6

P. 729-734 - octobre 2016 Regresar al número
Artículo precedente Artículo precedente
  • A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components – a cadaveric study
  • R. Möbius, S. Schleifenbaum, R. Grunert, S. Löffler, M. Werner, T. Prietzel, N. Hammer
| Artículo siguiente Artículo siguiente
  • Is there any range-of-motion advantage to using bearings larger than 36 mm in primary hip arthroplasty: A case-control study comparing 36-mm and large-diameter heads
  • C. Delay, S. Putman, G. Dereudre, J. Girard, V. Lancelier-Bariatinsky, E. Drumez, H. Migaud

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.