Suscribirse

Does a titanium sleeve reduce the frequency of pseudotumors in metal-on-metal total hip arthroplasty at 5–7 years follow-up? - 01/12/16

Doi : 10.1016/j.otsr.2016.08.020 
M.H. Hjorth a, , 1 , N. Egund b, I. Mechlenburg a, c, J. Gelineck b, S.S. Jakobsen a, K. Soballe a, d, M. Stilling d, e
a Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark 
b Department of Radiology, Aarhus University Hospital, Nørrebrogade 44, 8000 Aarhus C, Denmark 
c Centre of Research in Rehabilitation (CORIR), Department of Clinical Medicine, Aarhus University, Denmark 
d Orthopaedic Research Unit, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark 
e Department of Clinical Medicine, Aarhus University, Denmark 

Corresponding author. Tel.: +45 4081 3181; fax: +45 7846 5271.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Little is known about pseudotumor frequency and risk factors for pseudotumor formation among different types of metal-on-metal (MoM) hip arthroplasties. A lower release of chromium and cobalt have been reported in MoM hip arthroplasties with a titanium sleeve compared to MoM designs without a titanium sleeve, but yet it is unknown whether a titanium sleeve reduces the pseudotumor frequency. We conducted a cross-sectional study to investigate: 1) pseudotumor frequency, 2) risk factors of pseudotumor formation 3) and correlations between pseudotumors, serum metal-ions, implant position, and clinical symptoms.

Hypothesis

We expected a lower pseudotumor frequency in MoM hip articulation with a titanium sleeve than reported in MoM hip articulation designs using chromium-cobalt sleeve.

Materials and method

A consecutive series of 41 patients/49 hips (31 males), mean age 52 (28–68) years, participated in a 5.5±0.5 (4–6.5) year follow-up study of their M2a_Magnum hip articulation (Biomet Inc., Warsaw, Indiana, USA). Patients were evaluated with magnetic resonance imaging (MRI), measurements of serum metal-ions, plain radiographs, and clinical outcome measures of Harris Hip Score (HHS) and Oxford Hip Score (OHS).

Results

Eighteen of 47 hips (38%) had MRI-verified pseudotumors, all cystic, with a mean dimension of 10.6×25.6×41mm. Digital measurements on plain radiographs revealed a higher cup anteversion in patients with a pseudotumor of mean 28.4°±5.05° compared to mean 23.5°±6.5° in patients without a pseudotumor (P=0.009). Serum metal-ion concentrations, acetabular cup inclination and measures of HHS and OHS were similar between patients with and without a pseudotumor (P>0.46).

Conclusion

At 5.5±0.5years after surgery, MRI-verified cystic pseudotumors were frequently observed in M2a_Magnum hip articulations despite the use of titanium sleeves. The pseudotumors were related to high cup anteversion angles but not related to high serum metal-ions or clinical symptoms.

Level of evidence

IV: cross-sectional study.

El texto completo de este artículo está disponible en PDF.

Keywords : Titanium sleeve, Metal-on-metal total hip arthroplasty, Magnetic resonance imaging, Pseudotumor, Serum metal-ion levels, Clinical outcome measures


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 8

P. 1035-1041 - décembre 2016 Regresar al número
Artículo precedente Artículo precedente
  • Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement
  • D. Ancelin, N. Reina, E. Cavaignac, S. Delclaux, P. Chiron
| Artículo siguiente Artículo siguiente
  • Small femoral offset is a risk factor for lateral femoral cutaneous nerve injury during total hip arthroplasty using a direct anterior approach
  • Y. Ozaki, Y. Homma, K. Sano, T. Baba, H. Ochi, A. Desroches, M. Matsumoto, T. Yuasa, K. Kaneko

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.