Suscribirse

Fixed-distance walk tests at comfortable and fast speed: Potential tools for the functional assessment of coronary patients? - 15/01/17

Doi : 10.1016/j.rehab.2016.11.001 
Marie-Doriane Morard a, c, Delphine Besson a, c, Davy Laroche a, Alexandre Naaïm a, Vincent Gremeaux a, b, c, Jean-Marie Casillas a, b, c,
a CIC INSERM 1432, Plateforme d’Investigation Technologique, CHU de Dijon, Dijon, France 
b INSERM U1093, Cognition, Action, Plasticité Sensori-motrice, Dijon, France 
c Cardiac Rehabilitation Department, University Hospital of Dijon, Dijon, France 

Corresponding author. Cardiac Rehabilitation Department, CHU Dijon, 23, rue Gaffarel, 21078 Dijon cedex, France. Tel.: +33 3 80 29 38 14; fax: +33 3 80 29 36 43.Cardiac Rehabilitation Department, CHU Dijon, 23, rue Gaffarel, 21078 Dijon cedex, France. Tel.: +33 3 80 29 38 14; fax: +33 3 80 29 36 43.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Objectives

There is ambiguity concerning the walk tests available for functional assessment of coronary patients, particularly for the walking speed. This study explores the psychometric properties of two walking tests, based on fixed-distance tests, at comfortable and fast velocity, in stabilized patients at the end of a cardiac rehabilitation program.

Methods

At a three-day interval 58 coronary patients (mean age of 64.85±6.03 years, 50 men) performed three walk tests, the first two at a comfortable speed in a random order (6-minute walk test – 6MWT – and 400-metre comfortable walk test – 400mCWT) and the third at a brisk speed (200-metre fast walk test – 200mFWT). A modified Bruce treadmill test was associated at the end of the second phase. Monitored main parameters were: heart rate, walking velocity, VO2.

Results

Tolerance to the 3 tests was satisfactory. The reliability of the main parameters was good (intraclass correlation coefficient>0.8). The VO2 concerning 6MWT and 400mCWT were not significantly different (P=0.33) and were lower to the first ventilatory threshold determined by the stress test (P<0.001): 16.2±3.0 vs. 16.5±2.6 vs. 20.7±5.1mL·min−1·kg−1 respectively. The VO2 of the 200mFWT (20.2±3.7) was not different from the first ventilatory threshold.

Conclusions

400mCWT and 200mFWT are feasible, well-tolerated and reliable. They explore two levels of effort intensity (lower and not different to the first ventilatory threshold respectively). 400mCWT is a possible alternative to 6MWT. Associated with 200mFWT it should allow a better measurement of physical capacities and better customization of exercise training.

El texto completo de este artículo está disponible en PDF.

Keywords : Cardiac rehabilitation, Functional test, 400 meter walk test, 6minute walk test, Walking test


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 60 - N° 1

P. 13-19 - janvier 2017 Regresar al número
Artículo precedente Artículo precedente
  • Stress, anxiety and depression in heart disease patients: A major challenge for cardiac rehabilitation
  • Jean-Christophe Chauvet-Gelinier, Bernard Bonin
| Artículo siguiente Artículo siguiente
  • Whole-body strength training with Huber Motion Lab and traditional strength training in cardiac rehabilitation: A randomized controlled study
  • Thibaut Guiraud, Marc Labrunée, Florent Besnier, Jean-Michel Sénard, Fabien Pillard, Daniel Rivière, Lisa Richard, Davy Laroche, Frédéric Sanguignol, Atul Pathak, Mathieu Gayda, Vincent Gremeaux

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.