Suscribirse

Comportement biomécanique des refixations de tubérosité dans les arthroplasties pour fracture proximale de l’humérus - 30/03/17

Biomechanical strength and failure mechanism of different tubercula refixation methods within the framework of an arthroplasty for shoulder fracture

Doi : 10.1016/j.rcot.2016.12.012 
J. Fleischer a, , A. Schleyer b, R. Nassutt c, U. Grittner d, I. Ojodu e, S. Jörg Hopp f
a Marien Hospital, Department of Trauma and Orthopedics, Am Hirschberg, 66606 St. Wendel, Allemagne 
b University Medical Center Schleswig-Holstein, Biomechanics Laboratory, Campus Lübeck, Ratzeburger Allee 160, D-23538 Lübeck, Germany 
c Stryker Trauma, Kiel, Allemagne 
d Charité Medical University, Department for Biostatistics and Clinical Epidemiology, Freie Universität Berlin, Kaiserswerther Str. 16–18, 14195 Berlin, Germany 
e Department of Orthopedic Surgery, Cedarcrest Hospital, Abuja, Nigeria 
f University Hospital of Saarland, Department of Trauma, Hand and Reconstructive Surgery, 66421 Homburg/Saarland, Allemagne 

Auteur correspondant.

Abstract

Background

Tuberosity repair in shoulder fracture prosthesis implantation still remains a challenge often leading to poor functional outcomes, despite a variety of materials and suggested suture patterns. We aimed to evaluate, which forces currently used suture and cerclage materials withstand and to assess whether they are useful with regard to stability of reconstruction of tuberosities and which failure modes they display.

Material and methods

Using sheep infraspinatus tendons with attached tuberosities three different suture materials (suture 1: Ethibond size 2; suture 2: Orthocord size 2; suture 3: Fiberwire size 5) and a 0.8mm titanium cerclage wire were investigated. For each suture material as well as the cerclage wire 6 tests were carried out. A material testing machine was used to perform cyclic loading tests (20mm/min, Fmin=50N, Fmax=100N, respectively after 50 cycles: Fmax+50N until failure). Outcome measures and thus comparison criteria were the maximum holding force, number of cycles reached, total elongation of the system (tendon and suture) and qualitative appraisal and documentation of the mechanism of failure.

Results

Overall average maximum forces between the fixation materials differed significantly (P=0.003), especially suture 3 (braided polyethylene coating, non-resorbable polyfile UHMW core) displayed superior results in comparison to the cerclage wire (P=0.016). Although, primary elongation of the cerclage technique was significantly lower compared to the suture materials (P=0.002). All tests showed a high initial lengthening and caused incision-like defects in the bone or tendon and led to failure and huge displacement of the tuberosities.

Discussion

Currently used suture and cerclage materials have a limited usefulness for refixation of tuberosities due to an increased risk of obstruction for bony consolidation.

Level of evidence

Basic science, biomechanics.

El texto completo de este artículo está disponible en PDF.

Keywords : Biomechanical tests, Tuberosity refixation, Failure mechanism, Shoulder fracture prosthesis, Suture materials



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2016  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 2

P. 121 - avril 2017 Regresar al número
Artículo precedente Artículo precedente
  • Modification de l’angle cervicodiaphysaire huméral lors de la rotation interne et externe de l’épaule : angulation 2D dans un espace 3D
  • A. Adikrishna, H. Hong, M.F. Deslivia, B. Zhu, J. Tan, I.-H. Jeon
| Artículo siguiente Artículo siguiente
  • Traitement des luxations acromioclaviculaires type III selon Rockwood : TightRope® versus brochage. Une étude comparée
  • K. Horst, C. Garving, T. Thometzki, P. Lichte, M. Knobe, T. Dienstknecht, M. Hofman, H.-C. Pape

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.