Suscribirse

Preoperative planning for accurate glenoid component positioning in reverse shoulder arthroplasty - 21/04/17

Doi : 10.1016/j.otsr.2016.12.019 
J. Berhouet a, b, , L.V. Gulotta a, b, D.M. Dines a, E. Craig a, R.F. Warren a, D. Choi c, X. Chen c, A. Kontaxis b
a Hospital for Special Surgery, Department of Sports Medicine and Shoulder, 535 E 70th St., New York, NY 10021, USA 
b Hospital for Special Surgery, The Leon Root, Motion Analysis Laboratory, 510 E 73rd St., New York, NY 10021, USA 
c Hospital for Special Surgery, Biomechanical Laboratory, 510 E 73rd St., New York, NY 10021, USA 

Corresponding author at: Hospital For Special Surgery, Department of Sports Medicine and Shoulder, 535 E 70th St., New York, NY 10021, USA.Hospital For Special Surgery, Department of Sports Medicine and Shoulder535 E 70th St.New YorkNY10021USA

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Glenoid component positioning in reverse shoulder arthroplasty (RSA) is challenging. Patient-specific instrumentation (PSI) has been advocated to improve accuracy, and is based on precise preoperative planning. The purpose of this study was to determine the accuracy of glenoid component positioning when only the glenoid surface is visible, compared to when the entire scapula is visible on a 3D virtual model.

Methods

CT scans of 30 arthritic shoulders were reconstructed in 3D models. Two surgeons then virtually placed a glenosphere component in the model while visualizing only the glenoid surface, in order to simulate typical intraoperative exposure (“blind 3D” surgery). One surgeon then placed the component in an ideal position while visualizing the entire scapula (“visible 3D” surgery). These two positions were then compared, and the accuracy of glenoid component positioning was assessed in terms of correction of native glenoid version and tilt, and avoidance of glenoid vault perforation.

Results

Mean version and tilt after “blind 3D” surgery were +1.4° (SD 8.8°) and +7.6° (SD 6°), respectively; glenoid vault perforation occurred in 17 specimens. Mean version and tilt after “visible 3D” surgery were +0.3° (SD 0.8°) and +0.1° (SD 0.5°), respectively, with glenoid vault perforation in 6 cases. “Visible 3D” surgery provided significantly better accuracy than “blind 3D” surgery (P<0.05).

Conclusion

When the entire scapula is used as reference, accuracy is improved and glenoid vault perforation is less frequent. This type of visualization is only possible with pre-operative 3D CT planning, and may be augmented by PSI.

Level of evidence

Basic science study. Level III.

El texto completo de este artículo está disponible en PDF.

Keywords : Reverse shoulder arthroplasty, Glenoid component positioning, Accuracy, CT-assisted surgery, Preoperative planning, Patient-specific instrumentation


Esquema


© 2017  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 3

P. 407-413 - mai 2017 Regresar al número
Artículo precedente Artículo precedente
  • Hawkins’ type-II talar fracture with subtalar dislocation: A very unusual combination
  • R. Gérard, N. Kerfant, G. Dubois de Mont Marin, R. Stern, M. Assal
| Artículo siguiente Artículo siguiente
  • Results and limitations of humeral head resurfacing: 105 cases at a mean follow-up of 5 years
  • K. Soudy, C. Szymanski, C. Lalanne, C. Bourgault, A. Thiounn, A. Cotten, C. Maynou

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.