Prospective ECG-gated high-pitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities: Radiation dose and diagnostic efficacy in a pediatric population - 11/05/17

Doi : 10.1016/j.diii.2016.03.014 
M. Koplay a, , O. Kizilca b, D. Cimen c, M. Sivri a, H. Erdogan a, O. Guvenc c, M. Oc d, B. Oran c
a Department of Radiology, Medical Faculty, Selcuk University, Konya, Turkey 
b Department of Radiology, Horasan Government Hospital, Erzurum, Turkey 
c Department of Pediatric Cardiology, Medical Faculty, Selcuk University, Konya, Turkey 
d Department of Cardiovascular Surgery, Medical Faculty, Selcuk University, Konya, Turkey 

Corresponding author at: Department of Radiology, Medical Faculty, Selcuk University, The Central Campus, 42075 Konya, Turkey.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

The goal of this study was to investigate the radiation dose and diagnostic efficacy of cardiac computed tomography angiography (CCTA) using prospective ECG-gated high-pitch dual-source computed tomography (DSCT) in the diagnosis of congenital cardiovascular abnormalities in pediatric population.

Materials and methods

One hundred five pediatric patients who were clinically diagnosed with congenital heart disease with suspected extracardiac vascular abnormalities were included in the study. All CCTAs were performed on a 128×2-section DSCT scanner. CCTA findings were compared with surgical and/or conventional cardiac angiography findings. Dose-length product (DLP) and effective doses (ED) were calculated for each patient. Patients were divided into 4 groups by age, and ED and DLP values were compared among groups. The image quality was evaluated using a five-point scale.

Results

CCTA showed 173 abnormalities in 105 patients. There were 2 patients with false positive and 3 with false negative findings. The sensitivity and specificity of CCTA were 98.3% and 99.9%, respectively. The positive predictive value and negative predictive value of CCT were 98.9% and 99.9%, respectively. The average DLP and ED values were 15.6±9.6 (SD) mGy.cm and 0.34±0.10 (SD) mSv, respectively. The mean image quality score was 4.8±0.5 (SD) in all patients. The inter-observer agreement for the image quality scores was good (κ=0.80).

Conclusion

CCTA is an excellent imaging modality for evaluation of cardiovascular abnormalities and provides excellent image quality with very low radiation exposure when low-dose prospective ECG-triggered high-pitch DSCT is used.

El texto completo de este artículo está disponible en PDF.

Keywords : Cardiovascular, Congenital, Prospective ECG-triggered, Cardiac CT, Dual-source CT


Esquema


© 2016  Editions françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 11

P. 1141-1150 - novembre 2016 Regresar al número
Artículo precedente Artículo precedente
  • Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image quality
  • F. Macri, J. Greffier, F.R. Pereira, C. Mandoul, E. Khasanova, G. Gualdi, J.P. Beregi
| Artículo siguiente Artículo siguiente
  • Correlation between primary flat foot and lower extremity rotational misalignment in adults
  • A. Cebulski-Delebarre, N. Boutry, C. Szymanski, C. Maynou, G. Lefebvre, E. Amzallag-Bellenger, A. Cotten

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.