Can a target zone safer than Lewinnek's safe zone be defined to prevent instability of total hip arthroplasties? Case-control study of 56 dislocated THA and 93 matched controls - 18/08/17

Doi : 10.1016/j.otsr.2017.05.015 
N. Reina a, , S. Putman b, R. Desmarchelier c, E. Sari Ali d, P. Chiron a, M. Ollivier e, J.Y. Jenny f, D. Waast g, C. Mabit h, E. de Thomasson i, C. Schwartz j, P. Oger k, L.E. Gayet l, H. Migaud b, N. Ramdane m, M.H. Fessy c

SFHG1

  Société française de chirurgie de la hanche et du genou, 52, rue Boissonade, Paris, France.

a Institut locomoteur (ILM), hôpital Pierre-Paul-Riquet, CHU de Toulouse, 31059 Toulouse, France 
b Hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France 
c Service de chirurgie orthopédique et traumatologique, hospices civils de Lyon, centre hospitalier Lyon-Sud, université de Lyon, 69002 Pierre-Bénite, France 
d Service de chirurgie orthopédique et traumatologique, hôpital la Pitié-Salpétrière, 47-83, boulevard de l’Hôpital, 75013 Paris, France 
e Service de chirurgie orthopédique et traumatologique, hôpital St. Marguerite, 13009 Marseille, France 
f Service de chirurgie orthopédique et traumatologique, hôpital de Hautepierre, CHU de Strasbourg, 67091 Strasbourg, France 
g Service de chirurgie orthopédique et traumatologique, Hôtel-Dieu, 1, place Alexis-Ricordeau, 44093 Nantes, France 
h Service de chirurgie orthopédique et traumatologique, CHU Dupuytren, avenue M.-Luther-King, CHU de Limoges, 87000 Limoges, France 
i Institut mutualiste Montsouris, 42, boulevard Jourdan, 75014 Paris, France 
j Centre d’orthopédie clinique des 3-frontières, 68300 Saint-Louis, France 
k Hopital A.-Mignot, 177, route De-Versailles, 78150 Le Chesnay, France 
l Service de chirurgie orthopédique et traumatologique, CHU de Poitiers, 86021 Poitiers, France 
m Unité de biostatistique, pôle de santé publique, CHRU de Lille, 59000 Lille, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Various factors contribute to instability of total hip arthroplasty (THA), with implant orientation being a major contributor. We performed a case-control study with computed tomography (CT) data to determine whether: 1) orientation contributes to THA instability and 2) a safer target zone for stability than Lewinnek's classic safe zone can be defined.

Material and methods

We included prospectively 363 cases of THA dislocation that occurred during the calendar 2013 year in 24 participating hospitals. Of the 128 dislocations that occurred in patients who underwent THA at these centers, 56 (24 anterior, 32 posterior) had CT scans, thus were included in the analysis. The control group was matched 4:1 based on implant type, year of implantation, age, sex, bearing types and THA indication. Of the 428 matched control THA cases, 93 had CT scans. In all, the CT scans from 149 cases (56 unstable, 93 stable) were analyzed to determine the acetabular cup's inclination and anteversion, and the femoral stem's anteversion.

Results

In the unstable THA group, cup inclination was 46.9°±7.4°, cup anteversion was 20.4°±10.8° and stem anteversion was 14.2°±9.9°. In the stable THA group, cup inclination was 44.9°±5.3° (P=0.057), cup anteversion was 22.1°±5.1° (P=0.009) and stem anteversion was 13.4°±4.4° (P=0.362). The optimal total anteversion (cup+stem) of 40–60° was achieved in 16.5% of unstable THA cases and 13.9% of stable THA cases, thus this parameter does not predict stability (odds ratio [OR] of 0.40, P=0.144). The cup was positioned in Lewinnek's safe zone in 44.6% of patients in the unstable group and 68.2% of those in the stable group (OR 3.74, P=0.003). A target zone defined as 40–50° inclination and 15–30° anteversion was better able to distinguish between unstable cases (23.2%) and stable cases (71.6%) resulting in an OR of 13.91 (P<0.001).

Discussion

Implant positioning was the only risk factor for instability found in this study. Moreover, our findings reinforce the theory put forward by other authors that Lewinnek's safe zone is not specific enough to differentiate between stable and unstable THA implantations. The target zone for acetabular cups proposed here (40–50° inclination and 15°–30° anteversion) is related to a lower risk of instability. This orientation can be used as a guide, but must be combined with other technical elements to optimize stability. By balancing stability and biomechanics, the 40–50° inclination and 15°–30° anteversion target zone redefines the optimal positioning window.

Level of evidence

III case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : THA, Dislocation, Safe zone, Approach


Esquema


 Work of the French Hip & Knee Society (SFHG).


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 5

P. 657-661 - septembre 2017 Regresar al número
Artículo precedente Artículo precedente
  • Hip-spine syndrome: A cadaveric analysis between osteoarthritis of the lumbar spine and hip joints
  • D.S. Weinberg, J.J. Gebhart, R.W. Liu
| Artículo siguiente Artículo siguiente
  • What are the risk factors for dislocation in primary total hip arthroplasty? A multicenter case-control study of 128 unstable and 438 stable hips
  • M.H. Fessy, S. Putman, A. Viste, R. Isida, N. Ramdane, A. Ferreira, A. Leglise, B. Rubens-Duval, N. Bonin, F. Bonnomet, A. Combes, S. Boisgard, D. Mainard, S. Leclercq, H. Migaud, SFHG 1

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.