Abstract

Background

There is no universally accepted approach to the elbow for the fixation of coronoid process fractures. This study aims to introduce a novel anterior surgical approach for the fixation of the ulnar coronoid fracture, with minimal surgical dissection damage and excellent visualization for reduction and internal fixation.

Hypothesis

The anterior approach can facilitate satisfactory outcomes for coronoid process fractures.

Material and methods

From February 2010 to July 2014, 12 patients (8 males and 4 females; range 14–62years; mean age 31years) with a closed fracture of the coronoid process of the ulna were included in this study. According to Adams classification, we included 5 type II, 3 type III, 3 type IV AM, and 1 type IV AL. The fractures were treated operatively via an anterior approach between nerves and blood vessels. The anatomical reduction and fixation with cannulated screws or a mini plate was easily performed. One elbow showed significant joint instability, necessitating, another incision to repair the lateral collateral ligament, and a subsequent operation with a hinged external fixator was required. The remaining patients received a splint for 2 weeks followed by functional exercises.

Results

Mean follow-up was 21 months (13–36). Fracture union was achieved in each patient. The arc of elbow flexion and extension were (135±15)°, and forearm pronation/supination were restored to (165±15)°. When compared with the normal side, there was no significant difference in the functional outcome (P>0.05). According to Morrey’ scale, the functional recovery of the injured arms was assessed as excellent in eleven patients and good in one. Mild heterotopic ossification was found in one case, which had not impaired the elbow function. No other complications were noted.

Conclusions

The anterior approach has the benefits of simplicity, safety, minimal invasion, excellent exposure, and satisfactory prognosis for coronoid process fractures.

Level of evidence

Prospective study, Level IV.

El texto completo de este artículo está disponible en PDF.

Keywords : Elbow, Coronoid process, Fracture, Anterior approach, Space between nerves and blood vessels, Internal fixation


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 6

P. 899-904 - octobre 2017 Regresar al número
Artículo precedente Artículo precedente
  • First-line management of distal humerus fracture by total elbow arthroplasty in geriatric traumatology: Results in a 21-patient series at a minimum 2 years’ follow-up
  • D. Lami, M. Chivot, A. Caubere, A. Galland, J.N. Argenson
| Artículo siguiente Artículo siguiente
  • Non-operative treatment of displaced distal radius fractures leads to acceptable functional outcomes, however at the expense of 40% subsequent surgeries
  • M.A.M. Mulders, P.V. van Eerten, J.C. Goslings, N.W.L. Schep

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.