Suscribirse

Tunnel positioning assessment after anterior cruciate ligament reconstruction at 12 months: Comparison between 3D CT and 3D MRI. A pilot study - 16/09/17

Doi : 10.1016/j.otsr.2017.06.005 
E. Ducouret a, P. Loriaut b, P. Boyer b, A. Perozziello c, L. Pesquer d, C. Mounayer e, B. Dallaudiere d, f, g,
a Département de radiologie, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges, France 
b Département de chirurgie orthopédique, CHU Bichat, 48, rue Henri-Huchard, 75018 Paris France 
c Laboratoire de biostatistiques, CHU Bichat, 48, rue Henri-Huchard, 75018 Paris, France 
d Centre d’imagerie ostéoarticulaire, clinique du sport, Bordeaux Mérignac, 2, rue Georges-Négrevergne, 33700 Mérignac, France 
e Département de neuroradiologie interventionnelle, CHU Dupuytren, 2, avenue Martin-Luther-King, 87042 Limoges, France 
f Service de radiologie, département d’imagerie musculo-squelettique, CHU Pellegrin, place Amélie-Léon-Rabat, 33000 Bordeaux, France 
g Centre de résonance magnétique des systèmes biologiques, UMR 5536, CNRS, université de Bordeaux, 146, rue Léo-Saignat, 33076 Bordeaux, France 

Corresponding author. CHU Pellegrin, MSK Imaging Department, place Amélie-Léon-Rabat, Bordeaux, 33000, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Tunnel positioning assessment is a major issue after anterior cruciate ligament (ACL) reconstruction surgery. Historically, it used plain X-ray and, more recently, CT with 3D reconstruction. MRI is a reliable method of assessing ACL graft integrity and postoperative complications. To our knowledge, there have been no studies of efficacy in tunnel positioning assessment. The aim of this study was to assess the efficacy of 3D MRI in assessing femoral and tibial tunnel positioning after ACL reconstruction. The hypothesis was that 3D MRI sequences with reconstruction are as accurate as 3D CT for tunnel positioning assessment in ACL reconstruction.

Methods

Twenty-two patients who underwent an arthroscopic ACL reconstruction using hamstring graft were included in a prospective study. All patients were examined on 3D CT and 3D MRI at 12months post-surgery. Tunnel positioning was assessed on both imaging systems by a musculoskeletal radiologist and an orthopedic surgeon specialized in knee arthroscopy, both blind to all clinical data.

Results

No statistically significant difference was found between 3D CT and 3D MRI on coronal and sagittal reconstructions. For coronal assessment of tibial tunnel orifice, sagittal assessment of tibial tunnel orifice and sagittal assessment of femoral tunnel orifice, P-values ranged from 0.37 to 0.99, 0.051 to 0.64 and 0.19 to 0.59, respectively. For tibial and femoral tunnel angulation, P-values were respectively 0.52 and 0.29.

Conclusion

3D MRI is a reliable method to assess femoral and tibia tunnel positioning in ACL reconstruction, compared to 3D CT as gold standard. Indeed, in our opinion 3D MRI could in the future replace CT for ACL reconstruction assessment, concerning not only the meniscus and ligaments but also tunnel position.

Level of evidence

Level 3; comparative prospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : CT-scan, MRI, Anterior cruciate ligament, Transplant


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 6

P. 937-942 - octobre 2017 Regresar al número
Artículo precedente Artículo precedente
  • Acute finger-tip infection: Management and treatment. A 103-case series
  • F. Rabarin, J. Jeudy, B. Cesari, A. Petit, N. Bigorre, Y. Saint-Cast, P.-A. Fouque, G. Raimbeau, Orthopedics and Traumatology Society of Western France (SOO) 1
| Artículo siguiente Artículo siguiente
  • High failure rate of anterior cruciate ligament reconstruction with bimeniscal repair: A case-control study
  • H. Gonçalves, C. Steltzlen, P. Boisrenoult, P. Beaufils, N. Pujol

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.